The modular multilevel converter (MMC) is a promising candidate for the high-voltage and high-power applications. Fault localization is an important issue for the reliable operation of the MMC. The localization strategies of switch open-circuit failures for the MMCs in the inverter mode have been widely reported in the existing literature. This paper proposed a complete fault localization strategy for the MMC in the rectifier mode. In this paper, the differences of the fault characteristics between the inverter mode and rectifier mode are analyzed in detail. Based on that, the switch signal is used as the criterion for the fault localization. After the faulty submodule (SM) is identified, combining the switch signal and the capacitor voltage of the faulty SM can further locate the faulty switch. The proposed strategy can simplify the localization and identify three kinds of switch failures in SMs. In addition, the validity of the proposed strategy is verified by the simulation results.
14 May 2021 in IEEE Transactions on Power Delivery
The capacitor voltage balancing algorithm (VBA) is an important issue to maintain the regular operation of modular multilevel converter (MMC). However, it requires a higher switching frequency to obtain a better balancing performance. In this paper, the VBA based on the reassignment of switching times is proposed to improve the balancing performance of capacitor voltages with a low operating frequency. The mechanism of the reduced switching frequency voltage balancing algorithm (RSFVBA) is presented. Based on that, the relationship among switching times, switching frequency, and capacitor voltage deviation is deduced. And then, the voltage deviations in the positive and negative intervals of the arm current are analyzed in detail. The RSFVBA proposed in this paper adjusts the switching times of SMs in different intervals of arm current to reduce the voltage deviation. Moreover, the proposed RSFVBA can also provide a low operating frequency because the reassignment of switching times does not change the total switching times in a line cycle. The feasibility of the proposed strategy is verified by simulation results in the professional tool Matlab/Simulink.
30 November 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
The capacitors are one of the most important com- ponents in modular multilevel converter (MMC). Due to the large numbers of capacitors applied in MMC, the primary technical challenge about the capacitors is reliability. To identify the abnormal capacitors and improve the performance of MMCs, the capacitor condition monitoring strategy is proposed in this brief. In the monitoring algorithm, the relationship of the capacitances in an arm is deduced. The actual and nominal sums of switching signals for submodules (SM) are used to estimate the capacitances. Furthermore, a compensation for dead time is added to enhance the monitoring accuracy. The proposed condition monitoring algorithm not only simplifies the calculation of capacitances with high accuracy, but also has no adverse influence on the normal operation of MMCs. The feasibility of the proposed strategy is verified by the simulation results in MATLAB/Simulink.
20 May 2022 in IEEE Transactions on Power Delivery
The capacitor condition monitoring is an important issue for the reliable operation of modular multilevel converters (MMCs) in high-voltage applications. The numerous capacitors make the monitoring for the capacitor condition complex and computation-consuming. This paper proposes a hierarchic capacitor condition monitoring strategy to assure the reliability of high-voltage MMCs. In the strategy, the switching times of the switching signals are counted to detect the condition of the capacitor in each submodule (SM). Then, the subsequent capacitance calculation method is only conducted to the abnormal capacitors indicated by the above condition detection algorithm. Meanwhile, the variations of the measured and reference capacitor voltages are employed to calculate the capacitance in the proposed method. The condition detection algorithm shrinks the scope where the abnormal capacitors locate, which avoids calculating the total capacitances in MMCs. In the proposed capacitance calculation method, the complex operations are further saved. Both the two measures reduce the computation burden effectively. The implementation of the whole monitoring strategy is simple and fit for high-voltage MMCs. Moreover, the strategy has no adverse influence on the normal operation of MMCs. The effectiveness of the proposed strategy is verified by the simulation studies with the professional tool Matlab/Simulink.
21 January 2022 in IEEE Transactions on Power Delivery
Modular multilevel converters (MMCs) in high- voltage applications contain large numbers of power switches, which increases the fault probability inside MMCs. This paper proposes a detection method for the faulty arm containing switch open-circuit failures in high-voltage MMCs to improve the reliable operations of MMCs. The proposed method uses the periodicity of the deviation between the maximum and minimum capacitor voltages to provide the detection reference. To yield a reliable reference, the repetitive signal generator is employed. Then, the fault is identified by the difference between the referenced and measured capacitor voltage deviations. An auxiliary criterion is also designated to avoid the false detection caused by the mutations in MMCs. The proposed method can reduce the difficulty in the selection of thresholds. Moreover, the proposed method is robust in high-voltage MMCs with inferior capacitor voltage balancing performance, which ensures detection rapidity and accuracy. Finally, the feasibility of the method is verified by simulation results in Matlab/Simulink.
25 October 2024 in IEEE Transactions on Power Delivery
The submodule (SM) faults and DC faults are the key issues to the security and reliability of modular multilevel converters (MMCs) in high-voltage applications. In this paper, a novel submodule (SM) topology with SM fault tolerance and DC fault blocking is proposed to tackle different faults. Moreover, the diverse operation styles and related regulation methods are also designated for the new SM in various fault cases. In terms of SM fault tolerance, the method based on new SMs realizes the same functions as the conventional methods but affords better perform- ances, such as faster initiation, less operation interference, lower fault risk, easier realization and stronger fault-tolerant capability. Besides, the MMC containing the proposed SMs can clear the DC fault current effectively regardless of the normal mode or the fault-tolerant mode that the proposed SMs stay in. Furthermore, for the hybrid MMC, the proposed SMs are not only beneficial to lower the loss and cost, but also in favor of enhancing the fault- handling property. The operation feasibilities of the hybrid MMC containing the new SMs under different fault cases are verified by the simulation studies with Matlab/Simulink.