Valerio Maria Di Pasquale Fiasca

Valerio Maria Di Pasquale Fiasca


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2026 in Audiology Research
Verified
Journal Article
Open access
PDF file
VFValerio Maria Di Pasquale Fiasca
Valerio Maria Di Pasquale Fiasca
ANAlfredo Gabriele Nanni
Alfredo Gabriele Nanni
MPMarco Pozzi
Marco Pozzi
LCLorenzo Collino
Lorenzo Collino
BMBarbara Martino
Barbara Martino
FBFederica Di Berardino
Federica Di Berardino
Background: Objective assessment of postural control is central to the clinical evaluation of vestibular disorders. Although force-platform-based posturography is considered the gold standard, its use may be limited by cost and infrastructural requirements. Wearable inertial measurement units (IMUs) represent a promising alternative; however, their clinical validation should account for intrinsic differences in measurement paradigms rather than strict metric equivalence. Objective: To preliminarily evaluate the within-session reliability of a wearable IMU-based medical device for balance assessment (Gravity), and its agreement with established static (SBP) and computerised dynamic posturographic systems (CDP) in healthy subjects. Methods: Sixty-three healthy adults were enrolled in two independent method comparison studies: a wearable IMU-based balance system versus a static stabilometric platform (GRAVITY vs. SVEP; n = 42) and a wearable IMU-based balance system versus computerised dynamic posturography (Gravity vs. EquiTest; n = 21). Gravity measurements were obtained simultaneously with reference systems across standardised sensory conditions. Within-session reliability and method agreement were assessed. Results: Within-session reliability of Gravity was outcome-dependent. Length-based components demonstrated higher repeatability (ICC (single) = 0.25–0.35; ICC (average) = 0.41–0.52), with narrower limits of agreement (LoA = ±9–12%) and lower measurement error (SEM = 3.3–4.3%). In comparison with SBP, length-based measures exhibited narrower limits (LoA = ±12–17) and more consistent relationships. Comparison with CDP revealed moderate agreement for composite and preferential scores (LoA: −2.20–7.07; −5.54–8.12). Conclusions: Gravity sensor may represent a clinically meaningful, outcome-dependent performance, with superior reliability and comparability for length-based postural measures compared with area-based measures. The device could provide balance assessments compatible with both static and dynamic posturographic systems, accounting for physiological variability. These findings support the potential clinical use of wearable IMU-based posturography, particularly in settings where conventional force-platform systems are not readily available, and warrant further validation in larger, more clinically diverse populations.

1 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Francesco ComacchioFrancesco Comacchio
Francesco Comacchio
ACArianna Comacchio
Arianna Comacchio
FBFederica Di Berardino
Federica Di Berardino
VFValerio Maria Di Pasquale Fiasca
Valerio Maria Di Pasquale Fiasca
Background: Persistent Postural Perceptual Dizziness (PPPD) unifies several preceding diagnoses that share persistent non-vertiginous dizziness and visually or posturally triggered unsteadiness. Whether clinically meaningful subtypes exist within PPPD remains debated. We aim to characterise demographic, clinical, and psychological profiles of untreated PPPD patients and test for differences across subtypes corresponding to historical entities: Chronic Subjective Dizziness (CSD), Phobic Postural Vertigo (PPV), Space Motion Discomfort (SMD), and Visual Vertigo (VV). Methods: Retrospective observational study of consecutive PPPD patients evaluated in a single neurotology practice (2023–2025). All underwent standard vestibular work-up, symptom profiling, and psychological assessment (Beck Anxiety Inventory, Beck Depression Inventory-II, and clinician-rated attitudes). Results: Eighty-eight patients (mean age 40 years; female predominance) met PPPD criteria. PPV was most frequent (>two-thirds), followed by CSD. Instability predominated (54%), whereas dizziness was less common (19%), indicating mainly postural disturbance. Subtyping showed attitude differences (p=0.0006): SMD/VV patients more often displayed obsessive attitudes and less frequent anxious attitudes, while PPV patients were less often obsessive and more often anxious. Anxiety and depression scores did not differ significantly across subtypes. SMD/VV was strongly linked to acute vestibular triggers (all unilateral vestibular neuritis), whereas CSD frequently occurred without prior vestibular disease. Psychosocial triggers and prior psychiatric diagnoses clustered in specific subgroups. Conclusions: PPPD could be considered a heterogeneous spectrum with subtype-specific clinical–psychological profiles. Integrating subgroup profiling and systematic psychological assessment may guide personalised treatment, prioritising cognitive–behavioural strategies for obsessive/visual profiles and vestibular rehabilitation for postural-dominant presentations; longitudinal studies should validate tailored pathways and refine prognostic stratification.

29 May 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
FBFederica Di Berardino
Federica Di Berardino
MPMarco Pozzi
Marco Pozzi
AGAnna Maria Gasbarre
Anna Maria Gasbarre
VCValeria Castelli
Valeria Castelli
CLCinzia Lazzarini
Cinzia Lazzarini
VFValerio Maria Di Pasquale Fiasca
Valerio Maria Di Pasquale Fiasca
Background/Objectives: Sequential bilateral cochlear implantation is being increasingly considered in paediatric patients with bilateral profound hearing loss, particularly when the contralateral ear shows limited residual hearing or poor speech discrimination. Although auditory benefits of a second cochlear implant (CI2) have been reported, concerns remain regarding possible vestibular impairment after surgery. This study aimed to provide a preliminary prospective evaluation of early audiological and vestibular outcomes in children undergoing sequential bilateral cochlear implantation and to explore whether the age at implantation or the inter-implant interval influenced longitudinal trajectories. Methods: Ten children with prelingual bilateral profound sensorineural hearing loss who underwent sequential bilateral cochlear implantation were prospectively enrolled. Assessments were performed at baseline and during follow-up up to 12 months after CI2 activation. The audiological evaluation included pure-tone audiometry, speech recognition in quiet with CI2 alone and bilaterally, and speech-in-noise testing in frontal and lateralised configurations. The vestibular evaluation included static stabilometry and video head impulse testing. Patient-reported outcomes were assessed using the speech, spatial and qualities of hearing scale for children. Longitudinal changes were analysed using mixed-effects models with false discovery rate correction. Results: Unilateral speech recognition with CI2 improved significantly over time, with median word recognition increasing from 0% at 3 months to 60% at 12 months (p < 0.0001; q = 0.0001). The speech-in-noise performance also improved significantly in the frontal and F1C configurations. Bilateral speech recognition in quiet remained stable at high levels, consistent with a ceiling effect. The vestibular measures were broadly stable at the group level, and the SSQ scores showed modest, non-significant changes. Exploratory analyses did not identify consistent effects of the implantation age or inter-implant interval on longitudinal trajectories. Conclusions: Sequential bilateral cochlear implantation was associated with early auditory benefit, particularly for CI2 unilateral performance and speech perception in noise, without evidence of major short-term vestibular deterioration.