Team Experimental Advanced Superconducting Tokamak
+1
The spatial and temporal evolutions of compound sawteeth were directly observed using 2D electron cyclotron emission imaging on experimental advanced superconducting tokamak. The compound sawtooth consists of partial and full collapses. After partial collapse, the hot core survives as only a small amount of heat disperses outwards, whereas in the following full collapse a large amount of heat is released and the hot core dissipates. The presence of two q = 1 surfaces was not observed. Instead, the compound sawtooth occurs mainly at the beginning of an ion cyclotron resonant frequency heating pulse and during the L-H transition phase, which may be related to heat transport suppression caused by a decrease in electron heat diffusivity.
Saturated sawtooth oscillations of the (1,1) mode and its higher harmonics are observed in ELMy H-mode discharges at the EAST facility. Their spatial and temporal characteristics are ascertained using singular value decomposition (SVD) and short-time Fourier transform (STFT). In non-NBI heating discharges, partial collapse is detected during the mid-precursor stage of sawtooth oscillations when the minimum safety factor (qmin) is ≤1. However, in NBI heating discharges, higher harmonic modes are detected during the precursor and collapse phases of the sawtooth when qmin ≥ 1. Furthermore, these mode patterns are developed at the onset of NBI heating, during which the plasma exhibits a gradual decrease in poloidal beta (βp) and electron temperature, along with a loss of fast ions due to ELM activity. However, the ion temperature remains unchanged due to the continuous effect of NBI heating. These saturated modes are susceptible to quasi-interchange instabilities, influenced by the hybrid operational mode of the EAST facility, which is characterized by qmin ≥ 1, low core magnetic shear, and high-pressure gradients. These experimental findings are consistent with interchange instability theories and previous numerical studies, particularly in conditions where qmin ≥ 1 and higher harmonic modes are critical in sawtooth collapse. However, these modes deviate from the predictions of the Kadomtsev model.
Electron Cyclotron Emission Imaging (ECEI) is a diagnostic system which measures 2-D electron temperature profiles with high spatial-temporal resolution. Usually only the normalized electron temperature fluctuations are utilized to investigate the magnetohydrodynamics modes due to the difficulties of ECEI calibration. In this paper, we developed a self-dependent calibration method for 24 × 16 channel high-resolution ECEI on the Experimental Advanced Superconducting Tokamak. The technique of shape matching is applied to solve for the matrix of the calibration coefficients. The calibrated area is further expanded to an occupation ratio of 88% observation area by utilizing the features of sawtooth crash. The result is self-consistent and consistent with calibrated 1D ECE measurement.