Heavy metal poisoning has a life-threatening impact on the human body to aquatic ecosystems. This necessitates designing a convenient green methodology for the fabrication of an electrochemical sensor that can detect heavy metal ions efficiently. In this study, boron (B) and nitrogen (N) co-doped laser-induced porous graphene (LIGBN) nanostructured electrodes were fabricated using a direct laser writing technique. The fabricated electrodes were utilised for the individual and simultaneous electrochemical detection of lead (Pb2+) and cadmium (Cd2+) ions using a square wave voltammetry technique (SWV). The synergistic effect of B and N co-doping results in an improved sensing performance of the electrode with better sensitivity of 0.725 µA/µM for Pb2+ and 0.661 µA/µM for Cd2+ ions, respectively. Moreover, the sensing electrode shows a low limit of detection of 0.21 µM and 0.25 µM for Pb2+ and Cd2+ ions, with wide linear ranges from 8.0 to 80 µM for Pb2+ and Cd2+ ions and high linearity of R2 = 0.99 in case of simultaneous detection. This rapid and facile method of fabricating heteroatom-doped porous graphene opens a new avenue in electrochemical sensing studies to detect various hazardous metal ions.
The threats posed by environmental pollution caused by heavy metals and pesticides, affecting ecosystems and human health, demand the on-site monitoring of these pollutants using sensitive electrochemical methods. In this work, we fabricated affordable and efficient hybrid ZnO–porous graphene (ZnGrp) nanostructures from waste-derived cork using a simple and feasible direct laser writing technique. The successful fabrication of hybrid ZnGrp was confirmed via microscopic and spectroscopic analyses. Under optimal conditions, the ZnGrp nanostructured hybrid was utilized as an electrode material for the square wave anodic stripping voltammetry (SWASV) analysis of cadmium (Cd2+) and lead (Pb2+) ions in a 0.1 M acetate buffer solution. The calculated limits of detection (LODs) for Cd2+ and Pb2+ are 2.08 nM and 1.28 nM in a linear range of 1–25 μM, and the sensitivity values of ZnGrp for these ions are 5.83 μM μA−1 and 6.21 μM μA−1, respectively. The ZnGrp electrode accurately detects Cd2+ and Pb2+ in a linear range of 1–14 μM for spiked sea water samples, with a recovery rate of nearly 100%. Furthermore, the ZnGrp electrode was utilized for the SWASV analysis of paraquat (PQ) in 0.1 M phosphate buffer solution (PBS) and the spiked wash water of Amaranthus leaves. Moreover, the LOD was found to be 0.09 μM in PBS in a linear range of 1–15 μM PQ. The standard addition calibration plot displays two linear ranges, a low-concentration range (2–6 μM) and a high-concentration range (6–15 μM), exhibiting a recovery rate of approximately 100%. The fabricated hybrid electrode is selective, reproducible and stable towards the real-time sensing of Cd, Pb and PQ.