The aim of this study was to evaluate audiological characteristics and parents’ opinions on hearing device use in children with unilateral sensorineural hearing loss (USNHL) who attended a tertiary-level audiologic center. The medical charts of 70 children aged 6 to 12 years with USNHL were reviewed. In 51.4% of cases, the children were diagnosed with USNHL after the age of 2 years. The main causes of USNHL were congenital cytomegalovirus infection (21.4%) and unilateral cochlear nerve hypoplasia (12.9%). The percentage of patients wearing a hearing device was 45.7% (32/70); of these, 28 (87.5%) wore a conventional hearing aid, 2 (6.3%) a CROS device, and 2 (6.3%) a cochlear implant. Regarding the choice to use a hearing device, no significant differences were found between the subcategories of hearing loss degree (p = 0.55) and audiometric configuration (p = 0.54). Most parents of children with mild-to-severe USNHL observed improved attention (90.9%), and reduced fatigue and restlessness (86.4%) using the hearing aid. These children performed significantly better on all audiological tests (speech perception in quiet and in noise conditions, and sound localization) while wearing the hearing aid (p < 0.001). More efforts should be made to raise awareness among professionals and parents about the negative consequences of uncorrected USNHL.
Introduction: Acceptable Noise Level (ANL) is defined as the most comfortable level (MCL) intensity for speech and is calculated by subtracting the maximum noise tolerable by an individual. The ANL test has been used over time to predict hearing aid use and the impact of digital noise reduction. This study analyzes this impact by using different masker babble spectra when performing the ANL test in both hearing-impaired and healthy subjects in three different languages (Dutch, French, and Italian). Materials and Methods: A total of 198 patients underwent the ANL test in their native language using a standardized protocol. The babble file was speech-weighted to match the long-term spectrum of the specific ANL language version. ANL was proposed in three different masking conditions: with multitalker Matched babble speech noise, with the same masking signal with the spectrum reduced from 2 kHz onwards (High Cut), and with the spectrum increased from 2 kHz onwards (High Boost). Results: In all of the comparisons among the three languages, ANL with High Boost noise gave significantly higher (worse) scores than ANL with Matched noise (p-value S1: <0.0001, S2: <0.0001, S3: 0.0003) and ANL with High Cut noise (p-value S1: 0.0002, S2: <0.0001, S3: <0.0001). The ANL values did not show any significant correlation with age and gender. In French, a weak correlation was found between ANL with High Cut noise and the Fletcher index of the worst ear. In Italian, a weak correlation was found between both ANL with Matched and High Boost noise and the Fletcher index of the best ear. Conclusions: ANL with High Boost added to noise stimuli was less acceptable for all patients in all of the languages. The ANL results did not vary in relation to the patients’ characteristics. This study confirms that the ANL test has potential application for clinical use regardless of the native language spoken.
Background/Objectives: Sequential bilateral cochlear implantation is being increasingly considered in paediatric patients with bilateral profound hearing loss, particularly when the contralateral ear shows limited residual hearing or poor speech discrimination. Although auditory benefits of a second cochlear implant (CI2) have been reported, concerns remain regarding possible vestibular impairment after surgery. This study aimed to provide a preliminary prospective evaluation of early audiological and vestibular outcomes in children undergoing sequential bilateral cochlear implantation and to explore whether the age at implantation or the inter-implant interval influenced longitudinal trajectories. Methods: Ten children with prelingual bilateral profound sensorineural hearing loss who underwent sequential bilateral cochlear implantation were prospectively enrolled. Assessments were performed at baseline and during follow-up up to 12 months after CI2 activation. The audiological evaluation included pure-tone audiometry, speech recognition in quiet with CI2 alone and bilaterally, and speech-in-noise testing in frontal and lateralised configurations. The vestibular evaluation included static stabilometry and video head impulse testing. Patient-reported outcomes were assessed using the speech, spatial and qualities of hearing scale for children. Longitudinal changes were analysed using mixed-effects models with false discovery rate correction. Results: Unilateral speech recognition with CI2 improved significantly over time, with median word recognition increasing from 0% at 3 months to 60% at 12 months (p < 0.0001; q = 0.0001). The speech-in-noise performance also improved significantly in the frontal and F1C configurations. Bilateral speech recognition in quiet remained stable at high levels, consistent with a ceiling effect. The vestibular measures were broadly stable at the group level, and the SSQ scores showed modest, non-significant changes. Exploratory analyses did not identify consistent effects of the implantation age or inter-implant interval on longitudinal trajectories. Conclusions: Sequential bilateral cochlear implantation was associated with early auditory benefit, particularly for CI2 unilateral performance and speech perception in noise, without evidence of major short-term vestibular deterioration.