Binglin Song

Dr. Binglin Song


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
BSBinglin Song
Binglin Song
GMGuoying Meng
Guoying Meng
WHWei Huang
Wei Huang
AWAiming Wang
Aiming Wang
XCXiaoHan Cheng
XiaoHan Cheng
JYJie Yang
Jie Yang
Given that two-phase closed thermosiphons (TPCT) are a prevalent and efficacious means of heat transfer. However, non-condensable gas (NCG) may potentially impact the heat transfer performance of the aforementioned devices. Nevertheless, the theoretical analysis of heat transfer in TPCT containing NCG is not fully comprehensive and therefore requires further supplementation by means of relevant experiments. This paper presents the development and experimental investigation of a theoretical heat transfer model for a TPCT containing NCG. The research encompasses the optimal fluid-filling ratio of R22 and R410a working fluid and the impact of NCG on heat transfer in the condenser section of TPCT. Experimental findings indicate that TPCT with R22 and R410a working fluids at a fluid-filling ratio of 60% and 50%, respectively, demonstrate excellent isotherm and heat transfer efficiency. The presence of NCG affects the condenser section heat transfer process of the vapor, leading to a 2 °C decrease in the average temperature of the condenser section of the TPCT (Tca). In comparison with the TPCT without NCG, it was observed that an increase in the mass of NCG from 0.0097 to 0.0197 mol resulted in a reduction in the effective length of the condenser section (La) and effective heat transfer rate (κ) of R22 TPCT. The decrease in La was 75.1 mm, while the decrease in κ was 15.02%. Furthermore, at the same NCG mass, the effective heat transfer rate of R410a TPCT is evidently superior to that of R22 TPCT. The NCG in the TPCT can be removed by using a check valve. Nevertheless, this will result in a reduction in the fluid-filling ratio of the TPCT. The temperature of the R410a TPCT containing 0.0197 mol NCG with a fluid-filling ratio of 50% is comparable to that observed in fluid-filling ratio of 40% after the NCG is exhausted.

12 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
BSBinglin Song
Binglin Song
GMGuoying Meng
Guoying Meng
AWAiming Wang
Aiming Wang
XCXiaoHan Cheng
XiaoHan Cheng
JYJie Yang
Jie Yang
In order to ensure the stability of the gravity heat pipe (GHP) heat exchanger in the mine return air waste heat recovery project and to explore the influence of the working fluid and filling ratio of the GHP on the heat transfer performance, this paper establishes a computational fluid dynamics (CFD) model of the GHP for mine return air waste heat recovery. The heat transfer characteristics and multiphase flow mechanism of the GHP with R22 and R410a working fluids at 30% to 80% filling ratios were studied using the VOF model from three aspects: two-phase flow, wall temperature, and thermal resistance. The validity of the model was verified through experimental data. The findings of the research indicate that the physical property parameters of the working fluid and the alterations in the filling ratio exert a substantial influence on the liquid-phase boiling heat transfer and the condensation process on the condenser wall. The CFD operation results demonstrate a high degree of congruence with the experimental data. The maximum deviation in the wall temperature is 2.9%. When the filling ratio is in the range of 50% to 60%, the axial distribution of the wall temperature tends to be flat. With regard to thermal resistance, both CFD and experimental results demonstrate a tendency of initially decreasing and subsequently increasing with increasing filling ratio. The average wall temperature of R410a GHP with a 50% filling ratio reached the highest value (20.3 °C), and the thermal resistance reached the lowest value (0.021 K/W), demonstrating superior heat transfer performance and excellent isothermal characteristics.