Guopeng He

Mr. Guopeng He

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2024 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
STSongqin Tang
Songqin Tang
GHGuopeng He
Guopeng He
ZGZheng Gong
Zheng Gong
GLGuangqing Lin
Guangqing Lin
JLJiayu Liu
Jiayu Liu
This paper introduces fractional-order capacitors and fractional-order inductors into the conventional integer-order cascaded H-bridge multilevel static compensator (ICHM-STATCOM), thereby constructing the main circuit of the fractional-order cascaded H-bridge multilevel static compensator (FCHM-STATCOM). Mechanism-based modeling is employed to establish switching function models and low-frequency dynamic models for the FCHM-STATCOM in the three-phase stationary coordinate system (a-b-c). Subsequently, fractional-order rotating coordinate transformation is introduced to establish the mathematical model of the FCHM-STATCOM in the synchronous rotating coordinate system (d-q). Additionally, a fractional-order proportional-integral (FOPI)-based fractional-order dual closed-loop current decoupling control strategy is proposed. Finally, this paper validates the correctness of the established mathematical models through digital simulation. Moreover, the simulation results demonstrate that by appropriately selecting the order of fractional-order capacitors and fractional-order inductors, the FCHM-STATCOM exhibits superior dynamic and static characteristics compared to the conventional ICHM-STATCOM, and the FCHM-STATCOM provides a more flexible reactive power compensation solution for power systems.

16 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
WLWeixun Liu
Weixun Liu
GHGuopeng He
Guopeng He
The DC distribution network is a low-inertia system, which is very sensitive to load disturbance, system failure, and other factors. By adding virtual capacitance to the converter connected to the power supply, the virtual inertia of the DC power grid can be improved. Firstly, this paper proposes a strategy for adjusting virtual capacitance based on the voltage change rate to achieve adaptive control of virtual inertia, which enables the converter to quickly absorb or release energy during power fluctuations. Secondly, the adaptivity of the strategy is improved and the main control parameters in the proposed control method are qualitatively analyzed. Finally, the four-terminal photovoltaic storage DC distribution network system is constructed. Through Simulink, the adaptive virtual inertia control is incorporated on the battery side to simulate and validate the effectiveness of the strategy and the rationality of parameter analysis. The results show that this method can provide flexible and adjustable inertia support for DC grids and improve the voltage stability of DC grids.

5 January 2024 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
EZErmeng Zeng
Ermeng Zeng
XLXiaocong Li
Xiaocong Li
GHGuopeng He
Guopeng He
WLWeixun Liu
Weixun Liu
MXMeng Xuanren
Meng Xuanren
The fractional-order LCL filter, composed of two fractional-order inductors and one fractional-order capacitor, is a novel fractional-order π-type circuit introduced in recent years. Based on mathematical modeling, this article comprehensively studies the principles and frequency characteristics of fractional-order LCL filters. Five critical properties are derived and rigorously demonstrated. One of the most significant findings is that we identify the necessary and sufficient condition for resonance in fractional-order LCL filters when the sum of the orders of the fractional-order inductors and the fractional-order capacitor is equal to 2, which provides a theoretical foundation for effectively avoiding resonance in fractional-order LCL filters. The correctness of our theoretical derivation and analysis was confirmed through digital simulations. This study reveals that fractional-order LCL filters exhibit more versatile operational characteristics than traditional integer-order LCL filters, paving the way for broader application prospects.

1 August 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
JXJunhua Xu
Junhua Xu
GHGuopeng He
Guopeng He
YLYong Liu
Yong Liu
STSongqin Tang
Songqin Tang
DXDaiyu Xie
Daiyu Xie
MCMingyuan Chen
Mingyuan Chen
The weak AC grid in a modular multilevel converter modular multilevel converter based high voltage direct current (MMC‐HVDC) receiving‐end system requires faster reactive power support from the receiving‐end MMC. However, under the MMC traditional constant AC voltage dual‐loop control strategy, the increase in MMC's reactive power support speed will reduce the system stability. The reactive power cascade control strategy is a novel MMC control strategy. The analysis in this paper demonstrates that it possesses advanced performance under faster reactive power support, which is required by the MMC connected to a weak AC grid, but, some of its control links and operations can cause impacts exceeding that a weak AC grid can undertake. To solve this problem, based on the original control strategy, this paper proposes an improved reactive power cascade control strategy for weak AC grid conditions. The complete framework and the detailed design of primary control links of the improved cascade control strategy are displayed in this paper. Finally, a digital simulation has been conducted to validate the analysis and the proposed improved control strategy in this paper.

7 January 2025 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
GHGuopeng He
Guopeng He
STSongqin Tang
Songqin Tang
ZGZheng Gong
Zheng Gong
CWChunwei Wang
Chunwei Wang
YLYue Lan
Yue Lan
Recent research on fractional-order cascaded H-bridge multilevel static compensator (FCHM-STATCOM) indicates that it has better performance than the traditional cascaded H-bridge multilevel static compensator (CHM-STATCOM). The existing FCHM-STATCOM control system lacks some special control links for dealing with unbalanced operative situations, which is demanded by power systems. This paper improves the existing FCHM-STATCOM control system to satisfy the demand for power systems, creating the potential for it to be applied in the electrical industry. The improvement of the FCHM-STATCOM control system is based on traditional CHM-STATCOM control systems, introducing special control loops for unbalanced operative situations. The improved FCHM-STATCOM control system constructed in this paper consists of an outer control loop that can apply special strategies for different control objectives, two inner control loops, respectively, for positive- and negative-sequence currents, and an inter-phase balancing control loop for balancing its arm operation. At the end of this paper, the results of digital simulations verify the FCHM-STATCOM complete control system’s capacity to regulate its negative-sequence currents and balance its arm operation to deal with unbalanced operative situations. Moreover, based on different strategies, the control system shows effectiveness in eliminating power oscillations and current balancing.