Calin Vasile Arcas

Dr. Calin Vasile Arcas

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
ASAdriana Saceleanu
Adriana Saceleanu
CACalin Vasile Arcas
Calin Vasile Arcas
NFNicu Fratila
Nicu Fratila
EKEarar Kamel
Earar Kamel
Background/Objectives: Intraoral scanning, a fast-evolving technology, is increasingly integrated into actual dental workflows due to its numerous advantages. Despite its growing adoption, challenges related to the accuracy of digital impressions remain. The existing literature identifies most of the factors influencing intraoral scanning accuracy (defined by precision and trueness), but it is fragmented and lacks a unified synthesis. In response to this gap, the present study aims to consolidate and structure the current evidence on the determinant factors and, based on these findings, to develop a clinically applicable procedural guideline for dental practitioners. Methods: A comprehensive literature review identified 43 distinct factors influencing intraoral scanning. Results: These factors encompass variables such as software versions and updates, implant characteristics (e.g., position, angulation, scan body design), materials, environmental conditions (e.g., lighting), and procedural elements including scanning strategy, pattern, aids, and operator experience. Subsequently, these identified factors were systematically classified into five distinct groups based on inherent similarities and relevance within the scanning workflow: IOS—characteristics and maintenance, intraoral morphology, materials, ambient conditions, and scanning strategy. To translate these findings into a practical framework, a four-step protocol was developed, designed for straightforward application by researchers and clinicians. Conclusions: This protocol—comprising: (1) Maintenance, (2) Evaluation, (3) Establishment and Execution of Scanning Strategy, and (4) Verification—aims to guide users effectively through the intraoral scanning process, mitigate common clinical challenges, and ensure broad applicability across diverse scanner systems, irrespective of the manufacturer or model.

24 May 2024 in Medicina
Verified
Journal Article
Open access
PDF file
CACalin Vasile Arcas
Calin Vasile Arcas
Ioan Andrei TigIoan Andrei Tig
Ioan Andrei Tig
DMDoru Florian-Cornel Moga
Doru Florian-Cornel Moga
Alexandra Lavinia VladAlexandra Lavinia Vlad
Alexandra Lavinia Vlad
CRCorina Roman-Filip
Corina Roman-Filip
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
Background and Objectives: Multiple sclerosis (MS) is a chronic neurodegenerative disease often linked with systemic conditions such as periodontal diseases (PDs). This systematic review aims to explore the association between inflammatory markers in saliva and PDs in MS patients, assessing the use of saliva as a non-invasive tool to monitor disease progression. Materials and Methods: 82 publications were examined after a thorough search of scholarly databases to determine whether inflammatory markers were present in MS patients and whether they were associated with periodontal disease (PD). Quality and bias were assessed using the Newcastle–Ottawa Scale, resulting in eight articles that were thoroughly analyzed. Results: The results point to a strong correlation between MS and periodontal disorders, which may point to the same pathophysiological mechanism. It does, however, underscore the necessity of additional study to determine a definitive causal association. Conclusions: The findings indicate a strong association between MS and PDs, likely mediated by systemic inflammatory responses detectable in saliva. The review highlights the importance of oral health in managing MS and supports the utility of saliva as a practical, non-invasive medium for monitoring systemic inflammation. Further research is necessary to confirm the causal relationships and to consider integrating salivary diagnostics into routine clinical management for MS patients.

Verified
Journal Article
Open access
PDF file
CACalin Vasile Arcas
Calin Vasile Arcas
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
DMDoru Florian-Cornel Moga
Doru Florian-Cornel Moga
IRIulian Roman-Filip
Iulian Roman-Filip
CACristina Ana-Maria Arcas
Cristina Ana-Maria Arcas
Mihai SavaMihai Sava
Mihai Sava
Background: MicroRNA-150 (miR-150) plays a critical role in immune regulation and has been implicated in autoimmune diseases like Multiple Sclerosis (MS). This review aims to evaluate miR-150’s potential as a biomarker for MS, necessitating this review to consolidate current evidence and highlight miR-150’s utility in improving diagnostic accuracy and monitoring disease progression. Methods: A comprehensive literature search was conducted in databases like PubMed, Scopus, Google Scholar, SciSpace, MDPI and Web of Science, adhering to PRISMA guidelines. Studies focusing on miR-150 implications in MS were included. Data extraction was conducted, while quality assessment was done using the NOS and AMSTAR 2 tools. With the extracted data a statistical analyses conducted. Results: 10 eligible articles were included in review. Findings show that miR-150 levels were consistently deregulated in MS patients compared to healthy controls, correlating with disease severity and clinical parameters such as (EDSS) scores and disease activity. Additionally, miR-150 is implicated in the inflammatory pathogenesis of MS, affecting immune cell regulation and inflammatory pathways. Conclusions: MiR-150 is a promising biomarker for MS, showing significant potential for improving diagnostic accuracy and monitoring disease progression. Its consistent deregulation in MS patients and correlation with clinical parameters underscore its clinical utility. Further research should validate miR-150’s salivary presence and its possible usage as a novel biomarker and therapeutic potential in the development of MS.

