Yuhan Ahan

Ms. Yuhan Ahan


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SWShengnan Wu
Shengnan Wu
NLNanfei Lv
Nanfei Lv
YAYuhan Ahan
Yuhan Ahan
XCXiaolu Chen
Xiaolu Chen
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
Sailing HeSailing He
Sailing He
In this paper, an optical fiber Fabry–Pérot (FP) microfluidic sensor based on the capillary fiber (CF) and side illumination method is designed. The hybrid FP cavity (HFP) is naturally formed by the inner air hole and silica wall of CF which is side illuminated by another single mode fiber (SMF). The CF acts as a naturally microfluidic channel, which can be served as a potential microfluidic solution concentration sensor. Moreover, the FP cavity formed by silica wall is insensitive to ambient solution refractive index but sensitive to the temperature. Thus, the HFP sensor can simultaneously measure microfluidic refractive index (RI) and temperature by cross-sensitivity matrix method. Three sensors with different inner air hole diameters were selected to fabricate and characterize the sensing performance. The interference spectra corresponding to each cavity length can be separated from each amplitude peak in the FFT spectra with a proper bandpass filter. Experimental results indicate that the proposed sensor with excellent sensing performance of temperature compensation is low-cost and easy to build, which is suitable for in situ monitoring and high-precision sensing of drug concentration and the optical constants of micro-specimens in the biomedical and biochemical fields.

26 March 2024 in Photonics
Verified
Journal Article
Open access
PDF file
YAYuhan Ahan
Yuhan Ahan
TZTie Zhang
Tie Zhang
SWShengnan Wu
Shengnan Wu
Sailing HeSailing He
Sailing He
Laser absorption spectroscopy for gas sensing basically employs an air pump located at the gas cell probe to draw in ambient gases, and the on-site gas sample is subsequently delivered for laboratory non-real-time analysis. In this study, an in situ all-fiber remote gas sensing strategy is proposed. The anti-resonant hollow-core fiber (AR-HCF) is used as the sensing fiber, and a 20 m middle-hole eccentric-core fiber (MH-ECF) is used as the conducting fiber. The remote ambient gases can be inhaled into the AR-HCF as a result of the negative pressure transmitted through the MH-ECF when pumping gas at the interface of the MH-ECF. Since the real-time monitoring of greenhouse gas emissions in industrial processes holds immense significance in addressing global climate change, the detection of CO2 is achieved with the TDLAS-WMS method, and the gas sensing performance of an all-fiber remote gas sensing structure (RGS) is experimentally validated. The response time t90 under the pumping condition is about 456 s, which is about 30 times faster than that of free diffusion. Allan deviation results for more than one hour of continuous monitoring indicate that the lowest detection limit for the all-fiber RGS is 0.0373% when the integration time is 184 s. The all-fiber remote gas sensing strategy also possesses the benefits of being applicable to multiplex, hazardous gas environment passive monitoring.