Klaus Erhard

Klaus Erhard

Auto-generated profile, based on publicly available information

Klaus Erhard

Philips GmbH Innovative Technologies, 22335 Hamburg, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Radiology
Verified
Journal Article
Closed access
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
SBSara Boccalini
Sara Boccalini
HLHugo Lacombe
Hugo Lacombe
ADAdja Diaw
Adja Diaw
MVMohammad Varasteh
Mohammad Varasteh
PDPhilippe C. Douek
Philippe C. Douek
Photon-counting CT enables improved image quality and diagnostic confidence for coronary CT angiography examinations at comparable dose, in comparison to an energy-integrating detector dual-layer CT. Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiogr...

16 January 2025 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
SBSara Boccalini
Sara Boccalini
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
KEKlaus Erhard
Klaus Erhard
MBMARINE BORDET
MARINE BORDET
YYYoad Yagil
Yoad Yagil
PDPhilippe Douek
Philippe Douek

25 June 2026 in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
ARAntoine Robert
Antoine Robert
SPSofia Poletto
Sofia Poletto
KEKlaus Erhard
Klaus Erhard
MAMaria Nicole Antonuccio
Maria Nicole Antonuccio
CHChristian A. Hernandez
Christian A. Hernandez
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
The purpose of this study was to assess the feasibility of color K-edge imaging enabled by spectral photon-counting CT (SPCCT) for simultaneous ventilation-perfusion evaluation using xenon and a gadolinium-based agent within healthy rabbit lungs. In this animal study, a clinical SPCCT prototype was used to perform lung imaging in five New Zealand white rabbits. A phantom study was performed to assess gadolinium quantification accuracy and cross-contamination. Animals underwent controlled mechanical ventilation with xenon gas wash-in and received an intravenous injection of a gadolinium-based ultrasmall rigid platform (USRP) (dose, 2.3 mL·kg-1; injection rate, 3 mL·s-1; concentration, 0.29 mmol Gd.mL-1). Material decomposition yielded specific xenon and gadolinium K-edge images. Xenon maps were validated against dynamic specific ventilation maps using Pearson correlation test and linear regression analysis. Regional lung distribution was analyzed using Kruskal-Wallis test. Five rabbits (mean weight, 2.9 ± 0.06 [standard deviation] kg) were evaluated. In phantoms, measured gadolinium concentrations showed a perfect linear correlation with prepared concentrations (R2 = 1). In vivo, normalized steady-state xenon maps demonstrated a strong correlation with specific ventilation maps, with a pooled Pearson correlation coefficient of 0.88 and a pooled R2 of 0.78. Simultaneous imaging revealed a homogeneous xenon distribution with a median value across rabbits of 60.2% (first quartile [Q1], 59.3%; third quartile [Q3], 67.9%), with no significant regional differences. The median gadolinium perfusion across rabbits was 6.1% (Q1, 3.0%; Q3, 7.1%), with a significant dorsal-ventral gradient (P < 0.05) where the median value increased from 0.2% (Q1, -0.2%; Q3, 1.3%) in ventral regions to 6.9% (Q1, 3.8%; Q3, 10.6%) in dorsal regions. Color K-edge xenon/gadolinium-enhanced lung imaging using SPCCT is feasible in healthy animals, enabling the simultaneous specific and quantitative imaging of lung gas and blood volume.

12 October 2026 in Physica Medica
Verified
Journal Article
Open access
AGAgnieszka J. Gutwinska
Agnieszka J. Gutwinska
DRDerick Rosario
Derick Rosario
ARAntoine Robert
Antoine Robert
ETEloise Thomas
Eloise Thomas
APAmanda Pang
Amanda Pang
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed