Inchan Youn

Dr. Inchan Youn


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Molecular Therapy
Verified
Journal Article
Open access
SLSo Jin Lee
So Jin Lee
ALAeju Lee
Aeju Lee
SHSeung Rim Hwang
Seung Rim Hwang
JPJong-Sung Park
Jong-Sung Park
JJJiyeon Jang
Jiyeon Jang
KKKwangmeyung Kim
Kwangmeyung Kim
Among various proinflammatory cytokines involved in the pathogenesis of rheumatoid arthritis (RA), tumor necrosis factor (TNF)-α plays a pivotal role in the release of other cytokines and induction of chronic inflammation. Even though siRNA has the therapeutic potential, they have a challenge to be delivered into the target cells because of their poor stability in physiological fluids. Herein, we design a nanocomplex of polymerized siRNA (poly-siRNA) targeting TNF-α with thiolated glycol chitosan (tGC) polymers for the treatment of RA. Poly-siRNA is prepared through self-polymerization of thiol groups at the 5' end of sense and antisense strand of siRNA and encapsulated into tGC polymers, resulting in poly-siRNA-tGC nanoparticles (psi-tGC-NPs) with an average diameter of 370 nm. In the macrophage culture system, psi-tGC-NPs exhibit rapid cellular uptake and excellent in vitro TNF-α gene silencing efficacy. Importantly, psi-tGC-NPs show the high accumulation at the arthritic joint sites in collagen-induced arthritis (CIA) mice. Treatment monitoring data obtained by the matrix metalloproteinase 3-specific nanoprobe and microcomputed tomography show that intravenous injection of psi-tGC-NPs significantly inhibits inflammation and bone erosion in CIA mice, comparable to methotrexate (5 mg/kg). Therefore, the availability of psi-tGC-NP therapy that target specific cytokines may herald new era in the treatment of RA.

9 May 2019 in ACS Nano
Verified
Journal Article
Closed access
SKSun Hong Kim
Sun Hong Kim
HSHyunseon Seo
Hyunseon Seo
JKJiheong Kang
Jiheong Kang
JHJaeyoung Hong
Jaeyoung Hong
DSDuhwan Seong
Duhwan Seong
Donghee SonDonghee Son
Donghee Son

21 August 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
KSKang-Il Song
Kang-Il Song
HSHyunseon Seo
Hyunseon Seo
DSDuhwan Seong
Duhwan Seong
SKSeunghoe Kim
Seunghoe Kim
KYKi Jun Yu
Ki Jun Yu
Donghee SonDonghee Son
Donghee Son
Realizing a clinical-grade electronic medicine for peripheral nerve disorders is challenging owing to the lack of rational material design that mimics the dynamic mechanical nature of peripheral nerves. Electronic medicine should be soft and stretchable, to feasibly allow autonomous mechanical nerve adaptation. Herein, we report a new type of neural interface platform, an adaptive self-healing electronic epineurium (A-SEE), which can form compressive stress-free and strain-insensitive electronics-nerve interfaces and enable facile biofluid-resistant self-locking owing to dynamic stress relaxation and water-proof self-bonding properties of intrinsically stretchable and self-healable insulating/conducting materials, respectively. Specifically, the A-SEE does not need to be sutured or glued when implanted, thereby significantly reducing complexity and the operation time of microneurosurgery. In addition, the autonomous mechanical adaptability of the A-SEE to peripheral nerves can significantly reduce the mechanical mismatch at electronics-nerve interfaces, which minimizes nerve compression-induced immune responses and device failure. Though a small amount of Ag leaked from the A-SEE is observed in vivo (17.03 ppm after 32 weeks of implantation), we successfully achieved a bidirectional neural signal recording and stimulation in a rat sciatic nerve model for 14 weeks. In view of our materials strategy and in vivo feasibility, the mechanically adaptive self-healing neural interface would be considered a new implantable platform for a wide range application of electronic medicine for neurological disorders in the human nervous system.

21 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Ahnsei ShonAhnsei Shon
Ahnsei Shon
JCJun-Uk Chu
Jun-Uk Chu
JJJiuk Jung
Jiuk Jung
Hyungmin KimHyungmin Kim
Hyungmin Kim
IYInchan Youn
Inchan Youn
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

22 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JSJoohwan Sung
Joohwan Sung
SHSungmin Han
Sungmin Han
HPHeesu Park
Heesu Park
HCHyun-Myung Cho
Hyun-Myung Cho
SHSoree Hwang
Soree Hwang
IYInchan Youn
Inchan Youn
The joint angle during gait is an important indicator, such as injury risk index, rehabilitation status evaluation, etc. To analyze gait, inertial measurement unit (IMU) sensors have been used in studies and continuously developed; however, they are difficult to utilize in daily life because of the inconvenience of having to attach multiple sensors together and the difficulty of long-term use due to the battery consumption required for high data sampling rates. To overcome these problems, this study propose a multi-joint angle estimation method based on a long short-term memory (LSTM) recurrent neural network with a single low-frequency (23 Hz) IMU sensor. IMU sensor data attached to the lateral shank were measured during overground walking at a self-selected speed for 30 healthy young persons. The results show a comparatively good accuracy level, similar to previous studies using high-frequency IMU sensors. Compared to the reference results obtained from the motion capture system, the estimated angle coefficient of determination (R2) is greater than 0.74, and the root mean square error and normalized root mean square error (NRMSE) are less than 7° and 9.87%, respectively. The knee joint showed the best estimation performance in terms of the NRMSE and R2 among the hip, knee, and ankle joints.

11 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HCHyun Myung Cho
Hyun Myung Cho
HPHeesu Park
Heesu Park
Suh-Yeon DongSuh-Yeon Dong
Suh-Yeon Dong
IYInchan Youn
Inchan Youn
The goals of this study are the suggestion of a better classification method for detecting stressed states based on raw electrocardiogram (ECG) data and a method for training a deep neural network (DNN) with a smaller data set. We suggest an end-to-end architecture to detect stress using raw ECGs. The architecture consists of successive stages that contain convolutional layers. In this study, two kinds of data sets are used to train and validate the model: A driving data set and a mental arithmetic data set, which smaller than the driving data set. We apply a transfer learning method to train a model with a small data set. The proposed model shows better performance, based on receiver operating curves, than conventional methods. Compared with other DNN methods using raw ECGs, the proposed model improves the accuracy from 87.39% to 90.19%. The transfer learning method improves accuracy by 12.01% and 10.06% when 10 s and 60 s of ECG signals, respectively, are used in the model. In conclusion, our model outperforms previous models using raw ECGs from a small data set and, so, we believe that our model can significantly contribute to mobile healthcare for stress management in daily life.