Chengxin Su

Dr. Chengxin Su


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HLhua Liu
hua Liu
PJPinggang Jia
Pinggang Jia
CSChengxin Su
Chengxin Su
AZAihao Zhao
Aihao Zhao
JLJia Liu
Jia Liu
XJXiong Jijun
Xiong Jijun
In this paper, a fiber-optic Fabry–Perot (F–P) vibration sensor that can work at 800 °C is proposed. The F–P interferometer is composed of an upper surface of inertial mass placed parallel to the end face of the optical fiber. The sensor was prepared by ultraviolet-laser ablation and three-layer direct-bonding technology. Theoretically, the sensor has a sensitivity of 0.883 nm/g and a resonant frequency of 20.911 kHz. The experimental results show that the sensitivity of the sensor is 0.876 nm/g in the range of 2 g to 20 g at an operating frequency of 200 Hz at 20 °C. The nonlinearity was evaluated from 20 °C to 800 °C with a nonlinear error of 0.87%. In addition, the z-axis sensitivity of the sensor was 25 times higher than that of the x-axis and y-axis. The vibration sensor will have wide high-temperature engineering-application prospects.

1 May 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
CSChengxin Su
Chengxin Su
PJPinggang Jia
Pinggang Jia
AZAihao Zhao
Aihao Zhao
JTJiacheng Tu
Jiacheng Tu
JLJia Liu
Jia Liu
XJXiong Jijun
Xiong Jijun
A high-temperature-resistance single-crystal magnesium oxide (MgO) extrinsic Fabry–Perot (FP) interferometer (EFPI) fiber-optic vibration sensor is proposed and experimentally demonstrated at 1000 °C. Due to the excellent thermal properties (melting point > 2800 °C) and optical properties (transmittance ≥ 90%), MgO is chosen as the ideal material to be placed in the high-temperature testing area. The combination of wet chemical etching and direct bonding is used to construct an all-MgO sensor head, which is favorable to reduce the temperature gradient inside the sensor structure and avoid sensor failure. A temperature decoupling method is proposed to eliminate the cross-sensitivity between temperature and vibration, improving the accuracy of vibration detection. The experimental results show that the sensor is stable at 20–1000 °C and 2–20 g, with a sensitivity of 0.0073 rad (20 °C). The maximum nonlinearity error of the vibration sensor measurement after temperature decoupling is 1.17%. The sensor with a high temperature resistance and outstanding dynamic performance has the potential for applications in testing aero-engines and gas turbine engines.