Kerry Sado

Dr. Kerry Sado

electrical engineering, University of South Carolina, Columbia, Connecticut, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Kerry SadoKerry Sado
Kerry Sado
JPJarrett Peskar
Jarrett Peskar
ADAustin Downey
Austin Downey
JKJamil Khan
Jamil Khan
KBKristen Booth
Kristen Booth
The ability to forecast system conditions is integral to the definition and functionality of digital twins. While forecasting methods have been explored for use in digital twin systems, the integration of feedback mechanisms for real-time forecasting and in-situ decision-making in DC microgrids has not been extensively investigated. This research develops a modular forecasting framework tailored for digital twins in DC microgrids to enable real-time monitoring, online forecasting, and decision-making. DC microgrids, characterized by dynamic load variations, benefit from advanced predictive capabilities to maintain stability and operational efficiency. The proposed digital twin-based forecasting framework addresses these challenges by providing real-time predictive insights based on dynamic system conditions and a forecasting window defined by a decision-maker, facilitating proactive management strategies. Leveraging real-time sensor data, the digital twin forecasts system behavior under varying load conditions, enabling proactive management through real-time decision-making within operational constraints. As a proof of concept, the framework incorporates an electro-thermal digital twin designed to manage power flow based on thermal constraints in power distribution cables. Experimental validation using a simplified three-bus DC microgrid testbed demonstrates the effectiveness of the framework in enabling timely adjustments to power flows and preventing thermal overloads.

10 February 2021 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Kerry SadoKerry Sado
Kerry Sado
LHLokman H. Hassan
Lokman H. Hassan
SSShivan Sado
Shivan Sado
The tilt angle of solar panels is significant for capturing solar radiation that reaches the surface of the panel. Photovoltaic (PV) performance and efficiency are highly affected by its angle of tilt with respect to the horizontal plane. The amount of radiation reaching the surface of a PV panel changes with the changes in its tilt angle, hence adding a solar tracking system will maximize the amount of solar radiation reaching the surface of a PV panel at any time during the day, however, integrating solar tracking system will increase the total cost and maintenance of any PV system. Thus, using an optimized fixed tilt angle is the solution to element the initial, maintenance, and operation costs of a solar tracking system. Yet, the fixed angle is location-specific because it depends on the daily, monthly, and yearly location of the sun. In this study; daily, monthly and seasonally angles are calculated mathematically and the amount of incident radiation on the surface of the PV panel is measured along with its voltage. By comparing the practical measurements of the output voltage of PV panels, an optimized tilt angle is decided.

8 July 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Open access
Kerry SadoKerry Sado
Kerry Sado
JPJarrett Peskar
Jarrett Peskar
Austin DowneyAustin Downey
Austin Downey
HGHerbert L. Ginn
Herbert L. Ginn
RDRoger Dougal
Roger Dougal
KBKristen Booth
Kristen Booth
Digital twin capabilities have been limited to a single function, but the reality of physical assets requires digital twins with multi-domain, multi-function representations. Digital twins can and should be designed with multi-domain and multi-functional capabilities to enable adaptability to a diverse set of system domains and perform various representation tasks. This approach allows the digital twin to be as specialized as the physical asset it serves. This study introduces a framework enabling the development of multi-domain, multi-functional digital twins, adaptable for use in various representation tasks. The proposed framework utilizes a collection of digital images for an accurate depiction of different facets of an asset, ensuring a detailed yet unified digital twin. The framework is designed to analyze the human-in-the-loop text-based query and select the most suitable digital image for execution. The proposed multi-domain, multi-function digital twin framework reduces the computational effort by 5.15% when compared to a single, unified digital twin running all studies concurrently. Details on the development of the framework are provided, and experimental results validate the effectiveness of the proposed framework.

8 December 2018 in Academic Journal of Nawroz University
Verified
Journal Article
Open access
PDF file
Kerry SadoKerry Sado
Kerry Sado
LHLokman H. Hassan
Lokman H. Hassan
The agriculture sector nowadays relies mostly on conventional energy sources and traditional irrigation ways. Considering some factors such as high costs of fossil fuels and providing new power lines, especially to remote locations and where grid electricity is either inaccessible or expensive, a solar PV powered irrigation system can be a practical choice for irrigating crop fields. In this paper, a PV-powered dc water pump system design for irrigation is presented. A comprehensive comparison between Direct Current (DC) and an Alternative Current (AC) motors powered by PV is carried out in terms of power, current, water discharge and cost. Dominant factors of the system such as the effect of solar radiation on motor power, current, and water discharge are considered in this study. The optimum tilt angle for Duhok city is considered to perform this study. The specifications of PV, DC and AC motors are tested in Matlab Simulink to show the performance of the system components. The results show that DC motor is preferred over AC in term of system complexity, cost and power consumption. In contrast, water discharge of AC pump is slightly higher than the DC pump for the same time. However, overall results demonstrate the superiority of DC motor over AC.

1 September 2018
Verified
Conference Paper
Closed access
Kerry SadoKerry Sado
Kerry Sado
LHLokman H. Hassan
Lokman H. Hassan
Mahmoud MoghavvemiMahmoud Moghavvemi
Mahmoud Moghavvemi
A PV-powered automatic irrigation system is designed and implemented in this paper. Dominant factors of the system such as the effect of solar radiation on motor power, current, and water discharge are considered in this study. The proposed system is implemented in the field to irrigate corn plant (maize) considering the optimum tilt angle for Duhok city. A new method for measuring the moisture content in the soil and sufficient level of moisture needed for normal growth of the crop is presented to design a timer for the system to reduce the amount of wasted water. Moisture sensors are used to check the availability of water in the soil and to enable the microcontroller to control the operation status of the pump. The results show that the proposed irrigation method is more accurate and efficient than the conventional irrigation methods in terms of the amount of the water used for irrigation, and the accuracy of irrigating times based on changing local climate. The results clearly demonstrate that the proposed system is more cost effective way of irrigation and more environmental friendly in terms of the amount of water used in an area known for water scarcity.

13 April 2026 in IEEE Access
Verified
Journal Article
Open access
JWJosiah N. Worch
Josiah N. Worch
Kerry SadoKerry Sado
Kerry Sado
Austin DowneyAustin Downey
Austin Downey
JKJamil A. Khan
Jamil A. Khan
ESEnrico Santi
Enrico Santi
Power electronic systems in autonomous vehicles and mission-critical applications are highly susceptible to overheating due to operational inefficiencies. These systems often rely on liquid cooling loops to maintain safe temperatures. However, blockages in cooling loops can lead to temperature rises, component degradation, and eventual system failure. This paper presents a digital twin (DT) approach that enables early detection of coolant-loop blockages and provides a framework for developing autonomous rectification of cooling loop blockages using only temperature sensors. The proposed method integrates transient and steady-state thermal models to detect anomalies and predict system behavior in real-time. A robust detection logic, comprising five independent threshold-based switches, identifies deviations from normal behavior while avoiding false positives. Experimental validation is conducted using a physical testbed to evaluate performance under varying blockage conditions. The system detects blockages in less than 1 min, with temperatures remaining roughly 25 °C below the maximum operating temperature of 80 °C, well within safe operating limits. This approach eliminates the need for additional sensing hardware and is well suited to embedded and remote applications.