Nooranida Arifin

Dr. Nooranida Arifin


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
HGHossein Gholizadeh
Hossein Gholizadeh
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
AEArezoo Eshraghi
Arezoo Eshraghi
SASadeeq Ali
Sadeeq Ali
NANooranida Arifin
Nooranida Arifin
WAWan Abu Bakar Wan Abas
Wan Abu Bakar Wan Abas
Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems). All the suspension systems were tested (tensile testing machine) in terms of the degree of the shear strength and the patient’s comfort. Nine transtibial amputees participated in this study. The patients were asked to use four different suspension systems. Afterwards, each participant completed a questionnaire for each system to evaluate their comfort. Furthermore, the systems were compared in terms of the cost. The maximum tensile load that the new system could bear was 490 N (SD, 5.5) before the system failed. Pin/lock, magnetic and suction suspension systems could tolerate loads of580 N (SD, 8.5), 350.9 (SD, 7) and 310 N (SD, 8.4), respectively. Our subjects were satisfied with the new hook and loop system, particularly in terms of easy donning and doffing. Furthermore, the new system is considerably cheaper (35 times) than the current locking systems in the market. The new suspension system could successfully retain the prosthesis on the residual limb as a good alternative for lower limb amputees. In addition, the new system addresses some problems of the existing systems and is more cost effective than its counterparts.

26 October 2017 in Malaysian Journal of Medical Sciences
Verified
Journal Article
Closed access
NANooranida Arifin
Nooranida Arifin
HHHasif Rafidee Hasbollah
Hasif Rafidee Hasbollah
MHMuhd Hafiz Hanafi
Muhd Hafiz Hanafi
AIAl Hafiz Ibrahim
Al Hafiz Ibrahim
WRWan Afezah Wan Abdul Rahman
Wan Afezah Wan Abdul Rahman
RARoslizawati Che Aziz
Roslizawati Che Aziz
The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved.

4 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
JLJingjing Liu
Jingjing Liu
MNMuhammad Awais Naeem
Muhammad Awais Naeem
MKMouaz Al Kouzbary
Mouaz Al Kouzbary
HKHamza Al Kouzbary
Hamza Al Kouzbary
HMHanie Nadia Malaya
Hanie Nadia Malaya
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
3D printing is the most suitable method to manufacture the frame parts of powered ankle-foot prostheses but the compressive strength of the 3D-printed part needs to be ensured. According to the compression test standard ASTM D695, the effect of infill pattern and density, which is transferred to the mass of the standard specimen, on the compressive strength is investigated with a carbon fiber-reinforced nylon material. With the same infill pattern, specimens with more mass have a higher compressive strength. With the same mass, specimens with triangular fill have a higher compressive strength than those with rectangular and gyroid fills. Compared with specimens with a solid fill, specimens with a triangular fill can also provide more compressive strength in a unit mass. According to the results of standard specimens, following the requirement of strength and lightweight, 41% triangular fill is selected to manufacture the supporting part of a powered ankle-foot prosthesis. Under a compressive load of 1225 N, the strain of the assembly of the standard adaptor and the 3D-printed part is 1.32 ± 0.04%, which can meet the requirement of the design. This study can provide evidence for other 3D-printed applications with the requirement of compressive strength.

1 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
NANooranida Arifin
Nooranida Arifin
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
SASadeeq Ali
Sadeeq Ali
HGHossein Gholizadeh
Hossein Gholizadeh
WAWan Abu Bakar Wan Abas
Wan Abu Bakar Wan Abas
Purpose. This study aimed to evaluate the effects of prosthetic foot types on the postural stability among transtibial amputees when standing on different support surfaces.Materials and Methods. The postural stability of 10 transtibial amputees wearing solid ankle cushion heel (SACH) foot, single-axis (SA) foot, and energy-saving and return (ESAR) foot was assessed. Results were compared with able-bodied participants. Anterior-posterior stability index (APSI), mediolateral stability index (MLSI), and overall stability index (OSI) were measured by computed posturography in an upright stance on firm, foam, and unstable support surfaces.Results. The mean OSI score of SACH foot was significantly lower than that of an ESAR foot when the participants were standing on a compliant surface. When compared to able-bodied group, MLSI score was significantly higher for each of the prosthetic foot groups while OSI score was significantly higher for ESAR foot only in foam condition.Conclusions. Differences between prosthetic foot types and groups (amputees versus able-bodied) can only be distinguished when individuals were standing on a compliant surface. Amputees exhibited an increased postural instability in the mediolateral direction than able-bodied individuals. Hence, the restoration of stability in the frontal plane and the enhancement of proprioception at the residual limb should be the basis of rehabilitation programs.

