Rosalyne Westley

Dr. Rosalyne Westley

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2023 in Radiotherapy and Oncology
Verified
Journal Article
Open access
GSGillian Adair Smith
Gillian Adair Smith
ADAlex Dunlop
Alex Dunlop
SASophie Alexander
Sophie Alexander
HBHelen Barnes
Helen Barnes
FCFrancis Casey
Francis Casey
HMHelen A. McNair
Helen A. McNair
The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers’ roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. Comparison of the radiographers’ and clinicians’ contours resulted in a median (range) DSC of 0.92 (0.86 – 0.99), median (range) MDA of 0.98 mm (0.2–1.7) and median (range) HD of 6.3 mm (2.5–11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians’ offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88–1.0), median (range) MDA was 0.8 mm (0.04–1.18) and HD was 5.15 mm (2.09–8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians’ offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.

4 June 2024 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
RWRosalyne Westley
Rosalyne Westley
SASophie Alexander
Sophie Alexander
EGEdmund Goodwin
Edmund Goodwin
ADAlex Dunlop
Alex Dunlop
SNSimeon Nill
Simeon Nill
Alison TreeAlison Tree
Alison Tree
Introduction: We aimed to establish if stereotactic body radiotherapy to the prostate can be delivered safely using reduced clinical target volume (CTV) to planning target volume (PTV) margins on the 1.5T MR-Linac (MRL) (Elekta, Stockholm, Sweden), in the absence of gating.Methods: Cine images taken in 3 orthogonal planes during the delivery of prostate SBRT with 36.25 Gray (Gy) in 5 fractions on the MRL were analysed. Using the data from 20 patients, the percentage of radiotherapy (RT) delivery time where the prostate position moved beyond 1, 2, 3, 4 and 5 mm in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) and any direction was calculated.Results: The prostate moved less than 3 mm in any direction for 90% of the monitoring period in 95% of patients. On a per-fraction basis, 93% of fractions displayed motion in all directions within 3 mm for 90% of the fraction delivery time. Recurring motion patterns were observed showing that the prostate moved with shallow drift (most common), transient excursions and persistent excursions during treatment.Conclusion: A 3 mm CTV-PTV margin is safe to use for the treatment of 5 fraction prostate SBRT on the MRL, without gating. In the context of gating this work suggests that treatment time will not be extensively lengthened when an appropriate gating window is applied.

8 March 2023 in Clinical and Translational Radiation Oncology
Verified
Journal Article
Open access
LBLuca Boldrini
Luca Boldrini
FAFilippo Alongi
Filippo Alongi
ARAngela Romano
Angela Romano
DDDiepriye Charles Davies
Diepriye Charles Davies
MBMichael Bassetti
Michael Bassetti
LNLuca Nicosia
Luca Nicosia
The introduction of on-line magnetic resonance image-guided radiotherapy (MRIgRT) has led to an improvement in the therapeutic workflow of radiotherapy treatments thanks to the better visualization of therapy volumes assured by the higher soft tissue contrast. Magnetic Resonance contrast agents (MRCA) could improve the target delineation in on-line MRIgRT planning as well as reduce inter-observer variability and enable innovative treatment optimization protocols. The aim of this survey is to investigate the utilization of MRCA among centres that clinically implemented on-line MRIgRT technology. In September 2021, we conducted an online survey consisting of a sixteen-question questionnaire that was distributed to the all the hospitals around the world equipped with MR Linacs. The questionnaire was developed by two Italian 0.35 T and 1.5 T MR-Linac centres and was validated by four other collaborating centres, using a Delphi consensus methodology. The survey was distributed to 52 centres and 43 centres completed it (82.7%). Among these centres, 23 institutions (53.5%) used the 0.35T MR-Linac system, while the remaining 20 (46.5%) used the 1.5T MR-Linac system.According to results obtained, 25 (58%) of the centres implemented the use of MRCA for on-line MRIgRT. Gadoxetate (Eovist®; Primovist®) was reported to be the most used MRCA (80%) and liver the most common site of application (58%). Over 70% of responders agreed/strongly agreed to the need for international guidelines. The use of MRCA in clinical practice presents several pitfalls and future research will be necessary to understand the actual advantage derived from the use of MRCA in clinical practice, their toxicity profiles and better define the need of formulating guidelines for standardising the use of MRCA in MRIgRT workflow.

30 May 2024 in Cancers
Verified
Journal Article
Open access
PDF file
RWRosalyne Westley
Rosalyne Westley
FCFrancis Casey
Francis Casey
RMRobert Adam Mitchell
Robert Adam Mitchell
SASophie Alexander
Sophie Alexander
SNSimeon Nill
Simeon Nill
Alison TreeAlison Tree
Alison Tree
HERMES is a phase II trial of MRI-guided daily-adaptive radiotherapy (MRIgART) randomising men with localised prostate cancer to either 2-fractions of SBRT with a boost to the tumour or 5-fraction SBRT. In the context of this highly innovative regime the dose delivered must be carefully considered. The first ten patients recruited to HERMES were analysed in order to establish the dose received by the targets and organs at risk (OARS) in the context of intrafraction motion. A regression analysis was performed to measure how the volume of air within the rectum might further impact rectal dose secondary to the electron return effect (ERE). One hundred percent of CTV target objectives were achieved on the MRI taken prior to beam-on-time. The post-delivery MRI showed that high-dose CTV coverage was achieved in 90% of sub-fractions (each fraction is delivered in two sub-fractions) in the 2-fraction cohort and in 88% of fractions the 5-fraction cohort. Rectal D1 cm3 was the most exceeded constraint; three patients exceeded the D1 cm3 < 20.8 Gy in the 2-fraction cohort and one patient exceeded the D1 cm3 < 36 Gy in the 5-fraction cohort. The volume of rectal gas within 1 cm of the prostate was directly proportional to the increase in rectal D1 cm3, with a strong (R = 0.69) and very strong (R = 0.90) correlation in the 2-fraction and 5-fraction cohort respectively. Dose delivery specified in HERMES is feasible, although for some patients delivered doses to both target and OARs may vary from those planned.