Balázs Patczai

Dr. Balázs Patczai

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2016 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
TMTibor Mintál
Tibor Mintál
BPBalázs Patczai
Balázs Patczai
NWNorbert Wiegand
Norbert Wiegand
LKLászló Kereskai
László Kereskai
JVJózsef Váncsodi
József Váncsodi
Dénes LőrinczyDénes Lőrinczy
Dénes Lőrinczy

24 April 2024 in Polymers
Verified
Journal Article
Open access
PDF file
BJBertalan Jillek
Bertalan Jillek
PSPéter Szabó
Péter Szabó
JKJudit Kopniczky
Judit Kopniczky
OKOlga Krafcsik
Olga Krafcsik
ISIstván Szabó
István Szabó
Kinga TurzóKinga Turzó
Kinga Turzó
The goal of the study was to compare the surface characteristics of typical implant materials used in orthopedic surgery and traumatology, as these determine their successful biointegration. The morphological and chemical structure of Vortex plate anodized titanium from commercially pure (CP) Grade 2 Titanium (Ti2) is generally used in the following; non-cemented total hip replacement (THR) stem and cup Ti alloy (Ti6Al4V) with titanium plasma spray (TPS) coating; cemented THR stem Stainless steel (SS); total knee replacement (TKR) femoral component CoCrMo alloy (CoCr); cemented acetabular component from highly cross-linked ultrahigh molecular weight polyethylene (HXL); and cementless acetabular liner from ultrahigh molecular weight polyethylene (UHMWPE) (Sanatmetal, Ltd., Eger, Hungary) discs, all of which were examined. Visualization and elemental analysis were carried out by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). Surface roughness was determined by atomic force microscopy (AFM) and profilometry. TPS Ti presented the highest Ra value (25 ± 2 μm), followed by CoCr (535 ± 19 nm), Ti2 (227 ± 15 nm) and SS (170 ± 11 nm). The roughness measured in the HXL and UHMWPE surfaces was in the same range, 147 ± 13 nm and 144 ± 15 nm, respectively. EDS confirmed typical elements regarding the investigated prosthesis materials. XPS results supported the EDS results and revealed a high % of Ti4+ on Ti2 and TPS surfaces. The results indicate that the surfaces of prosthesis materials have significantly different features, and a detailed characterization is needed to successfully apply them in orthopedic surgery and traumatology.

Verified
Journal Article
Open access
PDF file
VSValentin Schmidt
Valentin Schmidt
PBPolgár Beáta
Polgár Beáta
VCVanda Agnes Cziger-Nemes
Vanda Agnes Cziger-Nemes
TDTímea Dergez
Tímea Dergez
LJLászló Janovák
László Janovák
BPBalázs Patczai
Balázs Patczai
Bioactive glass materials have been used for decades in orthopedic surgery, traumatology, and oral and maxillofacial surgery to repair bone defects. This study aimed to evaluate in vitro the survival and proliferation of MG63 human osteosarcoma-derived cells on S53P4 bioactive glass (BonAlive® granules). Microscopic visualization was performed to directly observe the interactions between the cells and the material. Osteoblast-like cells were examined on non-adherent test plates, on tissue culture (TC)-treated plates and on the surface of the bioglass to assess the differences. Cell survival and proliferation were monitored using a CCK-8 optical density assay. Comparing the mean OD of MG63 cells in MEM on TC-treated plates with cells on BG, we detected a significant difference (p < 0.05), over each time of observation. The sustained cell proliferation confirmed the non-cytotoxic property of the bioglass, as the cell number increased continuously at 48, 72, 96, and 168 h and even did not plateau after 168 h. Since the properties of bioglasses can vary significantly depending on their composition and environment, a thorough characterization of their biocompatibility is crucial to ensure their effective and appropriate application—for example, during hip and knee prosthesis insertion.

