Huseyin Korkmaz

Dr. Huseyin Korkmaz

Department of Intelligent Transportation Systems, Istanbul University, Istanbul, İstanbul, Turkey (Türkiye)
orcid
Intelligent Transportation Systems

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Journal of Public Transportation
Verified
Journal Article
Closed access
PDF file
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
AFAkif Fidanoglu
Akif Fidanoglu
SOSalih Ozcelik
Salih Ozcelik
AOAbdullah Okumus
Abdullah Okumus
The purpose of this study is to investigate the factors affecting the acceptance and use of the APTS by its potential users. To achieve this, an integrated and expanded user acceptance model is introduced to explain the factors affecting the Behavioral Intention to use the APTS. A total of 316 surveys were conducted, from 275 participants by online surveys and 41 participants by face to face interviews. With the data that are acquired from Public Transportation (PT) users in Istanbul, the Unified Theory of Acceptance and Use of Technology 2 (UTAUT2) Model is modified and Performance Expectancy, Effort Expectancy, Social Influence, Facilitating Conditions, Hedonic Motivation, Price Value, Habit, Trust and Safety, Perceived Usefulness, Perceived Risk and Behavioral Intention constructs are utilized in the model. Age, gender and frequency of PT usage are included in the model to examine the moderating effect on the constructs while the model is tested with Structural Equation Modeling (SEM). The proposed model explains the 72 % of variances in this study which proves that the model has stronger predictive power compared with the previous Technology Acceptance Model (TAM) and UTAUT models. Performance Expectancy, Social Influence, Habit, and Trust and Safety constructs are concluded to have significant positive effects on Behavioral Intention. Public usage and acceptance are necessary for the complete utilization of APTS. The findings of these studies are hoped to guide the decision-makers of the PT industry to understand the factors affecting the use and acceptance of APTS and take the actions accordingly.

11 April 2023 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
UHUgur Cem Hasar
Ugur Cem Hasar
OROmar Mustafa Ramahi
Omar Mustafa Ramahi

9 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
UHUgur Cem Hasar
Ugur Cem Hasar
NENECİP ALTAY EREN
NECİP ALTAY EREN
HOHamdullah Ozturk
Hamdullah Ozturk
MIMucahit Izginli
Mucahit Izginli
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
Mohammad IrshidatMohammad Irshidat
Mohammad Irshidat
Mechanical and electromagnetic properties (over 2–16 GHz) of self-compacted geopolymer concrete (SCGC) samples with different amounts of nanosilica (NS) and steel-fiber (SF) have been examined. From the mechanical tests, it is observed that, while the amount of NS added to SCGC samples does not make any noticeable change in compressive strength and modulus of elasticity values, an increase in the amount and/or aspect ratio of SF additives improves these values. From the electromagnetic tests, it is noted that the effect of SF on the reflection properties of SCGC samples is relatively smaller than the effect of NS. Besides, while the incorporation of NS improves the resonance characteristics of transmission properties, additives of SF decrease these properties over the entire frequency band. Finally, sample C7, which has 1% SF with a smaller diameter and 2% NS in reference to the mass of the binder, has the optimum NS and SF additives, producing maximum absorbance values.

8 May 2023 in Safety Science
Verified
Journal Article
Closed access
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
EFEzgi Filazoglu
Ezgi Filazoglu
SASavas Selahattin Ates
Savas Selahattin Ates

24 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HHHafize Hasar
Hafize Hasar
UHUgur Cem Hasar
Ugur Cem Hasar
YKYunus Kaya
Yunus Kaya
HOHamdullah Ozturk
Hamdullah Ozturk
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
Omar RamahiOmar Ramahi
Omar Ramahi
Honey is a rich source of sugar and is one of the indispensable ingredients in infant foods. Thus, it can be subjected to adulteration due to its cost. Measurement techniques such as liquid chromatography and near-infrared spectroscopy, used for detecting any adulteration, are expensive and need to be conducted by highly trained personnel for off-line analysis. Microwave measurements, as a fast, simple, and relatively inexpensive analysis, have recently shown great potential in detecting adulteration within honey samples. Nonetheless, sensor types used in such measurements are conventional. In this study, a reflection-type sensitive microwave sensor terminated by a metal back is proposed for the first time in the literature for detection and quantification of water percentage (δ) level (mass-to-mass basis) within water-adulterated honey samples. When compared with other resonance-based microwave cavity sensors, thanks to its eight strips located at the centers of two closed circular loops, it demonstrates superior frequency selectivity and sensitivity (S = 5.13%) validated by full-wave 3D simulations performed by the CST Microwave Studio and equivalent circuit analysis carried out by the ADS software. For example, for ethanol, the proposed sensor gives a frequency shift of more than 1 GHz in the X-band. Resonance frequency shift and variation of the reflection coefficient amplitude (|S11|) are measured at X-band to detect honey samples with up to 8% adulteration level. Three different honey samples (flower honey, highland honey, and thyme honey) were examined to test the performance and applicability of the proposed sensor.

17 April 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
UHUgur Cem Hasar
Ugur Cem Hasar
HHHafize Hasar
Hafize Hasar
HOHamdullah Ozturk
Hamdullah Ozturk
Huseyin KorkmazHuseyin Korkmaz
Huseyin Korkmaz
YKYunus Kaya
Yunus Kaya
OROmar M. Ramahi
Omar M. Ramahi
A simple and inexpensive microwave measurement setup based on measurements of magnitudes of transmission properties ( $$|S_{21}|_{\text {dB}}$$ | S 21 | dB ) is proposed for industrial-based microwave aquametry (moisture or water content) applications. An easy-to-apply calibration procedure based on normalization is implemented to eliminate systematic errors in the measurement system. As a case study, we applied this setup for the quantification of water-adulteration in flower honey. After validating this system by distilled water and pure flower honey measurements, $$|S_{21}|_{\text {dB}}$$ | S 21 | dB measurements of the pure flower honey with various adulteration percentages ( $$\delta$$ δ ) up to 9% are conducted to examine the performance of the measurement setup for quantification of water adulteration. A multi-dimensional fitting procedure is implemented to predict $$\delta$$ δ using the proposed inexpensive microwave measurement setup. It is shown that it is possible to quantify an adulteration level with an accuracy better than $${\mp } 1$$ ∓ 1 % by the proposed measurement setup and the applied multi-dimensional fitting procedure.