Adriana Saceleanu

Mrs. Adriana Saceleanu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DGDaniela Gheorghita
Daniela Gheorghita
ARAlina Robu
Alina Robu
AAAntoniac Aurora
Antoniac Aurora
Antoniac IulianAntoniac Iulian
Antoniac Iulian
Lia-Mara DituLia-Mara Ditu
Lia-Mara Ditu
ASAdriana Saceleanu
Adriana Saceleanu
This study evaluates the antimicrobial and antioxidant activities of five essential oils (EO): pine oil, thyme oil, sage oil, fennel oil, and eucalyptus essential oils. To identify the chemical composition of the essential oils, we used gas chromatography coupled to a mass spectrometer (GC-MS). EO are predominantly characterized by the presence of monoterpene hydrocarbons and oxygenated monoterpenes, except in the case of fennel essential oil which contains phenylpropanoids as its main components. The antimicrobial activity of the EO was highlighted on four standard microbial strains (two Gram-negative strains-Escherichia coli ATCC 25922 and Pseudomonas aeruginosa ATCC 27853; one Gram-positive strain Staphylococcus aureus ATCC 25923, and one yeast strain-Candida albicans ATCC 10231). Antimicrobial activity was assessed by measuring the diameter of the inhibition zone, and by determining the values of the minimum inhibitory concentration (MIC) and minimum concentration of biofilm eradication (MCBE). Analyzing the diameter values of the inhibition zones we observed increased efficiency of thyme essential oil, which showed the highest values for all tested microbial species. The results of tests performed in a liquid confirm the high sensitivity of the standard strain Escherichia coli ATCC 25922 to the action of all essential oils, the lowest values of MIC being recorded for sage and thyme essential oils. For the most essential oils tested in this study, the MCBE values are close to the MIC values, except for the pine EO which seems to have stimulated the adhesion of the yeast strain at concentrations lower than 5%. The study highlights the antimicrobial activity of the tested essential oils on Gram-positive and Gram-negative strains.

Verified
Journal Article
Open access
PDF file
Anca Maria FratilaAnca Maria Fratila
Anca Maria Fratila
ASAdriana Saceleanu
Adriana Saceleanu
CACalin Vasile Arcas
Calin Vasile Arcas
NFNicu Fratila
Nicu Fratila
EKEarar Kamel
Earar Kamel
Background/Objectives: Intraoral scanning, a fast-evolving technology, is increasingly integrated into actual dental workflows due to its numerous advantages. Despite its growing adoption, challenges related to the accuracy of digital impressions remain. The existing literature identifies most of the factors influencing intraoral scanning accuracy (defined by precision and trueness), but it is fragmented and lacks a unified synthesis. In response to this gap, the present study aims to consolidate and structure the current evidence on the determinant factors and, based on these findings, to develop a clinically applicable procedural guideline for dental practitioners. Methods: A comprehensive literature review identified 43 distinct factors influencing intraoral scanning. Results: These factors encompass variables such as software versions and updates, implant characteristics (e.g., position, angulation, scan body design), materials, environmental conditions (e.g., lighting), and procedural elements including scanning strategy, pattern, aids, and operator experience. Subsequently, these identified factors were systematically classified into five distinct groups based on inherent similarities and relevance within the scanning workflow: IOS—characteristics and maintenance, intraoral morphology, materials, ambient conditions, and scanning strategy. To translate these findings into a practical framework, a four-step protocol was developed, designed for straightforward application by researchers and clinicians. Conclusions: This protocol—comprising: (1) Maintenance, (2) Evaluation, (3) Establishment and Execution of Scanning Strategy, and (4) Verification—aims to guide users effectively through the intraoral scanning process, mitigate common clinical challenges, and ensure broad applicability across diverse scanner systems, irrespective of the manufacturer or model.

12 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Pham Hong QuanPham Hong Quan
Pham Hong Quan
Antoniac IulianAntoniac Iulian
Antoniac Iulian
Florin MiculescuFlorin Miculescu
Florin Miculescu
AAAntoniac Aurora
Antoniac Aurora
Veronica Manescu (Paltanea)Veronica Manescu (Paltanea)
Veronica Manescu (Paltanea)
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
Fluoride conversion coatings on Mg present many advantages, among which one can find the reduction of the corrosion rate under “in vivo” or “in vitro” conditions and the promotion of the calcium phosphate deposition. Moreover, the fluoride ions released from MgF2 do not present cytotoxic effects and inhibit the biofilm formation, and thus these treated alloys are very suitable for cardiovascular stents and biodegradable orthopedic implants. In this paper, the biodegradation behavior of four new magnesium biodegradable alloys that have been developed in the laboratory conditions, before and after surface modifications by fluoride conversion (and sandblasting) coatings, are analyzed. We performed structural and surface analysis (XRD, SEM, contact angle) before and after applying different surface treatments. Furthermore, we studied the electrochemical behavior and biodegradation of all experimental samples after immersion test performed in NaCl solution. For a better evaluation, we also used LM and SEM for evaluation of the corroded samples after immersion test. The results showed an improved corrosion resistance for HF treated alloy in the NaCl solution. The chemical composition, uniformity, thickness and stability of the layers generated on the surface of the alloys significantly influence their corrosion behavior. Our study reveals that HF treatment is a beneficial way to improve the biofunctional properties required for the studied magnesium alloys to be used as biomaterials for manufacturing the orthopedic implants.

