3D printing is the most suitable method to manufacture the frame parts of powered ankle-foot prostheses but the compressive strength of the 3D-printed part needs to be ensured. According to the compression test standard ASTM D695, the effect of infill pattern and density, which is transferred to the mass of the standard specimen, on the compressive strength is investigated with a carbon fiber-reinforced nylon material. With the same infill pattern, specimens with more mass have a higher compressive strength. With the same mass, specimens with triangular fill have a higher compressive strength than those with rectangular and gyroid fills. Compared with specimens with a solid fill, specimens with a triangular fill can also provide more compressive strength in a unit mass. According to the results of standard specimens, following the requirement of strength and lightweight, 41% triangular fill is selected to manufacture the supporting part of a powered ankle-foot prosthesis. Under a compressive load of 1225 N, the strain of the assembly of the standard adaptor and the 3D-printed part is 1.32 ± 0.04%, which can meet the requirement of the design. This study can provide evidence for other 3D-printed applications with the requirement of compressive strength.
Since humidity sensors have been widely used in many sectors, a suitable humidity sensing material with improved sensitivity, faster response and recovery times, better stability and low hysteresis is necessary to be developed. Here, we fabricate a uniformly porous humidity sensor using Ca, Ti substituted Mg ferrites with chemical formula of CaMgFe1.33Ti3O12 as humidity sensing materials by solid-sate step-sintering technique. This synthesis technique is useful to control the grain size with increased porosity to enhance the hydrophilic characteristics of the CaMgFe1.33Ti3O12 nanoceramic based sintered electro-ceramic nanocomposites. The highest porosity, lowest density and excellent surface-hydrophilicity properties were obtained at 1050 °C sintered ceramic. The performance of this impedance type humidity sensor was evaluated by electrical characterizations using alternating current (AC) in the 33%–95% relative humidity (RH) range at 25 °C. Compared with existing conventional resistive humidity sensors, the present sintered electro-ceramic nanocomposite based humidity sensor showed faster response time (20 s) and recovery time (40 s). This newly developed sensor showed extremely high sensitivity (%S) and small hysteresis of <3.4%. Long-term stability of the sensor had been determined by testing for 30 consecutive days. Therefore, the high performance sensing behavior of the present electro-ceramic nanocomposites would be suitable for a potential use in advanced humidity sensors.
8 June 2016 in IEEE/ASME Transactions on Mechatronics
This paper presents the design and evaluation of an in-socket sensory system for a transfemoral prosthetic leg using a set of piezoelectric sensors. The design process includes identifying the optimal mounting configuration of the sensors and determining their best placement. Two experiments were performed separately to address each objective. Results of the experiment suggested that cushionall with fit size cantilever with elastic foundation should be adopted to mount the sensors on the socket's wall. As for the placement of the sensors, the result suggested that the sensors should be positioned in zig-zag orientation from top to bottom, which can cover all of the most active area on the quadriceps and hamstring muscle groups. With the identified design, the socket was fabricated and instrumented for a transfemoral amputee and the performance of the in-socket sensory system was evaluated. The amputee performed level walking at normal speed on a 5-m straight pathway multiple times while the output voltage signal from each sensor was recorded. The output signals consistency was assessed by calculating the cross correlation, r, within five trials. In order to measure the strength of the correlation matrix of each sensor, the Frobenius norm, ||A|| F was calculated. The high norm value for all sensors pattern (||A|| F >4.5) for quadriceps implies that the mounting and placement of the sensors is most suitable for a consistent and reliable signal. For Hamstring, results inferred that except for the two sensors located on the top most position and the most bottom sensor, the other sensors showed good performance (||A|| F >4.4). Thus, the proposed design of the in-socket sensory system using piezo sensors was proven to be effective for a transfemoral prosthetic leg.
Armalcolite, a rare ceramic mineral and normally found in the lunar earth, was synthesized by solid-state step-sintering. The in situ phase-changed novel ceramic nanocrystals of Ca-Mg-Ti-Fe based oxide (CMTFOx), their chemical reactions and bonding with polydimethylsiloxane (PDMS) were determined by X-ray diffraction, infrared spectroscopy, and microscopy. Water absorption of all the CMTFOx was high. The lower dielectric loss tangent value (0.155 at 1 MHz) was obtained for the ceramic sintered at 1050 °C (S1050) and it became lowest for the S1050/PDMS nanocomposite (0.002 at 1 MHz) film, which was made by spin coating at 3000 rpm. The excellent flexibility (static modulus ≈ 0.27 MPa and elongation > 90%), viscoelastic property (tanδ = E″/E′: 0.225) and glass transition temperature (Tg: −58.5 °C) were obtained for S1050/PDMS film. Parallel-plate capacitive and flexible resistive humidity sensors have been developed successfully. The best sensing performance of the present S1050 (3000%) and its flexible S1050/PDMS composite film (306%) based humidity sensors was found to be at 100 Hz, better than conventional materials.
A systematic review of the mechanical design of powered ankle–foot prostheses developed from 2000 to 2019 was conducted through database and manual searches. A total of ten English and two Chinese databases were searched using the same keywords. Moreover, information on commercialized prostheses was collected through a manual search. A total of 8729 publications were obtained from the database search, and 83 supplementary publications and 49 online product introductions were accumulated through the manual search. A total of 91 powered ankle–foot prostheses were extracted from 159 publications and online information after exclusion. The mechanical design characteristics of the prostheses were described briefly and compared after they were categorized into 11 subclassifications. This review revealed that a considerable number of powered ankle–foot prostheses were developed in the last 20 years. The development of such prostheses was characterized by alternative modes, that is, from pneumatic or hydraulic drivers to motorized drivers and from rigid transmissions to elastic actuators. This review contributes to the comprehensive understanding of current designs, which can benefit the combination of the advantages of and redundancy avoidance in future powered ankle–foot prostheses.
17 January 2022 in International Journal of Control, Automation, and Systems