We investigate the magnetic field-dependent fluorescence lifetime of microdiamond powder containing a high density of nitrogen-vacancy centers. This constitutes a non-intensity quantity for robust, all-optical magnetic field sensing. We propose a fiber-based setup in which the excitation intensity is modulated in a frequency range up to . The change in magnitude and phase of the fluorescence relative to is recorded where the phase shows a maximum in magnetic contrast of at . A lock-in amplifier-based setup utilizing the change in phase at this frequency shows a 100 times higher immunity to fluctuations in the optical path compared to the intensity-based approach. A noise floor of and a shot-noise-limited sensitivity of were determined.
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of and microscale spatial resolution while achieving a fiber sensor head cross section of less than .
In all-optical magnetic field sensing using nitrogen-vacancy-center-rich diamonds, an ambiguity in the range of 0–8 mT can be observed. We propose a way to resolve this ambiguity using the magnetic-field-dependent fluorescence lifetime. We therefore recorded the frequency response of the fluorescence upon modulation of the excitation intensity in a frequency range of 1–. The magnetic-field-dependent decay dynamics led to different response characteristics for magnetic fields below and above , allowing us to resolve the ambiguity. We used a physics-based model function to extract fit parameters, which we used for regression, and compared it to an alternative approach purely based on an artificial neural network.
Long coherence times at room temperature make the NV center a promising candidate for quantum sensors and quantum computers. The necessary coherent control of the electron spin triplet in the ground state requires microwave pulses in the nanosecond range, obtained from the Rabi oscillation of the mS spin states of the magnetic resonances of the NV centers. Laboratory equipment has a high temporal resolution for these measurements but is expensive and, therefore, uninteresting for fields such as education. In this work, we present measurement electronics for NV centers that are optimized for microcontrollers. It is shown that the Rabi frequency is linear to the output of the digital-to-analog converter (DAC) and is used to adapt the time length of the electron spin flip, to the limited pulse width resolution of the microcontroller. This was achieved by breaking down the most relevant functions of conventional laboratory devices and replacing them with commercially available integrated components. The result is a cost-effective handheld setup for coherent control applications of NV centers.
This paper presents the application of a compact and fully integrated LED quantum sensor based on the NV centers in diamond for current measurement in a busbar. The magnetic field measurements from the sensor are directly compared with measurements from a numerical simulation, eliminating the need for calibration. The sensor setup achieves an accuracy of 0.28% in the measurement range of 0–30 DC. The integration of advanced quantum sensing technology with practical current measurement demonstrates the potential of this sensor for applications in electrical and distribution networks.