Yonghong Zhang

Prof. Dr. Yonghong Zhang

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ZLZhuofu Li
Zhuofu Li
CWChengxia Wang
Chengxia Wang
XSXiongkang Song
Xiongkang Song
SLShanshan Liu
Shanshan Liu
YZYonghong Zhang
Yonghong Zhang
WLWeishi Li
Weishi Li
Background: The main function of robots in spine surgery is to assist with pedicle screw placement. Laminectomy, which is as important as pedicle screw placement, lacks a mature robot-assisted system. The aims of this study were to introduce the first autonomous laminectomy robot, to explore the feasibility of autonomous robotic laminectomy, and to validate its accuracy using a cadaveric model. Methods: Forty vertebrae from 4 cadavers were included in the study; 7 thoracic and 3 lumbar vertebrae were randomly selected in each cadaver. The surgeon was able to plan the laminectomy path based on computed tomographic (CT) data before the surgical procedure. The robot performed the laminectomy autonomously, and a postoperative CT scan was made. The deviation of each cutting plane from the plan was quantitatively analyzed, and the accuracy and safety were qualitatively evaluated. The time required for the laminectomy was also recorded. Results: Cuts were performed in 80 laminectomy planes (56 for thoracic vertebrae and 24 for lumbar vertebrae). The mean time for 1-sided laminectomy was 333.59 ± 116.49 seconds, which was shorter for thoracic vertebrae (284.41 ± 66.04 seconds) than lumbar vertebrae (448.33 ± 128.65 seconds) (p < 0.001). The mean time for single-level total laminectomy was 814.05 ± 302.23 seconds, which was also shorter for thoracic vertebrae (690.46 ± 165.74 seconds) than lumbar vertebrae (1,102.42 ± 356.13 seconds) (p = 0.002). The mean deviation of the cutting plane from the plan was 0.67 ± 0.30 mm for the most superior cutting point and 0.73 ± 0.31 mm for the most inferior point. There were no significant differences in the deviation between thoracic vertebrae (0.66 ± 0.26 mm) and lumbar vertebrae (0.67 ± 0.38 mm) at the superior cutting point (p = 0.908) and between thoracic vertebrae (0.72 ± 0.30 mm) and lumbar vertebrae (0.73 ± 0.33 mm) at the inferior cutting point (p = 0.923). In the qualitative analysis of the accuracy of the 80 laminectomy planes, 66 (83%) were classified as grade A, 14 (18%) were grade B, and none was grade C. In the safety analysis, 65 planes (81%) were considered safe and the safety of the other 15 planes (19%) was considered uncertain. Conclusions: The results confirmed the accuracy of this robotic system, supporting its use for laminectomy of thoracolumbar vertebrae. Level of Evidence: Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.

6 September 2022 in CAAI Transactions on Intelligence Technology
Verified
Journal Article
Open access
YZYonghong Zhang
Yonghong Zhang
NHNing Hu
Ning Hu
ZLZhuofu Li
Zhuofu Li
XJXuquan Ji
Xuquan Ji
SLShanshan Liu
Shanshan Liu
WLWeishi Li
Weishi Li
To eliminate unnecessary background information, such as soft tissues in original CT images and the adverse impact of the similarity of adjacent spines on lumbar image segmentation and surgical path planning, a two‐stage approach for localising lumbar segments is proposed. First, based on the multi‐scale feature fusion technology, a non‐linear regression method is used to achieve accurate localisation of the overall spatial region of the lumbar spine, effectively eliminating useless background information, such as soft tissues. In the second stage, we directly realised the precise positioning of each segment in the lumbar spine space region based on the non‐linear regression method, thus effectively eliminating the interference caused by the adjacent spine. The 3D Intersection over Union (3D_IOU) is used as the main evaluation indicator for the positioning accuracy. On an open dataset, 3D_IOU values of 0.8339 ± 0.0990 and 0.8559 ± 0.0332 in the first and second stages, respectively is achieved. In addition, the average time required for the proposed method in the two stages is 0.3274 and 0.2105 s respectively. Therefore, the proposed method performs very well in terms of both precision and speed and can effectively improve the accuracy of lumbar image segmentation and the effect of surgical path planning.

