J. Jesús Villegas-Saucillo

Dr. J. Jesús Villegas-Saucillo

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NVNimrod Vazquez
Nimrod Vazquez
JVJ. Jesús Villegas-Saucillo
J. Jesús Villegas-Saucillo
CHClaudia Hernandez
Claudia Hernandez
ERElias Rodriguez
Elias Rodriguez
JAJaime Arau
Jaime Arau
An uninterruptible power supply (UPS) with high power factor and two conversion stages is suggested. The double-conversion configuration has three stages, but normally, only two stages are operating at the same time. The first stage of the proposed scheme integrates the power-factor-correction stage and the battery charger of the double-conversion configuration, obtaining a two-stage UPS. The second stage is based on the theory of inverter with boosting capabilities. The battery set has not only been completely isolated, but it has also been charged with a small change at the controller set point; these particular characteristics facilitate the system maintenance and simplify its operation. Additionally, the battery-set voltage is low, reducing the weight and size. The converter operation, analysis, design, and experimental results are shown. The proposed UPS approach is practical in low-power applications (les 500 W).

2 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JVJ. Jesús Villegas-Saucillo
J. Jesús Villegas-Saucillo
JDJavier Diaz-Carmona
Javier Diaz-Carmona
CCCarlos. A. Cerón-Álvarez
Carlos. A. Cerón-Álvarez
RJRaul Juárez-Aguirre
Raul Juárez-Aguirre
SDSaúl Domínguez-Nicolás
Saúl Domínguez-Nicolás
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
Oil and gas pipeline networks require the periodic inspection of their infrastructure, which can cause gas and oil leakage with several damages to the environment and human health. For this, non-destructive testing (NDT) techniques of low-cost and easy implementation are required. An option is the metal magnetic memory (MMM) method, which could be used for real-time monitoring defects of ferromagnetic structures based on the analysis of self-magnetic leakage fields distribution around each defect. This method only requires magnetic sensors with high resolution and a data processing system. We present a measurement system of tangential and normal MMM signals of three rectangular defects of an ASTM A-36 steel pipe. This system is formed by a magnetoresistive sensor, an Arduino nano and a virtual instrumentation. The measured magnetic signals have non-uniform distributions around the rectangular defects, which have small differences with respect to the results obtained of a 2D magnetic dipole model. The size of each rectangular defect is related to the amplitude and shape of its tangential and normal MMM signals. The proposed system could be used for real-time monitoring of the size and location of rectangular defects of ferromagnetic pipes. This system does not require expensive equipment, operators with high skill level or a special treatment of the ferromagnetic samples.

27 November 2024 in Technologies
Verified
Journal Article
Open access
PDF file
AAAdán Antonio Alonso
Adán Antonio Alonso
Alejandro Israel Barranco GutiérrezAlejandro Israel Barranco Gutiérrez
Alejandro Israel Barranco Gutiérrez
Iris Iddaly Méndez-GurrolaIris Iddaly Méndez-Gurrola
Iris Iddaly Méndez-Gurrola
MLMarcos Gutierrez Lopez
Marcos Gutierrez Lopez
JPJuan Prado-Olivarez
Juan Prado-Olivarez
CGCarlos Garcia-Capulin
Carlos Garcia-Capulin
Malaria is a significant global health issue, especially in tropical regions. Accurate and rapid diagnosis is critical for effective treatment and reducing mortality rates. Traditional diagnostic methods, like blood smear microscopy, are time-intensive and prone to error. This study introduces a deep learning approach for classifying malaria-infected cells in blood smear images using convolutional neural networks (CNNs); Six CNN models were designed and trained using a large labeled dataset of malaria cell images, both infected and uninfected, and were implemented on the Jetson TX2 board to evaluate them. The model was optimized for feature extraction and classification accuracy, achieving 97.72% accuracy, and evaluated using precision, recall, and F1-score metrics and execution time. Results indicate deep learning significantly improves diagnostic time efficiency on embedded systems. This scalable, automated solution is particularly useful in resource-limited areas without access to expert microscopic analysis. Future work will focus on clinical validation.

