Marco Pozzi

Dr. Marco Pozzi


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2026 in Audiology Research
Verified
Journal Article
Open access
PDF file
FLFrancesco Lazzerini
Francesco Lazzerini
FFFrancesca Forli
Francesca Forli
SBSTEFANO BERRETTINI
STEFANO BERRETTINI
FBFederica Di Berardino
Federica Di Berardino
MPMarco Pozzi
Marco Pozzi
Diego ZanettiDiego Zanetti
Diego Zanetti
Cochlear implantation (CI) effectively restores hearing across the whole lifespan but may be followed by vestibular complaints, especially in adult recipients. The aim of this narrative review is to provide a comprehensive characterization of vestibular complaints after CI in adults, collecting clinical and instrumental data, as well as discussing the risk factors for their development. From data reported in the literature, we defined five recurring clinical presentations of postoperative vestibular disturbances (phenotypes): acute postoperative vestibular syndrome, benign paroxysmal positional vertigo (BPPV), delayed Ménière-like vertigo attributable to secondary endolymphatic hydrops, chronic postoperative disequilibrium, and stimulation-linked vertigo. According to the different pathogeneses underlying each presentation, the management of postoperative vestibular complaints should be phenotype-guided, including short-course vestibular suppressants and early mobilisation for acute presentations; canalith repositioning for BPPV; empiric therapy for hydropic-like episodes; and vestibular rehabilitation when imbalance is persistent, programming changes for stimulation-linked symptoms. Alongside this phenotype-driven approach, subjective symptoms are common across cohorts but are usually transient and persistent disability is uncommon. Furthermore, instrumental data across the studies indicate that objective abnormalities cluster in otolith and low-frequency canal measures: Cervical, ocular VEMP, and caloric responses are more often impaired than high-frequency canal function on vHIT, confirming histopathological studies showing preferential saccular involvement during the insertion of the electrode array. The risk of postoperative vestibular complaints not only appears to be modulated more by patient-related factors, especially pre-existing vestibular loss, but also by the aetiology of deafness, or age, rather than by device characteristics; atraumatic surgical approaches may further reduce this risk. This review emphasizes that future research on vestibular complaints after CI should adopt standardized phenotypes when evaluating symptoms, objective vestibular function, falls, and quality of life. Additionally, it should correlate these outcomes with hypothetical risk factors and detailed surgical reports.

17 March 2026 in Audiology Research
Verified
Journal Article
Open access
PDF file
VFValerio Maria Di Pasquale Fiasca
Valerio Maria Di Pasquale Fiasca
ANAlfredo Gabriele Nanni
Alfredo Gabriele Nanni
MPMarco Pozzi
Marco Pozzi
LCLorenzo Collino
Lorenzo Collino
BMBarbara Martino
Barbara Martino
FBFederica Di Berardino
Federica Di Berardino
Background: Objective assessment of postural control is central to the clinical evaluation of vestibular disorders. Although force-platform-based posturography is considered the gold standard, its use may be limited by cost and infrastructural requirements. Wearable inertial measurement units (IMUs) represent a promising alternative; however, their clinical validation should account for intrinsic differences in measurement paradigms rather than strict metric equivalence. Objective: To preliminarily evaluate the within-session reliability of a wearable IMU-based medical device for balance assessment (Gravity), and its agreement with established static (SBP) and computerised dynamic posturographic systems (CDP) in healthy subjects. Methods: Sixty-three healthy adults were enrolled in two independent method comparison studies: a wearable IMU-based balance system versus a static stabilometric platform (GRAVITY vs. SVEP; n = 42) and a wearable IMU-based balance system versus computerised dynamic posturography (Gravity vs. EquiTest; n = 21). Gravity measurements were obtained simultaneously with reference systems across standardised sensory conditions. Within-session reliability and method agreement were assessed. Results: Within-session reliability of Gravity was outcome-dependent. Length-based components demonstrated higher repeatability (ICC (single) = 0.25–0.35; ICC (average) = 0.41–0.52), with narrower limits of agreement (LoA = ±9–12%) and lower measurement error (SEM = 3.3–4.3%). In comparison with SBP, length-based measures exhibited narrower limits (LoA = ±12–17) and more consistent relationships. Comparison with CDP revealed moderate agreement for composite and preferential scores (LoA: −2.20–7.07; −5.54–8.12). Conclusions: Gravity sensor may represent a clinically meaningful, outcome-dependent performance, with superior reliability and comparability for length-based postural measures compared with area-based measures. The device could provide balance assessments compatible with both static and dynamic posturographic systems, accounting for physiological variability. These findings support the potential clinical use of wearable IMU-based posturography, particularly in settings where conventional force-platform systems are not readily available, and warrant further validation in larger, more clinically diverse populations.

29 May 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
FBFederica Di Berardino
Federica Di Berardino
MPMarco Pozzi
Marco Pozzi
AGAnna Maria Gasbarre
Anna Maria Gasbarre
VCValeria Castelli
Valeria Castelli
CLCinzia Lazzarini
Cinzia Lazzarini
VFValerio Maria Di Pasquale Fiasca
Valerio Maria Di Pasquale Fiasca
Background/Objectives: Sequential bilateral cochlear implantation is being increasingly considered in paediatric patients with bilateral profound hearing loss, particularly when the contralateral ear shows limited residual hearing or poor speech discrimination. Although auditory benefits of a second cochlear implant (CI2) have been reported, concerns remain regarding possible vestibular impairment after surgery. This study aimed to provide a preliminary prospective evaluation of early audiological and vestibular outcomes in children undergoing sequential bilateral cochlear implantation and to explore whether the age at implantation or the inter-implant interval influenced longitudinal trajectories. Methods: Ten children with prelingual bilateral profound sensorineural hearing loss who underwent sequential bilateral cochlear implantation were prospectively enrolled. Assessments were performed at baseline and during follow-up up to 12 months after CI2 activation. The audiological evaluation included pure-tone audiometry, speech recognition in quiet with CI2 alone and bilaterally, and speech-in-noise testing in frontal and lateralised configurations. The vestibular evaluation included static stabilometry and video head impulse testing. Patient-reported outcomes were assessed using the speech, spatial and qualities of hearing scale for children. Longitudinal changes were analysed using mixed-effects models with false discovery rate correction. Results: Unilateral speech recognition with CI2 improved significantly over time, with median word recognition increasing from 0% at 3 months to 60% at 12 months (p < 0.0001; q = 0.0001). The speech-in-noise performance also improved significantly in the frontal and F1C configurations. Bilateral speech recognition in quiet remained stable at high levels, consistent with a ceiling effect. The vestibular measures were broadly stable at the group level, and the SSQ scores showed modest, non-significant changes. Exploratory analyses did not identify consistent effects of the implantation age or inter-implant interval on longitudinal trajectories. Conclusions: Sequential bilateral cochlear implantation was associated with early auditory benefit, particularly for CI2 unilateral performance and speech perception in noise, without evidence of major short-term vestibular deterioration.