Songqin Tang

Dr. Songqin Tang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2024 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
STSongqin Tang
Songqin Tang
GHGuopeng He
Guopeng He
ZGZheng Gong
Zheng Gong
GLGuangqing Lin
Guangqing Lin
JLJiayu Liu
Jiayu Liu
This paper introduces fractional-order capacitors and fractional-order inductors into the conventional integer-order cascaded H-bridge multilevel static compensator (ICHM-STATCOM), thereby constructing the main circuit of the fractional-order cascaded H-bridge multilevel static compensator (FCHM-STATCOM). Mechanism-based modeling is employed to establish switching function models and low-frequency dynamic models for the FCHM-STATCOM in the three-phase stationary coordinate system (a-b-c). Subsequently, fractional-order rotating coordinate transformation is introduced to establish the mathematical model of the FCHM-STATCOM in the synchronous rotating coordinate system (d-q). Additionally, a fractional-order proportional-integral (FOPI)-based fractional-order dual closed-loop current decoupling control strategy is proposed. Finally, this paper validates the correctness of the established mathematical models through digital simulation. Moreover, the simulation results demonstrate that by appropriately selecting the order of fractional-order capacitors and fractional-order inductors, the FCHM-STATCOM exhibits superior dynamic and static characteristics compared to the conventional ICHM-STATCOM, and the FCHM-STATCOM provides a more flexible reactive power compensation solution for power systems.

7 January 2025 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
GHGuopeng He
Guopeng He
STSongqin Tang
Songqin Tang
ZGZheng Gong
Zheng Gong
CWChunwei Wang
Chunwei Wang
YLYue Lan
Yue Lan
Recent research on fractional-order cascaded H-bridge multilevel static compensator (FCHM-STATCOM) indicates that it has better performance than the traditional cascaded H-bridge multilevel static compensator (CHM-STATCOM). The existing FCHM-STATCOM control system lacks some special control links for dealing with unbalanced operative situations, which is demanded by power systems. This paper improves the existing FCHM-STATCOM control system to satisfy the demand for power systems, creating the potential for it to be applied in the electrical industry. The improvement of the FCHM-STATCOM control system is based on traditional CHM-STATCOM control systems, introducing special control loops for unbalanced operative situations. The improved FCHM-STATCOM control system constructed in this paper consists of an outer control loop that can apply special strategies for different control objectives, two inner control loops, respectively, for positive- and negative-sequence currents, and an inter-phase balancing control loop for balancing its arm operation. At the end of this paper, the results of digital simulations verify the FCHM-STATCOM complete control system’s capacity to regulate its negative-sequence currents and balance its arm operation to deal with unbalanced operative situations. Moreover, based on different strategies, the control system shows effectiveness in eliminating power oscillations and current balancing.

12 April 2025 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
俊徐俊华 徐
俊华 徐
ZGZheng Gong
Zheng Gong
XLXiaocong Li
Xiaocong Li
STSongqin Tang
Songqin Tang
CWChunwei Wang
Chunwei Wang
YLYue Lan
Yue Lan
This paper investigates the fractional-order characteristics of the stator and rotor windings of a synchronous generator. Utilizing mechanism-based modeling methodology, it pioneers the derivation of the fractional-order voltage equations for a synchronous generator across both the three-phase stationary coordinate system (A, B, C) and the synchronous rotating coordinate system (d, q, 0). Through simplifying assumptions and rigorous derivations, a 2 + α (α ∈ (0, 2)) order synchronous generator model is formulated. This paper develops a digital simulation model of a fractional-order single-machine infinite bus system and analyzes the impact of the order α on the synchronous generator system’s dynamic performance through disturbance simulation experiments. Experimental results demonstrate that under conventional disturbances, increasing α from 0.8 to 1.2 reduces the system oscillation period and frequency while enhancing mechanical oscillation suppression, whereas decreasing α to 0.8 accelerates the generator terminal voltage response, lowers electromagnetic power overshoot, and improves excitation control effectiveness.