15 May 2024 in Magyar Traumatológia Ortopédia Kézsebészet Plasztikai Sebészet
Verified
Journal Article
Open access
PDF file
NWNorbert Wiegand
Norbert Wiegand
GBGábor Bűcs
Gábor Bűcs
BPBalázs Patczai
Balázs Patczai
This case report presents a traumatic intra-articular patellar dislocation – associated intercondylar fracture of the distal femur – and the consequent arthroscope assisted reduction and percutaneous screw fixation. To the best of our knowledge, this is the first case in which the arthroscope assisted operative reduction and percutaneous screw fixation of the fracture fragment has been demonstrated. Our patient was a 55-year-old female who was treated by the aforementioned method which concluded with excellent results.

9 September 2025
Verified
Book Chapter
Closed access
PDF file
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
PKPravin Kumar
Pravin Kumar
ÁSÁdám Tibor Schlégl
Ádám Tibor Schlégl
Peter MarotiPeter Maroti
Peter Maroti
VCVanda Agnes Cziger-Nemes
Vanda Agnes Cziger-Nemes
LTLuca Toth
Luca Toth
The chapter discusses the integration of additive manufacturing (AM) technologies in fabricating personalized implantable prosthetics. It highlights the evolution and expansion of three-dimensional (3D) printing in medical applications, such as orthopedics, neurosurgery, dentistry, and reconstructive surgery. Various AM techniques, such as laser powder bed fusion, electron beam melting, and stereolithography, have facilitated the production of complex structures tailored to individual patient needs. Key advancements include the development of biocompatible materials like titanium and polyether ether ketone (PEEK), as well as surface modifications that enhance osseointegration. Additionally, emerging technologies such as 4D printing and smart sensors are explored for their potential in further optimizing prosthetic functionality and real-time monitoring of implants. Despite these innovations, challenges remain in terms of regulatory approval, cost reduction, and ensuring long-term clinical safety. The document stresses the importance of multidisciplinary collaboration among medical professionals, engineers, and biotechnologists to advance the field of implantable prosthetics. <!----> <!----> <!----> <!---->

11 March 2026 in Medicina
Verified
Journal Article
Open access
PDF file
DWDorottya Zsuzsanna Wiegand
Dorottya Zsuzsanna Wiegand
EMEszter Dr. Mikó-Baráth Mikó-Baráth
Eszter Dr. Mikó-Baráth Mikó-Baráth
ITIldikó Telkes
Ildikó Telkes
BPBalázs Patczai
Balázs Patczai
CACsutak Adrienne
Csutak Adrienne
VCVanda Agnes Cziger-Nemes
Vanda Agnes Cziger-Nemes
Background and Objectives: Visual impairment and reduced stereovision significantly impact the quality of life and increase fall risk in older adults. While standard clinical assessment of visual functions is essential in this population, its use is often limited by the need for specialized equipment and trained personnel. Tablet-based screening tools offer a practical alternative but require clinical validation. This study aimed to assess the agreement, reliability, and diagnostic performance of a tablet-based screening application (index methods) compared to established clinical reference methods for assessing visual acuity (VA) and stereovision (SV) in adults over 60 years. Materials and Methods: This prospective, non-blinded, cross-sectional, feasibility study included two cohorts: a test–retest group of 24 older adults assessed twice within 7 days, and a clinical cross-sectional group of 135 participants recruited from primary care practices. VA was measured using tablet-based Landolt C test and compared with an ETDRS-style chart, while stereovision was assessed using tablet-based static and dynamic random dot stereograms and compared with the TNO stereotest. Agreement and reliability were evaluated using Bland–Altman analysis, intraclass correlation coefficients (ICC), and receiver operating characteristic (ROC) curves. Results: The index VA method demonstrated good test–retest reliability (ICC = 0.79) with no significant difference between repeated measurements. In the clinical cross-sectional group, visual acuity measurements showed a small mean bias (0.022 logMAR) between the index and reference methods, which remained within clinically acceptable limits, particularly in the intermediate acuity range. For stereovision, the index SV tests showed high test–retest agreement. Using a TNO cutoff of 480 arcsec, the index SV method demonstrated good diagnostic accuracy (AUC 0.87 for static and 0.85 for dynamic stimuli) with high sensitivity for detecting impaired stereovision. Conclusions: The tablet-based index method provided reliable and clinically comparable results for VA and SV assessments in older adults, supporting its potential use as a screening tool in primary care and community-based settings.