Alex Huang

Prof. Alex Huang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2021 in Ophthalmology Science
Verified
Journal Article
Open access
JLJong Yeon Lee
Jong Yeon Lee
GHGad Heilweil
Gad Heilweil
PLPhuc Le
Phuc Le
SSSindhu Saraswathy
Sindhu Saraswathy
YHYoung-Kwon Hong
Young-Kwon Hong
AHAlex Huang
Alex Huang
To uncover the mechanism of subconjunctival outflow in humans. Cross-sectional study. Fifteen patients receiving subconjunctival anesthesia before intravitreal injection for routine clinical care. Anterior segment (AS) OCT was performed in patients with various instances of conjunctival edema or subconjunctival fluid. Other patients received a subconjunctival mixture of 0.005% indocyanine green and 2% lidocaine. After subconjunctival injection of the tracer and anesthetic mixture, blebs and associated outflow pathways were imaged angiographically and the time for appearance was recorded. The pattern and structure of outflow pathways were studied using AS OCT. Angiographic and AS OCT results were compared with trabecular and conventional outflow imaging, which demonstrates veins. Ocular surface lymphangiography and AS OCT images. Anterior segment OCT of the conjunctiva in a normal eye demonstrated thin nonedematous conjunctiva with absent intraconjunctival lumens or subconjunctival fluid. Patients with a history of trabeculectomy, subconjunctival drug injection, or chemosis demonstrated thickened conjunctiva and intraconjunctival luminal pathways that contained valve-like structures. Tracer-based studies in patients demonstrated blebs with irregular subconjunctival bleb-related outflow patterns that arose in a time-dependent fashion. These angiographic pathways were luminal on OCT, sausage shaped, and contained intraluminal valve-like structures. This was in contrast to trabecular and conventional outflow imaging, where pathways were classically Y-shaped, of even caliber, and lacked valve-like structures. Outflow pathways were seen in patients with conjunctival edema and after subconjunctival tracer injection. These pathways were lymphatic based on pattern and structural study. Better understanding of bleb-related lymphatic outflow may lead to improved bleb-requiring glaucoma surgeries and subconjunctival drug delivery.

7 April 2025 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
ASAlexander A. Svoronos
Alexander A. Svoronos
COCambria S. O’gRady
Cambria S. O’gRady
EWEvan Walker
Evan Walker
NANatalie A. Afshari
Natalie A. Afshari
BMBrandon R. Macias
Brandon R. Macias
AHAlex Huang
Alex Huang

15 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MCMichael Chaglasian
Michael Chaglasian
HHHuiyuan Hou
Huiyuan Hou
MTMayra Tafreshi
Mayra Tafreshi
MDMary Durbin
Mary Durbin
ETEce Turhal
Ece Turhal
AHAlex Huang
Alex Huang
Background/Objectives: This study aimed to evaluate the clinical interchangeability of intraocular pressure (IOP) measurements between a non-contact tonometer (NCT), the TRK-3 OMNIA, and Goldmann applanation tonometry (GAT) and to assess the repeatability of TRK-3 measurements. Methods: This prospective, multicenter study included 120 subjects stratified into three IOP groups based on GAT measurements: low IOP (7–16 mmHg), intermediate IOP (>16 to <23 mmHg), and high IOP (≥23 mmHg). The study eye was randomly selected from each subject. IOP was measured using both TRK-3 OMNIA and GAT following a standardized protocol. Agreement between the two methods was evaluated using Bland–Altman analysis, 95% limits of agreement (LoA), and equivalence testing via the two one-sided test (TOST) approach with a predefined ±5 mmHg margin. Linear regression analysis was performed to characterize the relationship between TRK-3 and GAT measurements. The repeatability of TRK-3 measurements was assessed using the intraclass correlation coefficient (ICC), repeatability limit, and coefficient of variation (CV). Results: Across all subjects, the mean difference between TRK-3 OMNIA and GAT IOP measurements was −0.2 mmHg. TRK-3 OMNIA overestimated IOP in the low IOP group (mean difference: 2.1 mmHg, LoA: −1.2 to 5.4 mmHg) and underestimated in the high IOP group (mean difference: −2.4 mmHg, LoA: −5.9 to 1.1 mmHg), while agreement was highest in the intermediate IOP group (−0.2 mmHg, LoA: −2.9 to 2.5 mmHg). Despite the systematic trend, equivalence testing confirmed statistical equivalence across all groups, with 90% confidence intervals (CI) of 1.7 to 2.5 mmHg (low IOP group), −0.6 to 0.2 mmHg (intermediate IOP group), and −2.9 to −2.0 mmHg (high IOP group). Linear regression analysis found a strong correlation (r = 0.92) between TRK-3 and GAT. The TRK-3 OMNIA demonstrated good repeatability, with an ICC of 0.94, a repeatability limit of 3.12 mmHg, and a CV of 5.65%. The repeatability limits were 2.22 mmHg, 2.60 mmHg, and 4.19 mmHg in the low, intermediate, and high IOP groups, respectively. Conclusions: TRK-3 OMNIA and GAT measurements showed strong agreement, statistical equivalence, and a high correlation, supporting their clinical interchangeability. TRK-3 also demonstrated high repeatability. These findings indicate that this automated non-contact tonometer provides reliable and repeatable IOP measurements, supporting its integration into routine clinical workflows.

20 June 2025 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
YHYe He
Ye He
RKRustum Karanjia
Rustum Karanjia
XZXiaowei Zhang
Xiaowei Zhang
DWDaniel Wanderer
Daniel Wanderer
EWEvan Walker
Evan Walker
AHAlex Huang
Alex Huang

22 October 2024
Verified
Book Chapter
Closed access
PDF file
CSClemens A. Strohmaier
Clemens A. Strohmaier
FMFiona McDonnell
Fiona McDonnell
AHAlex Huang
Alex Huang

25 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
HSHan Shen
Han Shen
JAJiahe Ai
Jiahe Ai
ZCZhaoyi Chen
Zhaoyi Chen
AHAlex Huang
Alex Huang
VMVinit B. Mahajan
Vinit B. Mahajan
YLYuancheng Ryan Lu
Yuancheng Ryan Lu
Oxidative stress accumulates early in the central nervous system (CNS) and is one major driver of age-related neurodegeneration. Here we compare major oxidative-stress models, highlighting their distinct mechanisms and disease relevance. We summarize therapeutic strategies ranging from radical scavengers and endogenous antioxidant enhancers to mitochondrial-targeted agents and rejuvenation approaches that restore intrinsic cytoprotective programs. We further discuss emerging oxidative-stress profiling strategies to define individual redox vulnerabilities. Together, mechanistically informed modeling, multidimensional profiling, and targeted restoration of oxidative resilience may enable more precise interventions for age-related CNS degeneration.