Dongsheng He

Dr. Dongsheng He

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
DHDongsheng He
Dongsheng He
ZJZhi-Dong Jia
Zhi-Dong Jia
JWJi-Xiang Wang
Ji-Xiang Wang
JFJian-Bing Fu
Jian-Bing Fu
FHFawu He
Fawu He
FDFeng Dai
Feng Dai

9 April 2024 in International Journal of Emerging Electric Power Systems
Verified
Journal Article
Closed access
DHDongsheng He
Dongsheng He
ZJZhi-Dong Jia
Zhi-Dong Jia
YYYong-Gang Yue
Yong-Gang Yue
JWJi-Xiang Wang
Ji-Xiang Wang
LXLiu-Rang Xiong
Liu-Rang Xiong
FHFa-Wu He
Fa-Wu He
The temperature distribution characteristics of dry-type distribution transformers reflect their overall performance and quality. Distribution transformer daily load changes dramatically, its temperature fluctuates within a certain range. However, most of the research results on transformer temperature rise focus on the steady-state temperature characteristics of transformers, and lack of research related to dynamic temperature rise characteristics. This paper carries out a multi-physics coupling simulation and experimental verification of the dynamic temperature rise relaxation characteristics. The simulation uses the “electromagnetic-flow-thermal” multi-physics coupling analysis method to simulate the steady-state temperature rise characteristics and dynamic temperature rise relaxation characteristics of windings under different load rates. Then, this paper also explores the correlation between the dynamic temperature rise relaxation characteristics and load rate at the typical positions of high-voltage windings and low-voltage windings. The results show that the temperature rise of the winding shows the law of increasing the saturation index function with the increase of the load application time at any load rate. A quantitative characterization model of dynamic temperature rise relaxation behavior at different positions of transformer windings is constructed. It is found that the steady-state temperature rise value of different parts of the winding increases regularly as a power function with the increase of load rate, while the constant value of dynamic temperature rise relaxation time in different parts of the winding decreases as a power function with the increase of load rate. The verification results of the quantitative characterization model of dynamic temperature rise relaxation behavior show that the maximum error of the measured and theoretical steady-state temperature rise value is only 1.56 K, and the maximum error of the constant value of dynamic temperature rise relaxation time is only 0.082 h. These findings provide valuable insights into the performance and quality of dry-type distribution transformers, and can help improve their design and operation for better efficiency and safety.

27 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
FJFu Jianbing
Fu Jianbing
YGYanfeng Gao
Yanfeng Gao
LWLiming Wang
Liming Wang
YLYi Lu
Yi Lu
FYFanghui Yin
Fanghui Yin
KWKang Wang
Kang Wang
Silicone rubber optical fiber composite insulators introduce interface defects due to embedded optical fibers, and their structural design remains immature, resulting in inadequate interface sealing performance. In actual operation, the combined effects of high electric fields, high humidity and heat, and mechanical loads lead to frequent failures. This study proposes replacing conventional silicone rubber with cycloaliphatic epoxy resin (CEP), which exhibits superior aging resistance, to enhance long-term operational reliability. However, the correlation mechanism between the structural parameters of CEP optical fiber insulators and their electromechanical properties remains unclear, lacking corresponding design basis. Therefore, based on finite element simulation technology, this study systematically analyzed the influence patterns of core rod diameter, fiber implantation method, spiral groove angle, fiber implantation quantity, and voltage equalization ring structural parameters (outer diameter, circular tube radius, shielding depth) on their mechanical and electrical properties. Research findings indicate that in terms of mechanical properties, the helical groove structure with a 40 mm core rod diameter, a groove angle of 135°, and six embedded optical fibers exhibits the lowest optical fiber strain. In terms of electrical performance, the minimum peak electric field strength at the end of the insulator occurs when the equalizing ring has an outer diameter of 370 mm, the circular tube radius is 25 mm, and the shielding depth is 50 mm, reaching only 4.6 kV/cm, which meets the requirements of DL/T 1000.3-2015. This study establishes optimization principles for key structural parameters of CEP optical fiber composite insulators, offering significant engineering value for enhancing the overall performance of optical fiber composite insulators and improving the operational safety of power systems.