MARINE BORDET

Dr. MARINE BORDET

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
MBMARINE BORDET
MARINE BORDET
PTPhilippe Tresson
Philippe Tresson
UHUgo Huvelle
Ugo Huvelle
ALAnne Long
Anne Long
GPGuillaume Passot
Guillaume Passot
NSNellie Della Schiava
Nellie Della Schiava

2 May 2024 in Materials
Verified
Journal Article
Open access
PDF file
STSimon Toinet
Simon Toinet
MBMohamed Benwadih
Mohamed Benwadih
HSHelga SZAMBOLICS
Helga SZAMBOLICS
CRChristine Revenant
Christine Revenant
DADavid Alincant
David Alincant
PCPierre-Jean COTTINET
Pierre-Jean COTTINET
To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.

16 January 2025 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
SBSara Boccalini
Sara Boccalini
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
KEKlaus Erhard
Klaus Erhard
MBMARINE BORDET
MARINE BORDET
YYYoad Yagil
Yoad Yagil
PDPhilippe Douek
Philippe Douek

5 September 2022 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
MBMARINE BORDET
MARINE BORDET
AOAlexandre Oliny
Alexandre Oliny
TMTiphaine Miasumu
Tiphaine Miasumu
PTPhilippe Tresson
Philippe Tresson
PLPatrick Lermusiaux
Patrick Lermusiaux
AMAntoine Millon
Antoine Millon

5 November 2025 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
AHAurélien Hostalrich
Aurélien Hostalrich
TMThomas Mesnard
Thomas Mesnard
JDJean-Michel Davaine
Jean-Michel Davaine
SMSergei Malikov
Sergei Malikov
LSLucie Salomon
Lucie Salomon
XCXavier Chaufour
Xavier Chaufour
This study aimed to report the midterm results of fenestrated endovascular aortic repair (FEVAR) and open surgical repair (OSR) following failed endovascular aneurysm repair with type Ia endoleak. An observational multicentre study was conducted in 13 French university centres with 88 FEVARs and 120 OSRs in 208 patients. After propensity score matching, 136 matched patients were analysed. Thirty day mortality was higher in the OSR group than the FEVAR group (7% vs. 3%; p = .24). Thirty day complications were statistically significantly higher in the OSR group for kidney injury (p = .001) and respiratory failure (p = .029). The rate of paraplegia was statistically significantly higher after FEVAR (6% vs. 0%, p = .042). Type Ia endoleak treatment was achieved in 67/68 FEVAR patients and in all OSR patients. Survival at 2 years was comparable in the two groups with 88 ± 4% for OSR vs. 94 ± 3% for FEVAR (p = .83). Re-intervention free survival at 2 years was higher in the OSR group vs. the FEVAR group (86 ± 4% vs. 73 ± 6%; log rank, p = .037). Irrespective of the technique used, freedom from late re-intervention at 2 years was statistically significantly higher in patients without persistent type II endoleak (T2EL) (84 ± 6%) compared with those with persistent T2EL (43 ± 9%) (log rank, p < .001). Re-interventions occurred in 36 patients (26.5%), with 30/68 (44%) in the FEVAR group and 6/68 (9%) in the OSR group (p < .001). Following FEVAR, thrombosis of the aneurysmal sac was obtained in 16/68 patients (29%). Cox proportional hazards showed that OSR was associated with a lower probability of late re-interventions compared with FEVAR (hazard ratio [HR] 0.27, 95% confidence interval [CI] 0.11 - 0.69; p = .006) and that persistent T2EL showed a higher probability of re-intervention (HR 3.09, 95% CI 1.49 - 6.41; p = .002). In this multicentre study with propensity matching, mortality and complications at 30 days were higher in the OSR group, and FEVAR was associated with more late re-interventions, particularly in patients with concomitant persistent T2EL.

1 December 2021 in Mayo Clinic Proceedings
Verified
Journal Article
Closed access
MBMARINE BORDET
MARINE BORDET
ALAnne Long
Anne Long
PTPhilippe Tresson
Philippe Tresson