1 January 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
NANooranida Arifin
Nooranida Arifin
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
SASadeeq Ali
Sadeeq Ali
WAWan Abu Bakar Wan Abas
Wan Abu Bakar Wan Abas
Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet. Ten male below-knee amputees were instructed to stand quietly on the Biodex® balance platform while wearing solid ankle cushion heel (SACH), single axis (SA) and energy storage and release (ESAR) prosthetic foot under different visual input conditions (eyes-opened and eyes-closed). The overall stability index (OSI), anterior- posterior stability index (APSI), and medial-lateral stability index (MLSI) were computed. Perceived balance assessment of each foot was evaluated using Activities-specific Balance Confidence (ABC) score. The findings highlights that SACH showed lowest overall stability index (indicating less body sway) during eyes-opened (OSI: SACH = 1.09, SA = 1.58, ESAR = 1.59) and SA showed lowest overall stability index during eyes-closed (OSI: SACH = 2.52, SA = 2.30, ESAR = 2.76) condition. However, overall stability indexes between foot types did not differ significantly during eyes-opened or eyes-closed (p = 0.651). There was a trend of instability which occurred more in medial-lateral compared to anterior-posterior direction for all foot types, with significant result in ESAR foot(eyes-opened: MLSI = 1.59, APSI = 0.65, p = 0.034; eyes-closed: MLSI = 2.76, APSI = 1.80, p = 0.017, respectively). When comparing between visual conditions, stability score was significantly higher during eyes-closed compared to eyes-opened situations for SACH and ESAR foot (eyes-closed vs opened; SACH OSI: 3.43 vs 1.71, p = 0.018 and MLSI: 3.43 vs 1.71, p = 0.018; ESAR OSI: 3.58 vs 1.86, p = 0.043 and APSI: 1.80 vs 0.65, p = 0.027). The results of this study suggested postural steadiness in below-knee amputees was not affected by the types of prosthetic foot during quiet upright standing, but was significantly affected when visual cues was absent.

28 January 2021 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
JLJingjing Liu
Jingjing Liu
NONoor Azuan Abu Osman
Noor Azuan Abu Osman
MKMouaz Al Kouzbary
Mouaz Al Kouzbary
HKHamza Al Kouzbary
Hamza Al Kouzbary
NRNasrul Anuar Abd Razak
Nasrul Anuar Abd Razak
NANooranida Arifin
Nooranida Arifin
A systematic review of the mechanical design of powered ankle–foot prostheses developed from 2000 to 2019 was conducted through database and manual searches. A total of ten English and two Chinese databases were searched using the same keywords. Moreover, information on commercialized prostheses was collected through a manual search. A total of 8729 publications were obtained from the database search, and 83 supplementary publications and 49 online product introductions were accumulated through the manual search. A total of 91 powered ankle–foot prostheses were extracted from 159 publications and online information after exclusion. The mechanical design characteristics of the prostheses were described briefly and compared after they were categorized into 11 subclassifications. This review revealed that a considerable number of powered ankle–foot prostheses were developed in the last 20 years. The development of such prostheses was characterized by alternative modes, that is, from pneumatic or hydraulic drivers to motorized drivers and from rigid transmissions to elastic actuators. This review contributes to the comprehensive understanding of current designs, which can benefit the combination of the advantages of and redundancy avoidance in future powered ankle–foot prostheses.