21 March 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ZLZhuofu Li
Zhuofu Li
CWChengxia Wang
Chengxia Wang
XSXiongkang Song
Xiongkang Song
SLShanshan Liu
Shanshan Liu
YZYonghong Zhang
Yonghong Zhang
WLWeishi Li
Weishi Li
Background: The main function of robots in spine surgery is to assist with pedicle screw placement. Laminectomy, which is as important as pedicle screw placement, lacks a mature robot-assisted system. The aims of this study were to introduce the first autonomous laminectomy robot, to explore the feasibility of autonomous robotic laminectomy, and to validate its accuracy using a cadaveric model. Methods: Forty vertebrae from 4 cadavers were included in the study; 7 thoracic and 3 lumbar vertebrae were randomly selected in each cadaver. The surgeon was able to plan the laminectomy path based on computed tomographic (CT) data before the surgical procedure. The robot performed the laminectomy autonomously, and a postoperative CT scan was made. The deviation of each cutting plane from the plan was quantitatively analyzed, and the accuracy and safety were qualitatively evaluated. The time required for the laminectomy was also recorded. Results: Cuts were performed in 80 laminectomy planes (56 for thoracic vertebrae and 24 for lumbar vertebrae). The mean time for 1-sided laminectomy was 333.59 ± 116.49 seconds, which was shorter for thoracic vertebrae (284.41 ± 66.04 seconds) than lumbar vertebrae (448.33 ± 128.65 seconds) (p < 0.001). The mean time for single-level total laminectomy was 814.05 ± 302.23 seconds, which was also shorter for thoracic vertebrae (690.46 ± 165.74 seconds) than lumbar vertebrae (1,102.42 ± 356.13 seconds) (p = 0.002). The mean deviation of the cutting plane from the plan was 0.67 ± 0.30 mm for the most superior cutting point and 0.73 ± 0.31 mm for the most inferior point. There were no significant differences in the deviation between thoracic vertebrae (0.66 ± 0.26 mm) and lumbar vertebrae (0.67 ± 0.38 mm) at the superior cutting point (p = 0.908) and between thoracic vertebrae (0.72 ± 0.30 mm) and lumbar vertebrae (0.73 ± 0.33 mm) at the inferior cutting point (p = 0.923). In the qualitative analysis of the accuracy of the 80 laminectomy planes, 66 (83%) were classified as grade A, 14 (18%) were grade B, and none was grade C. In the safety analysis, 65 planes (81%) were considered safe and the safety of the other 15 planes (19%) was considered uncertain. Conclusions: The results confirmed the accuracy of this robotic system, supporting its use for laminectomy of thoracolumbar vertebrae. Level of Evidence: Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.

1 February 2023 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
XZXiaohui Zhang
Xiaohui Zhang
XJXuquan Ji
Xuquan Ji
JWJunchen Wang
Junchen Wang
YFYubo Fan
Yubo Fan
CTChunjing Tao
Chunjing Tao

1 January 2018 in Journal of Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
XJXuquan Ji
Xuquan Ji

2 September 2024 in IEEE Access
Verified
Journal Article
Open access
ZLZhuoyuan Li
Zhuoyuan Li
XJXuquan Ji
Xuquan Ji
CWchuantao wang
chuantao wang
WLWenyong Liu
Wenyong Liu
FZFeiyu Zhu
Feiyu Zhu
JZJiliang Zhai
Jiliang Zhai
Medical image registration is a crucial process in medical image analysis. However, traditional 2D and 3D medical image registration methods often struggle to accommodate the complex variations and conditions present in medical images. To address these challenges, this study introduces a novel 2D/3D image registration framework, termed 2D/3D-MGR, which leverages digitally reconstructed radiographs (DRR) to establish consistency between X-ray and computed tomography (CT) images. This research introduces the DCT-Net model for style transfer between DRR and X-ray images, and the CR-Net model for precise registration of intraoperative X-ray images with preoperative CT images. To validate the effectiveness of the proposed models, orthopedic X-ray and CT images were collected from Peking Union Medical College Hospital to create the XC dataset. Empirical results demonstrate that the DCT-Net model achieves a transformation quality level endorsed by medical experts, and the realistic style transfer is significant for subsequent image registration and surgical navigation. Additionally, the CR-Net model outperforms other state-of-the-art models in image registration accuracy, as evidenced by outstanding performance metrics on the XC spine dataset: a Pointwise Location Consistency (PLC) of 99.997% and a Root Mean Square Error (RMSE) of 0.1707. This novel image registration method significantly enhances the accuracy and efficiency of medical image processing, providing a valuable reference for future research in medical image registration.

21 April 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
XJXuquan Ji
Xuquan Ji
YZYonghong Zhang
Yonghong Zhang
HSHuaqing Shang
Huaqing Shang
LHLei Hu
Lei Hu
XQXiaozhi Qi
Xiaozhi Qi
WLWenyong Liu
Wenyong Liu
The calibration of ultrasound probes is essential for three-dimensional ultrasound reconstruction and navigation. However, the existing calibration methods are often cumbersome and inadequate in accuracy. In this paper, a hybrid mathematical model, Dimensionality Reduction and Homography Transformation (DRHT), is proposed. The model characterizes the relationship between the image plane of ultrasound and projected calibration lines and homography transformation. The homography transformation, which can be estimated using the singular value decomposition method, reduces the dimensionality of the calibration data and could significantly accelerate the computation of image points in ultrasonic three-dimensional reconstruction. Experiments comparing the DRHT method with the PLUS library demonstrated that DRHT outperformed the PLUS algorithm in terms of accuracy (0.89 mm vs. 0.92 mm) and efficiency (268 ms vs. 761 ms). Furthermore, high-precision calibration can be achieved with only four images, which greatly simplifies the calibration process and enhances the feasibility of the clinical application of this model.

22 August 2025 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
XJXuquan Ji
Xuquan Ji
YZYonghong Zhang
Yonghong Zhang
YZYuanyuan Zhu
Yuanyuan Zhu
BYBiao Yang
Biao Yang
LHLei Hu
Lei Hu
WLWenyong Liu
Wenyong Liu