29 January 2020 in IEEE Transactions on Industrial Electronics
The uncertainty and disturbance estimator (UDE)-based controller has emerged as an effective robust control method to handle systems with uncertainties and disturbances. However, similar to other controllers including an integral action, the UDE-based controller faces the integral windup issue when the system has input constraints. In this paper, a bounded UDE-based controller is proposed to deal with systems subject to uncertainties, disturbances and input constraint. An additional time-varying variable is introduced into the design of the error dynamics to naturally avoid integral windup. The boundedness design guarantees that both the final controller output and the additional time-varying variable dynamically move on an ellipse so that the controller output always satisfies the input constraint. The proposed bounded UDE-based controller inherits the robustness of the conventional UDE-based control method, and has a clear structure, with guidelines provided for parameter selections. Both theoretical analysis and experimental results are provided to validate the proposed design.
1 April 2020 in Journal of Manufacturing Processes
9 December 2020 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
This article presents a control strategy to improve the energy efficiency of a quadrotor for field inspections. A power consumption analytical model for a quadrotor is constructed, which indicates that the power consumption of a quadrotor is correlated with the roll and pitch angles. Based on that, a cascaded bounded control framework is developed to regulate the roll and pitch angles within the predefined energy-efficient ranges, while a successful inspection trajectory tracking can be achieved simultaneously. Experimental studies are carried out to prove the effectiveness of the proposed method through a mock-up scenario of wind farm inspection. Compared to the conventional cascaded control framework, the proposed energy saving control strategy is capable of saving 5% energy for the same inspection assignment under wind disturbance.
2 July 2021 in IEEE Transactions on Applied Superconductivity
In order to improve the dynamic performance of the sensorless permanent magnet synchronous motor drive system, the modified pulsating high frequency voltage injection method is proposed. Firstly, the second order generalized integrator can be used to extract the high frequency voltage signal instead of band-pass filters. The specific frequency harmonic elimination unit is applied to obtain the rotor position error signal to avoid using the low-pass filter. Therefore, the system dynamic performance can be improved. In addition, the system parameter is easier to adjust than traditional methods with band-pass filters and low-pass filters. Finally, the simulation model and experimental platform are built to verify the effectiveness of the proposed method. The simulation and experimental results present that the dynamic performance of motor drive system can be improved.
24 November 2022 in IEEE Transactions on Transportation Electrification
Compared to a long-stator linear synchronous motor (LLSM), a long-stator doubly-fed linear motor (DFLM) exhibits two distinct advantages for high-speed maglev application: 1) It has two additional degrees of freedom with both the frequency and the phase angle of the mover to improve its control accuracy and dynamic responses; 2) It can use the slip power to feed the mover contactlessly and directly. In order to achieve the propulsion, the levitation, and the contactless power transfer through the common air-gap magnetic field, the “quasi-synchronous operation (QSO)” principle of the DFLM is proposed for high-speed maglev train. Based on the DFLM modeling and distinctive constraint analysis for high-speed maglev application, the performance evaluation of the DFLM is further investigated. To validate the feasibility of the DFLM application for high-speed maglev train, a unit DFLM prototype is designed and tested, and the corresponding simulation studies of the QSO control structure are provided with the comparison to the LLSM system.
6 May 2020 in IEEE Transactions on Control Systems Technology
In this brief, a bounded integral controller (BIC) with limited control power is proposed for a class of nonlinear multiple-input multiple-output (MIMO) systems. The sum-of-squares constraint on the control inputs with time-varying weights is studied and handled through the BIC design, which guarantees that both the control inputs and an auxiliary time-varying variable are dynamically constrained on a designed control circle. The BIC inherits the properties of the traditional integral controller to eliminate tracking errors and achieve disturbance rejections. Even under time-varying input weights, the BIC guarantees limited control power independently of both plant information and system states. The input-to-state (practical) stability of the closed-loop system is established. To demonstrate the effectiveness of the proposed method, experimental validations are conducted for two systems: a system with multiple dc motors subject to a power limit with time-varying input weights and a permanent magnet synchronous motor system subject to a voltage limit with time-invariant input weights.