Han Zhang

Dr. Han Zhang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
HZHan Zhang
Han Zhang
ZWZiyi Wang
Ziyi Wang
YZYan Zhuang
Yan Zhuang
SYShimin Yin
Shimin Yin
ZCZhengcheng Chen
Zhengcheng Chen
YLYongbo Liang
Yongbo Liang
Mental workload is an important predisposing factor for mental illnesses such as depression and is closely related to individual mental health. However, the suboptimal accuracy of utilizing photoplethysmography (PPG) exclusively for mental workload classification has constrained its application within pertinent professional domains. To this end, this paper proposes a signal processing method that combines continuous wavelet transform (CWT) and cardiopulmonary coupling mapping (CPC) to classify mental load via a convolutional neural network (ResAttNet). The method reflects changes in mental workload, as assessed by changes in the association between heart rate variability and respiration. In this paper, the strengths and weaknesses of this method are compared with other traditional psychological workload monitoring methods, such as heart rate variability (HRV), and its validation is performed on the publicly available dataset MAUS. The experiments show that the method is significantly better than previous machine learning methods based on heart rate variability correlation. Meanwhile, the accuracy of the method proposed in this paper reaches 80.5%, which is 6.2% higher than in previous studies. It is comparable to the result of 82.4% for the ECG-based mental workload monitoring system. Therefore, the method of combining CWT and CPC has considerable potential and provides new ideas for mental workload classification.

24 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GRGuihao Ran
Guihao Ran
YWYijing Wang
Yijing Wang
HZHan Zhang
Han Zhang
JCJiahui Cheng
Jiahui Cheng
Dakun LaiDakun Lai
Dakun Lai
Electrocardiogram (ECG) and phonocardiogram (PCG) signals are widely used in the early prevention and diagnosis of cardiovascular diseases (CVDs) due to their ability to accurately reflect cardiac conditions from different physiological perspectives and their ease of acquisition. Currently, some studies have explored the joint use of ECG and PCG signals for disease screening, but few studies have considered the trade-off between classification performance and energy consumption in model design. In this study, we propose a multimodal CVDs detection framework based on Spiking Neural Networks (SNNs), which integrates ECG and PCG signals. A differential fusion strategy at the signal level is employed to generate a fused EPCG signal, from which time–frequency features are extracted using the Adaptive Superlets Transform (ASLT). Two separate Spiking Convolutional Neural Network (SCNN) models are then trained on the ECG and EPCG signals, respectively. A confidence-based dynamic decision-level (CDD) fusion strategy is subsequently employed to perform the final classification. The proposed method is validated on the PhysioNet/CinC Challenge 2016 dataset, achieving an accuracy of 89.74%, an AUC of 89.08%, and an energy consumption of 209.6 μJ. This method not only achieves better balancing performance compared to unimodal signals but also realizes an effective balance between model energy consumption and classification effect, which provides an effective idea for the development of low-power, multimodal medical diagnostic systems.

3 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GRGuihao Ran
Guihao Ran
SLShengzhe Li
Shengzhe Li
ZJZhiwen Jiang
Zhiwen Jiang
HZHan Zhang
Han Zhang
XLXinyuan Long
Xinyuan Long
Dakun LaiDakun Lai
Dakun Lai
The aim of this study is to propose an uncertainty-aware dynamic cascading framework based on spiking neural network (UDC-SNN) for multimodal emotion recognition, particularly to address the inherent trade-off between recognition performance and energy efficiency. An asymmetric dynamic routing mechanism was proposed to enable demand-driven activation of the high-power electroencephalogram (EEG) branch, coupled with preliminary inference on a low-power electrocardiogram (ECG) branch and uncertainty quantification via Shannon entropy. Meanwhile, a parameter-free log-linear aggregation strategy was developed to transform modality-specific entropy into dynamic Bayesian weights through an exponential decay function, effectively mitigating the negative transfer effects induced by unimodal noise. The UDC-SNN was evaluated on the multimodal affective dataset DREAMER, comprising 23 subjects (170,660 segments). The averaged recognition accuracy and energy consumption across the three dimensions of valence, arousal, and dominance were 90.75% and 4.62 μJ, respectively. The obtained results suggest that the proposed framework could potentially achieve a favorable balance between high emotion recognition and low energy consumption, thereby establishing its applicability for real-time monitoring in resource-constrained scenarios.

2 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HZHan Zhang
Han Zhang
XHXudong Hu
Xudong Hu
XZXizhuang Zhang
Xizhuang Zhang
ZCZhengcheng Chen
Zhengcheng Chen
YLYongbo Liang
Yongbo Liang
GWGang Wang
Gang Wang
Hypertension is a major risk factor for cardiovascular disease and requires effective long-term monitoring. Photoplethysmography (PPG), acquired from wearable optical sensors, offers a convenient and non-invasive signal source for cuffless blood pressure (BP) estimation, but existing studies have mainly emphasized model architecture optimization, with limited systematic investigation of signal representation. This study systematically compares seven one-dimensional-to-two-dimensional signal transformation methods and evaluates multiple architectural variants for PPG-based cuffless BP estimation under a unified framework. Experiments were conducted using PPG and arterial BP signals from the UCI Open Blood Pressure Database. The best-performing configuration, based on continuous wavelet transform (CWT), achieved estimation errors of 3.80 ± 5.02 mmHg for systolic BP and 1.65 ± 2.70 mmHg for diastolic BP. Further real-world validation on 26 participants using an Omron cuff-based monitor as the reference showed good consistency, with correlation coefficients of R = 0.96 for SBP and R = 0.74 for DBP. The results demonstrate that appropriate signal representation, particularly CWT, plays a critical role in improving estimation accuracy and robustness, and may facilitate the development of wearable cuffless BP monitoring systems.