Photodetectors are critical components in a wide range of applications, from imaging and sensing to communications and environmental monitoring. Recent advancements in material science have led to the development of emerging photodetecting materials, such as perovskites, polymers, novel two-dimensional materials, and quantum dots, which offer unique optoelectronic properties and high tunability. This review presents a comprehensive overview of the synthesis methodologies for these cutting-edge materials, highlighting their potential to enhance photodetection performance. Additionally, we explore the design and fabrication of photodetectors with novel structures and physics, emphasizing devices that achieve high figure-of-merit parameters, such as enhanced sensitivity, fast response times, and broad spectral detection. Finally, we discuss the demonstration of new applications enabled by these advanced photodetectors, including flexible and wearable devices, next-generation imaging systems, and environmental sensing technologies. Through this review, we aim to provide insights into the current trends and future directions in the field of photodetection, guiding further research and development in this rapidly evolving area.
5 April 2021 in IEEE Transactions on Electron Devices
In this article, a 1-THz traveling-wave tube (TWT) based on flat-roofed sine waveguide (SWG) slow wave structure (SWS) has been studied theoretically and experimentally, and parts of the component have been fabricated. First, the flat-roofed SWG SWS has been optimized for working at 1 THz, the normalized phase velocity is around 0.287, and the interaction impedance is over 3.5 Ω in the frequency range of 1.02-1.04 THz. Meanwhile, the performance of the designed TWT has been simulated, whose saturated output power is 720 mW and the corresponding gain is 28.57 dB. What is more, to decrease the transmission loss of the high-frequency structure, the input and output structures have been designed and a transition structure that transforms the waveguide to standard rectangular waveguide has been proposed. The simulation results show that the reflection coefficient of the novel proposed transmission system is less than -20 dB, and the insertion losses of the transition structure with the input and output waveguides are 2.45 and 1.68 dB, respectively. Finally, the designed SWS has been fabricated by deep reactive-ion etching (DRIE) and tested; S 11 is generally less than -10 dB in the frequency range of 1020-1040 GHz.
In this work, a mini monitoring system integrated with a microfabricated metal oxide array sensor and a micro packed gas chromatographic (GC) column was developed for monitoring environmental gases. The microfabricated packed GC column with a 1.6 m length was used to separate the environmental gas, and the metal oxide semiconductor (MOS) array sensor, fabricated with nano-sized SnO-SnO2 sensitive materials, was able to effectively detect each component separated by GC column. The results demonstrate that the monitoring system can detect environmental gas with high precision.
Nano-engineered sensor systems represent a paradigm shift in disease diagnostics, offering unprecedented capabilities for precision medicine. This review methodically evaluates these advanced platforms, consolidating recent advancements across four critical clinical domains: diabetes monitoring, cancer detection, infectious disease diagnostics and cardiac/genetic health. We demonstrate how the unique properties of nanomaterials, such as graphene, quantum dots and plasmonic nanoparticles, are being harnessed to achieve remarkable gains in analytical sensitivity, selectivity and real-time monitoring. Specific breakthroughs include graphene-based sensors attaining clinically significant limits for continuous glucose monitoring, quantum dot bioconjugates enabling ultrasensitive imaging of cancer biomarkers and surface-enhanced Raman spectroscopy (SERS) probes facilitating early tumor identification. Furthermore, nanosensors exhibit exceptional precision in detecting viral antigens and genetic mutations, underscoring their robust translational potential. Collectively, these developments signal a clear trajectory toward integrated, intelligent healthcare ecosystems. However, for these promising technologies to transition into accessible and cost-effective diagnostic solutions, persistent challenges in scalability, manufacturing reproducibility and long-term biocompatibility must be addressed through continued interdisciplinary innovation.
Atmospheric particulate matter (PM) air-microfluidic grading chip is the premise for realizing high-precision PM online monitoring. It can be used as an indispensable basis for identifying pollution sources and controlling inhalable harmful substances. In this paper, based on aerodynamic theory and COMSOL numerical analysis, a two-stage PM air-microfluidic grading chip with cut-off diameters of 10 μm and 2.5 μm was designed. The effects of chip inlet width (W), main flow width (L), second channel width (S), and split ratio (Q1/Q) on PM classification efficiency were analyzed, and optimized design parameters were achieved. The collection efficiency curves were plotted according to PM separation effects of the chip on various particle sizes (0.5–15 μm). The results indicate that the chip has good separation effect, which provides an efficient structural model for the PM micro-fluidization chip design.
A miniature Fourier transform spectrometer is proposed using a thin-film lithium niobate electro-optical modulator instead of the conventional modulator made by titanium diffusion in lithium niobate. The modulator was fabricated by a contact lithography process, and its voltage-length and optical waveguide loss were 2.26 V·cm and 1.01 dB/cm, respectively. Based on the wavelength dispersion of the half-wave voltage of the fabricated modulator, the emission spectrum of the input signal was retrieved by Fourier transform processing of the interferogram, and the analysis of the experimental data of monochromatic light shows that the proposed miniaturized FTS can effectively identify the input signal wavelength.