27 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JVJ. Jesús Villegas-Saucillo
J. Jesús Villegas-Saucillo
JDJavier Diaz-Carmona
Javier Diaz-Carmona
MEMarco A. Escarola-Rosas
Marco A. Escarola-Rosas
Hector Vazquez-LealHector Vazquez-Leal
Hector Vazquez-Leal
JMJaime Martinez-Castillo
Jaime Martinez-Castillo
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
Gas and oil pipeline networks require periodic inspections to detect cracks or notches that can cause industrial accidents and environmental contamination. For these inspections, the metal magnetic memory (MMM) method could be used as a non-destructive testing (NDT) technique, which does not need expensive equipment and high-skilled operators. However, more investigations are required to quantify the size and shape of defects in ferromagnetic pipes using the MMM signals. We present experimental measurements of MMM signals around five small V-shaped notches of an ASTM-A36 steel pipe using a three-axis magnetoresistive sensor. The V-shaped notches have different values of depth (500 µm, 1000 µm, 1500 µm, 2000 µm and 2500 µm) and width (1000 µm, 1500 µm, 2000 µm, 3000 µm and 3500 µm). We measured the variations of tangential and normal MMM signals around these defects and their relationships with the size of each defect. The first V-notch defect (500 μm depth and 1000 μm width) registers variations of the tangential and normal MMM signals of 14.32 μT ± 1.62 μT and 27.95 μT ± 1.14 μT, respectively. On the other hand, the fifth V-notch defect (2500 μm depth and 3500 μm width) has variations of the tangential and normal MMM signals of 68.75 μT ± 1.10 μT and 71.37 μT ± 0.72 μT, respectively. The MMM method could be used for real-time monitoring of V-shaped notches in steel pipes. This method does not require special treatment of steel pipes.

30 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JGJuan Carlos Gómez-Cortés
Juan Carlos Gómez-Cortés
JDJavier Diaz-Carmona
Javier Diaz-Carmona
Alejandro Israel Barranco GutiérrezAlejandro Israel Barranco Gutiérrez
Alejandro Israel Barranco Gutiérrez
Jose Alfredo Padilla-MedinaJose Alfredo Padilla-Medina
Jose Alfredo Padilla-Medina
AAAdán Antonio Alonso
Adán Antonio Alonso
JPJuan Prado-Olivarez
Juan Prado-Olivarez
This paper presents a prototype of a portable and modular electrical impedance tomography (EIT) system for breast tumor detection. The proposed system uses MATLAB to generate three-dimensional representations of breast tissue. The modular architecture of the system allows for flexible customization and scalability. It consists of several interconnected modules. Each module can be easily replaced or upgraded, facilitating system maintenance and future enhancements. Testing of the prototype has shown promising results in preliminary screening based on experimental studies. Agar models were used for the experimental stage of this project. The 3D representations provide clinicians with valuable information for accurate diagnosis and treatment planning. Further research and refinement of the system is warranted to validate its performance in future clinical trials.

19 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JVJ. Jesús Villegas-Saucillo
J. Jesús Villegas-Saucillo
JDJavier Diaz-Carmona
Javier Diaz-Carmona
JPJuan Prado-Olivarez
Juan Prado-Olivarez
Monserrat Sofía López-CornejoMonserrat Sofía López-Cornejo
Monserrat Sofía López-Cornejo
EEErnesto Alberto Elvira-Hernandez
Ernesto Alberto Elvira-Hernandez
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
Ferromagnetic pipes are widely used for fluid transportation in various industries. The failure of these ferromagnetic pipes due to surface defects can generate industrial accidents, economic losses, and environmental pollution. Non-destructive testing techniques are required to detect these surface defects. An alternative is the metal magnetic memory (MMM) method, which can be employed to detect surface flaws in ferromagnetic structures. Based on this method, we present an analysis of experimental results of the magnetic field variations around five different surface semi-elliptical defects of an ASTM A36 steel pipe. A measurement system of MMM signals is implemented with a rotatory mechanism, a magnetoresistive sensor, a data processing unit, and a control digital unit. The MMM method does not require expensive equipment or special treatment of the ferromagnetic structures. In order to research a potential relationship between the defect sample size and the measured MMM signals, variable defect dimensions are experimentally considered. According to these results, the shape and magnitude of the normal and tangential MMM signals are altered by the superficial semi-elliptical defects. In particular, the maximum and mean tangential components and the maximum and minimum normal components are related to the defect dimensions. The proposed measurement system can be used to study the behavior of magnetic field variations around surface defects of ferromagnetic pipes. This system can be adapted to measure the position and damage level of small defects on the surface of ferromagnetic pipes.