5 December 2024 in Reports
Verified
Journal Article
Open access
PDF file
TȚTeodora Țene
Teodora Țene
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
CACalin Vasile Arcas
Calin Vasile Arcas
Mihai SavaMihai Sava
Mihai Sava
CRCorina Roman-Filip
Corina Roman-Filip
This study evaluates the effectiveness of diode laser therapy, specifically the Biolase Epic X at 940 nm and 0.8–1 W, in conjunction with scaling and root planing (SRP) for treating generalized periodontitis. Background and Clinical Significance: A 32-year-old man underwent full-mouth disinfection and laser-assisted periodontal therapy, with follow-up at six months. Case Presentation: Significant improvements were observed, including reductions in bleeding on probing from 20% to 5%, in mean probing depth from 2.3 mm to 2.1 mm, and in clinical attachment level from −2.8 mm to −2.2 mm. Radiographic analysis showed a stabilization of bone loss and an 80% improvement in pathological sites. Conclusions: These findings indicate that diode laser therapy is an effective adjunct to SRP, enhancing periodontal health outcomes with minimal post-operative complications.

Verified
Journal Article
Open access
PDF file
CACalin Vasile Arcas
Calin Vasile Arcas
Ioan Andrei TigIoan Andrei Tig
Ioan Andrei Tig
DMDoru Florian-Cornel Moga
Doru Florian-Cornel Moga
Alexandra Lavinia VladAlexandra Lavinia Vlad
Alexandra Lavinia Vlad
ASAdriana Saceleanu
Adriana Saceleanu
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
Background: This study aimed to investigate the relationship between the Curve of Spee (COS) depth and malocclusion characteristics in a population from Sibiu County, Romania. The research sought to understand how the COS’s anatomical dimensions correlate with different classes of malocclusion and the position of the frontal teeth. Methods: A total of 265 participants from the Dentistry Ambulatory of the Military Hospital of Sibiu were included in this study. It employed digital intraoral scanning technology to measure the COS, overjet, and overbite, with malocclusion classification. Statistical analyses, including correlation and regression, were conducted to examine the relationships between COS depth, frontal teeth position, and malocclusion characteristics. Results: The average COS depth measured was 1.0564 mm, presenting variability when compared to existing literature. Most of the study participants had Class I malocclusion. A significant positive correlation between COS depth and overjet was identified, with no notable gender-based differences in these occlusal parameters. Conclusions: The findings affirm the integral role of COS in occlusal dynamics and malocclusion diagnosis. The COS measurement of a mean of 1.0564 mm, when compared to other results emphasizes the differences in occlusal curvature among various populations. The results contribute to a refined understanding of occlusal relationships, supporting the need for personalized orthodontic and prosthetic treatments based on precise anatomical measurements.

14 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAdriana Saceleanu
Adriana Saceleanu
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
CACalin Vasile Arcas
Calin Vasile Arcas
CACristina Ana-Maria Arcas
Cristina Ana-Maria Arcas
DDDragoș Dădârlat
Dragoș Dădârlat
LSLaura Stef
Laura Stef
Background: Composite restorations are the standard of care for posterior teeth due to their aesthetic properties and conservative nature. However, the choice between direct and semi-direct techniques can influence clinical longevity and performance. Objectives: This study aimed to compare the clinical performance of two restorative approaches: a direct technique and the semi-direct onlay technique in terms of aesthetic quality, surface finish, wear resistance, marginal integrity, and overall clinical efficiency over a two-year period. Methods: A total of 348 composite restorations were placed in 192 patients. Each restoration was evaluated at four timepoints: baseline (T0), 6 months (T1), 1 year (T2), and 2 years (T3). Clinical performance was assessed using standardised 5-point rating scales across the five dimensions. Repeated-measures ANOVA assessed changes over time, while Wilcoxon signed-rank and Mann–Whitney U tests were used for intra- and inter-group comparisons. Results: Significant time effects were observed across all clinical parameters (p < 0.0001). The direct technique exhibited superior initial results in aesthetics and surface finish at T0 and T1 (p < 0.001), but differences diminished by T3. In contrast, the semi-direct technique demonstrated improved performance in wear resistance and marginal integrity at T2 and T3. Both techniques showed progressive deterioration, particularly in marginal adaptation. Conclusions: The direct technique offers enhanced short-term aesthetics and procedural efficiency, while the semi-direct approach provides superior long-term durability and marginal adaptation.