The goal of the study was to compare the surface characteristics of typical implant materials used in orthopedic surgery and traumatology, as these determine their successful biointegration. The morphological and chemical structure of Vortex plate anodized titanium from commercially pure (CP) Grade 2 Titanium (Ti2) is generally used in the following; non-cemented total hip replacement (THR) stem and cup Ti alloy (Ti6Al4V) with titanium plasma spray (TPS) coating; cemented THR stem Stainless steel (SS); total knee replacement (TKR) femoral component CoCrMo alloy (CoCr); cemented acetabular component from highly cross-linked ultrahigh molecular weight polyethylene (HXL); and cementless acetabular liner from ultrahigh molecular weight polyethylene (UHMWPE) (Sanatmetal, Ltd., Eger, Hungary) discs, all of which were examined. Visualization and elemental analysis were carried out by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). Surface roughness was determined by atomic force microscopy (AFM) and profilometry. TPS Ti presented the highest Ra value (25 ± 2 μm), followed by CoCr (535 ± 19 nm), Ti2 (227 ± 15 nm) and SS (170 ± 11 nm). The roughness measured in the HXL and UHMWPE surfaces was in the same range, 147 ± 13 nm and 144 ± 15 nm, respectively. EDS confirmed typical elements regarding the investigated prosthesis materials. XPS results supported the EDS results and revealed a high % of Ti4+ on Ti2 and TPS surfaces. The results indicate that the surfaces of prosthesis materials have significantly different features, and a detailed characterization is needed to successfully apply them in orthopedic surgery and traumatology.
Bioactive glass materials have been used for decades in orthopedic surgery, traumatology, and oral and maxillofacial surgery to repair bone defects. This study aimed to evaluate in vitro the survival and proliferation of MG63 human osteosarcoma-derived cells on S53P4 bioactive glass (BonAlive® granules). Microscopic visualization was performed to directly observe the interactions between the cells and the material. Osteoblast-like cells were examined on non-adherent test plates, on tissue culture (TC)-treated plates and on the surface of the bioglass to assess the differences. Cell survival and proliferation were monitored using a CCK-8 optical density assay. Comparing the mean OD of MG63 cells in MEM on TC-treated plates with cells on BG, we detected a significant difference (p < 0.05), over each time of observation. The sustained cell proliferation confirmed the non-cytotoxic property of the bioglass, as the cell number increased continuously at 48, 72, 96, and 168 h and even did not plateau after 168 h. Since the properties of bioglasses can vary significantly depending on their composition and environment, a thorough characterization of their biocompatibility is crucial to ensure their effective and appropriate application—for example, during hip and knee prosthesis insertion.
15 May 2024 in Magyar Traumatológia Ortopédia Kézsebészet Plasztikai Sebészet
This case report presents a traumatic intra-articular patellar dislocation – associated intercondylar fracture of the distal femur – and the consequent arthroscope assisted reduction and percutaneous screw fixation. To the best of our knowledge, this is the first case in which the arthroscope assisted operative reduction and percutaneous screw fixation of the fracture fragment has been demonstrated. Our patient was a 55-year-old female who was treated by the aforementioned method which concluded with excellent results.
The chapter discusses the integration of additive manufacturing (AM) technologies in fabricating personalized implantable prosthetics. It highlights the evolution and expansion of three-dimensional (3D) printing in medical applications, such as orthopedics, neurosurgery, dentistry, and reconstructive surgery. Various AM techniques, such as laser powder bed fusion, electron beam melting, and stereolithography, have facilitated the production of complex structures tailored to individual patient needs. Key advancements include the development of biocompatible materials like titanium and polyether ether ketone (PEEK), as well as surface modifications that enhance osseointegration. Additionally, emerging technologies such as 4D printing and smart sensors are explored for their potential in further optimizing prosthetic functionality and real-time monitoring of implants. Despite these innovations, challenges remain in terms of regulatory approval, cost reduction, and ensuring long-term clinical safety. The document stresses the importance of multidisciplinary collaboration among medical professionals, engineers, and biotechnologists to advance the field of implantable prosthetics. <!----> <!----> <!----> <!---->
Background and Objectives: Visual impairment and reduced stereovision significantly impact the quality of life and increase fall risk in older adults. While standard clinical assessment of visual functions is essential in this population, its use is often limited by the need for specialized equipment and trained personnel. Tablet-based screening tools offer a practical alternative but require clinical validation. This study aimed to assess the agreement, reliability, and diagnostic performance of a tablet-based screening application (index methods) compared to established clinical reference methods for assessing visual acuity (VA) and stereovision (SV) in adults over 60 years. Materials and Methods: This prospective, non-blinded, cross-sectional, feasibility study included two cohorts: a test–retest group of 24 older adults assessed twice within 7 days, and a clinical cross-sectional group of 135 participants recruited from primary care practices. VA was measured using tablet-based Landolt C test and compared with an ETDRS-style chart, while stereovision was assessed using tablet-based static and dynamic random dot stereograms and compared with the TNO stereotest. Agreement and reliability were evaluated using Bland–Altman analysis, intraclass correlation coefficients (ICC), and receiver operating characteristic (ROC) curves. Results: The index VA method demonstrated good test–retest reliability (ICC = 0.79) with no significant difference between repeated measurements. In the clinical cross-sectional group, visual acuity measurements showed a small mean bias (0.022 logMAR) between the index and reference methods, which remained within clinically acceptable limits, particularly in the intermediate acuity range. For stereovision, the index SV tests showed high test–retest agreement. Using a TNO cutoff of 480 arcsec, the index SV method demonstrated good diagnostic accuracy (AUC 0.87 for static and 0.85 for dynamic stimuli) with high sensitivity for detecting impaired stereovision. Conclusions: The tablet-based index method provided reliable and clinically comparable results for VA and SV assessments in older adults, supporting its potential use as a screening tool in primary care and community-based settings.