Lara Berger

Dr. Lara Berger

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ASAnna Seidel
Anna Seidel
CSChristian Schmitt
Christian Schmitt
RMRagai Matta
Ragai Matta
Mayte BuchbenderMayte Buchbender
Mayte Buchbender
MWManfred Wichmann
Manfred Wichmann
LBLara Berger
Lara Berger
Background: In mucogingival and implant surgery, an autologous soft tissue graft from the palate is the gold standard for reconstructing missing keratinised soft tissue and volume. Previously, presurgical measurements of the graft harvesting site were described with two-dimensional (2D) linear measurements. The present observational clinical study aimed to evaluate a three-dimensional (3D) measurement method for determining the present palatal soft tissue volume for each patient individually. Methods: Pre-existing cone beam computed tomography (CBCT) scans of 20 patients were converted into 3D Standard Tessellation Language models of the bone surface. Intraoral impressions of the maxilla were taken and digitised to visualise the gingival surface. The resulting virtual models of bone (reference value) and gingival (actual value) surfaces were merged, with tooth surfaces used for registration. The region between the central incisors and the hard palate was subdivided into 5 regions of interest (ROIs). The distance between palatal bone and gingival surface was analysed both volumetrically and linearly, and the results were statistically evaluated for the ROIs. Results: The average gingival surface area on the palate was 19.1 cm2, and the mean volume was 58.2 cm3 (± 16.89). Among the ROIs, the mean linear value was highest in the most distal region, from the second molar to the hard palate (4.0 ± 1.09 mm) and lowest in the canine region (1.9 ± 0.63 mm). For mean distance, significant differences were found for the anterior palate and the most posterior palate in comparison with all other ROIs (p < 0.01). The volume measurements also declined significantly and steadily between the posterior (1.9 ± 1.0 cm3) and anterior palates (0.4 ± 0.2 cm3). Conclusions: By merging digital data, palatal soft tissue could be quantified virtually. The results were reliable and comparable to previous findings with linear measurement methods. This 3D soft tissue volume analysis method fully exploited the diagnostic potential of data that are frequently collected for presurgical planning in oral surgery (i.e., CBCT + surface scans). This evaluation method might be useful for volumetric and linear measurements in other applications in anatomy and for determining palatal soft tissue dimensions in the planning stage before surgical interventions. Trial registration: This observational clinical trial was retrospectively registered in the German Clinical Trials Register, reference number: DRKS00023918.

6 May 2024 in Materials
Verified
Journal Article
Open access
PDF file
RMRagai Matta
Ragai Matta
LBLara Berger
Lara Berger
MLMoritz Loehlein
Moritz Loehlein
LLLinus Leven
Linus Leven
JTJuergen Taxis
Juergen Taxis
CMConstantin Motel
Constantin Motel
Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.

3 April 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
JKJudith Kropfeld
Judith Kropfeld
LBLara Berger
Lara Berger
WAWerner Adler
Werner Adler
KSKatja Leonie Schulz
Katja Leonie Schulz
CMConstantin Motel
Constantin Motel
RMRagai Matta
Ragai Matta
The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed—automatically and manually—with the scanbody geometries stored within the software’s shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

1 May 2024 in Materials
Verified
Journal Article
Open access
PDF file
LBLara Berger
Lara Berger
RMRagai Matta
Ragai Matta
CWChristian Markus Weiß
Christian Markus Weiß
WAWerner Adler
Werner Adler
MWManfred Wichmann
Manfred Wichmann
JZJosé Ignacio Zorzin
José Ignacio Zorzin
The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass–ionomer (B), self-adhesive resin (C), or resin-modified glass–ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal–Wallis and Mann–Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.

23 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
ASAlexander Strunz
Alexander Strunz
LBLara Berger
Lara Berger
ASAnna Seidel
Anna Seidel
JRJohannes Ries
Johannes Ries
WAWerner Adler
Werner Adler
RMRagai Matta
Ragai Matta
This study examines the impact of different 3D printing technologies on the accuracy of implant positions in printed dental models, a crucial factor in implant-supported prosthetics. A standardized titanium model with three bone-level implants was scanned using an industrial scanner to create a virtual reference model. Ten intraoral scans of the same model were performed, and the generated STL files were used to design physical models printed with three different 3D printers: two utilizing digital light processing (DLP) technology and one employing stereolithography (SLA) (n = 30). The printed models were then rescanned, and deviations from the reference STL file were analyzed. Results showed that the SLA printer exhibited the highest deviations (0.26 ± 0.17 mm), whereas the DLP printers demonstrated greater accuracy, with one DLP system (0.07 ± 0.02 mm) performing slightly better than the other (0.12 ± 0.13 mm). The SLA printer exhibited the most significant errors in the vestibulo-oral and occlusal-apical directions. The findings suggest that DLP printers offer superior precision for implant-supported restorations in digital workflows. Clinically, the choice of 3D printing technology significantly impacts model accuracy, emphasizing the importance of selecting the appropriate printer based on the required precision.

9 May 2025 in Materials
Verified
Journal Article
Open access
PDF file
LBLara Berger
Lara Berger
FFFelix Förtsch
Felix Förtsch
RKRalf Kretschmer
Ralf Kretschmer
OSOleksandr Sednyev
Oleksandr Sednyev
JZJosé Ignacio Zorzin
José Ignacio Zorzin
RMRagai Matta
Ragai Matta
Utilizing dental CAD/CAM systems, chairside treatments allow patients to be treated within one day without the need for an intermediate dental laboratory. With this procedure, it is also essential to ensure a sufficient marginal fit of the restoration. Therefore, this study investigates the influence of the milling strategy on the marginal fit of CAD/CAM-fabricated lithium disilicate crowns. For this purpose, 10 crowns were fabricated from each of the materials IPS e.max CAD and Celtra Duo using the fastest and finest available milling strategy. The accuracy of the marginal fit of the 40 crowns was examined using the industrial scanner ATOS Triple Scan and the associated software using the triple scan protocol. In a comparison of the milling processes, the restorations fabricated using the finest process always exhibited a better marginal fit, with mean deviations of 87 μm and 146 μm for IPS e.max CAD and 111 μm and 118 μm for Celtra Duo. The difference was only statistically significant for the crowns made of IPS e.max CAD (p = 0.008). All mean deviations determined were below the clinically acceptable marginal gap values (150 μm). Both materials can be used for chairside-fabricated crowns; however, choosing the faster milling strategy leads to higher marginal discrepancies.