26 April 2024 in CAAI Transactions on Intelligence Technology
Verified
Journal Article
Open access
JZJian Zhang
Jian Zhang
YZYonghong Zhang
Yonghong Zhang
SLShanshan Liu
Shanshan Liu
XJXuquan Ji
Xuquan Ji
SLSizhuo Liu
Sizhuo Liu
TWTianmiao Wang
Tianmiao Wang
Laminectomy is one of the most common posterior spinal operations. Since the lamina is adjacent to important tissues such as nerves, once damaged, it can cause serious complications and even lead to paralysis. In order to prevent the above injuries and complications, ultrasonic bone scalpel and surgical robots have been introduced into spinal laminectomy, and many scholars have studied the recognition method of the bone tissue status. Currently, almost all methods to achieve recognition of bone tissue are based on sensor signals collected by high‐precision sensors installed at the end of surgical robots. However, the previous methods could not accurately identify the state of spinal bone tissue. Innovatively, the identification of bone tissue status was regarded as a time series classification task, and the classification algorithm LSTM‐FCN was used to process fusion signals composed of force and cutting depth signals, thus achieving an accurate classification of the lamina bone tissue status. In addition, it was verified that the accuracy of the proposed method could reach 98.85% in identifying the state of porcine spinal laminectomy. And the maximum penetration distance can be controlled within 0.6 mm, which is safe and can be used in practice.

21 April 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
XJXuquan Ji
Xuquan Ji
YZYonghong Zhang
Yonghong Zhang
HSHuaqing Shang
Huaqing Shang
LHLei Hu
Lei Hu
XQXiaozhi Qi
Xiaozhi Qi
WLWenyong Liu
Wenyong Liu
The calibration of ultrasound probes is essential for three-dimensional ultrasound reconstruction and navigation. However, the existing calibration methods are often cumbersome and inadequate in accuracy. In this paper, a hybrid mathematical model, Dimensionality Reduction and Homography Transformation (DRHT), is proposed. The model characterizes the relationship between the image plane of ultrasound and projected calibration lines and homography transformation. The homography transformation, which can be estimated using the singular value decomposition method, reduces the dimensionality of the calibration data and could significantly accelerate the computation of image points in ultrasonic three-dimensional reconstruction. Experiments comparing the DRHT method with the PLUS library demonstrated that DRHT outperformed the PLUS algorithm in terms of accuracy (0.89 mm vs. 0.92 mm) and efficiency (268 ms vs. 761 ms). Furthermore, high-precision calibration can be achieved with only four images, which greatly simplifies the calibration process and enhances the feasibility of the clinical application of this model.

30 December 2002
Verified
Conference Paper
Closed access
ZCZhe Chen
Zhe Chen
KCKang Chen
Kang Chen
YZYonghong Zhang
Yonghong Zhang
JHJ.C. Hung
J.C. Hung
Introduced in this paper is a land-based automatic vehicle location (AVL) expert system in the city and the suburbs environment of Beijing, China. Some issues about the data structure and graphic display are taken into account. A variety of expert knowledges and rules are stored in static or dynamic data bases for applications. A* algorithm is applied to determine the minimum cost route between the start and goal nodes. An example on route finding is given to show the effectiveness of A* algorithm. The route guidance functions are discussed in some detail. It is shown that the expert system of AVL developed in this paper is successful.

4 May 2026 in Pattern Recognition
Verified
Journal Article
Closed access
YZYonghong Zhang
Yonghong Zhang
BGBaoduo Geng
Baoduo Geng
YZYuanyuan Zhu
Yuanyuan Zhu
XJXuquan Ji
Xuquan Ji
LHLei Hu
Lei Hu
YXYumei Xue
Yumei Xue