27 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
Iosif HULKAIosif HULKA
Iosif HULKA
NSNestor Ruben Florido Suarez
Nestor Ruben Florido Suarez
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
ASAdriana Saceleanu
Adriana Saceleanu
Ti and its alloys have the most satisfactory properties for biomedical applications due to their specific strength, high corrosion resistance, and high biocompatibility. Ti-6Al-7Nb has been approved for clinical use, proving to be a viable replacement for the Ti-6Al-4V alloy that has been used for many decades in medical applications. In our study, the Ti-6Al-7Nb alloy underwent heat treatment, was cooled in various cooling media such as mineral oil and water, and was then quenched in the oven. The microstructure was investigated, and the mechanical characterization was carried out by Vickers microhardness test. Young’s modulus measurements and tensile tests were performed in order to study the effect of cooling media on the material. To study the corrosion behavior, in vitro studies were performed on the Ti-6Al-7Nb samples in simulated body conditions by using artificial saliva. It was observed that the martensitic phase changed as a function of cooling media, and a less intensive cooling medium decreases strength properties’ indicators as well as hardness values. The results emphasize that the use of heat treatment improves the passive layer’s resistance in the presence of artificial saliva.

2 August 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Cosmin Mihai CotrutCosmin Mihai Cotrut
Cosmin Mihai Cotrut
UEUngureanu Elena
Ungureanu Elena
IIIonut Cornel Ionescu
Ionut Cornel Ionescu
RZRaluca Ioana Zamfir
Raluca Ioana Zamfir
AKAdrian Emil Kiss
Adrian Emil Kiss
ASAdriana Saceleanu
Adriana Saceleanu
The aim of this research was to obtain hydroxyapatite (HAp)-based coatings doped with different concentrations of Mg on a Ti nanostructured surface through electrochemical techniques and to evaluate the influence of Mg content on the properties of HAp. The undoped and doped HAp-based coatings were electrochemically deposited in galvanostatic pulsed mode on titania nanotubes with a diameter of ~72 nm, being designed to enhance the adhesion of the HAp coatings to the Ti substrate. The obtained materials were investigated by Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), X-Ray Diffraction (XRD), and Fourier-Transform Infra-Red spectroscopy (FTIR). The adhesion of the coatings to the substrate was also evaluated with the help of the “tape-test” and the micro-scratch test. The morphology (SEM) of all the coatings is made of very thin and narrow ribbon-like crystals, with some alterations with respect to the Mg amount in the coatings. Thus, a concentration of 1 mM of Mg in the electrolyte leads to wider and thicker ribbon-like crystals, while a concentration of 1.5 mM in the electrolyte generated a morphology that resembles the undoped HAp. Both phase composition (XRD) and chemical bonds (FTIR) analysis proved the formation of HAp in all coatings. Moreover, according to XRD, all coatings have a strong orientation toward the (002) plane. Irrespective of the Mg content, all coatings registered an average roughness between approx. 500 and 600 nm, while the coating thickness increased after addition of Mg, from a value of 9.6 μm, for the undoped HAp, to 11.3 μm and ~13.7 μm for H/Mg1 and H/Mg2, respectively. In terms of adhesion, it was shown that the coatings a H/Mg2 had a poorer adhesion when compared to H/Mg1 and the undoped HAp (H), which registered similar adhesion, indicating that a concentration of 1.5 mM of Mg in the electrolyte reduces the adhesion of the Hap-based coatings to the nanostructured surface. The obtained results indicated that Mg concentrations up to 1 mM in the electrolyte can enhance the properties of HAp-based coatings electrochemically deposited on a nanostructured surface, while even a slightly higher concentration of 1.5 mM can negatively impact the characteristics of HAp coatings.

26 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
Iosif HULKAIosif HULKA
Iosif HULKA
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
DBDragos Buzdugan
Dragos Buzdugan
ASAdriana Saceleanu
Adriana Saceleanu
In the present study, the microstructure and mechanical properties of Ti-xTa (x = 5%, 15%, and 25% wt. Ta) alloys produced by using an induced furnace by the cold crucible levitation fusion technique were investigated and compared. The microstructure was examined by scanning electron microscopy and X-ray diffraction. The alloys present a microstructure characterized by the α′ lamellar structure in a matrix of the transformed β phase. From the bulk materials, the samples for the tensile tests were prepared and based on the results and the elastic modulus was calculated by deducting the lowest values for the Ti-25Ta alloy. Moreover, a surface alkali treatment functionalization was performed using 10 M NaOH. The microstructure of the new developed films on the surface of the Ti-xTa alloys was investigated by scanning electron microscopy and the chemical analysis revealed the formation of sodium titanate and sodium tantanate along with titanium and tantalum oxides. Using low loads, the Vickers hardness test revealed increased hardness values for the alkali-treated samples. After exposure to simulated body fluid, phosphorus and calcium were identified on the surface of the new developed film, indicating the development of apatite. The corrosion resistance was evaluated by open cell potential measurements in simulated body fluid before and after NaOH treatment. The tests were performed at 22 °C as well as at 40 °C, simulating fever. The results show that the Ta content has a detrimental effect on the investigated alloys’ microstructure, hardness, elastic modulus, and corrosion behavior.