Developers and users of artificial-intelligence-based tools for automatic contouring and treatment planning in radiotherapy are expected to assess clinical acceptability of these tools. However, what is ‘clinical acceptability’? Quantitative and qualitative approaches have been used to assess this ill-defined concept, all of which have advantages and disadvantages or limitations. The approach chosen may depend on the goal of the study as well as on available resources. In this paper, we discuss various aspects of ‘clinical acceptability’ and how they can move us toward a standard for defining clinical acceptability of new autocontouring and planning tools.
10 February 2024 in Computerized Medical Imaging and Graphics
Background/Objectives: We assessed the influence of local patients and clinical characteristics on the performance of commercial deep learning (DL) segmentation models for head-and-neck (HN), breast, and prostate cancers. Methods: Clinical computed tomography (CT) scans and clinically approved contours of 210 patients (53 HN, 49 left breast, 55 right breast, and 53 prostate cancer) were used to train and validate segmentation models integrated within a vendor-supplied DL training toolkit and to assess the performance of both vendor-pretrained and custom-trained models. Four custom models (HN, left breast, right breast, and prostate) were trained and validated with 30 (training)/5 (validation) HN, 34/5 left breast, 39/5 right breast, and 30/5 prostate patients to auto-segment a total of 24 organs at risk (OARs). Subsequently, both vendor-pretrained and custom-trained models were tested on the remaining patients from each group. Auto-segmented contours were evaluated by comparing them with clinically approved contours via the Dice similarity coefficient (DSC) and mean surface distance (MSD). The performance of the left and right breast models was assessed jointly according to ipsilateral/contralateral locations. Results: The average DSCs for all structures in vendor-pretrained and custom-trained models were as follows: 0.81 ± 0.12 and 0.86 ± 0.11 in HN; 0.67 ± 0.16 and 0.80 ± 0.11 in the breast; and 0.87 ± 0.09 and 0.92 ± 0.06 in the prostate. The corresponding average MSDs were 0.81 ± 0.76 mm and 0.76 ± 0.56 mm (HN), 4.85 ± 2.44 mm and 2.42 ± 1.49 mm (breast), and 2.17 ± 1.39 mm and 1.21 ± 1.00 mm (prostate). Notably, custom-trained models showed significant improvements over vendor-pretrained models for 14 of 24 OARs, reflecting the influence of data/contouring variations in segmentation performance. Conclusions: These findings underscore the substantial impact of institutional preferences and clinical practices on the implementation of vendor-pretrained models. We also found that a relatively small amount of institutional data was sufficient to train customized segmentation models with sufficient accuracy.
Background/Objectives: Advancements in radiotherapy technology now enable the delivery of ablative doses to targets in the upper urinary tract, including primary renal cell carcinoma (RCC) or upper tract urothelial carcinomas (UTUC), and secondary involvement by other histologies. Magnetic resonance imaging-guided linear accelerators (MR-Linacs) have shown promise to further improve the precision and adaptability of stereotactic body radiotherapy (SBRT). Methods: This single-institution retrospective study analyzed 34 patients (31 with upper urinary tract non-metastatic primaries [RCC or UTUC] and 3 with metastases of non-genitourinary histology) who received SBRT from August 2020 through September 2024 using a 1.5 Tesla MR-Linac system. Treatment plans were adjusted by using [online settings] for “adapt-to-position” (ATP) and “adapt-to-shape” (ATS) strategies for anatomic changes that developed during treatment; compression belts were used for motion management. Results: The median duration of treatment was 56 min overall and was significantly shorter using the adapt-to-position (ATP) (median 54 min, range 38–97 min) in comparison with adapt-to-shape (ATS) option (median 80, range 53–235 min). Most patients (77%) experienced self-resolving grade 1–2 acute radiation-induced toxicity; none had grade ≥ 3. Three participants (9%) experienced late grade 1–2 toxicity, potentially attributable to SBRT, with one (3%) experiencing grade 3. Conclusions: We conclude that MR-Linac-based SBRT, supported by online plan adaptation, is a feasible, safe, and highly precise treatment modality for the definitive management of select upper urinary tract lesions.
In this study, we aimed to enhance the contouring accuracy of cardiac pacemakers by improving their visualization using deep learning models to predict MV CBCT images based on kV CT or CBCT images. Ten pacemakers and four thorax phantoms were included, creating a total of 35 combinations. Each combination was imaged on a Varian Halcyon (kV/MV CBCT images) and Siemens SOMATOM CT scanner (kV CT images). Two generative adversarial network (GAN)-based models, cycleGAN and conditional GAN (cGAN), were trained to generate synthetic MV (sMV) CBCT images from kV CT/CBCT images using twenty-eight datasets (80%). The pacemakers in the sMV CBCT images and original MV CBCT images were manually delineated and reviewed by three users. The Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and mean surface distance (MSD) were used to compare contour accuracy. Visual inspection showed the improved visualization of pacemakers on sMV CBCT images compared to original kV CT/CBCT images. Moreover, cGAN demonstrated superior performance in enhancing pacemaker visualization compared to cycleGAN. The mean DSC, HD95, and MSD for contours on sMV CBCT images generated from kV CT/CBCT images were 0.91 ± 0.02/0.92 ± 0.01, 1.38 ± 0.31 mm/1.18 ± 0.20 mm, and 0.42 ± 0.07 mm/0.36 ± 0.06 mm using the cGAN model. Deep learning-based methods, specifically cycleGAN and cGAN, can effectively enhance the visualization of pacemakers in thorax kV CT/CBCT images, therefore improving the contouring precision of these devices.
17 October 2025 in International Journal of Radiation Oncology, Biology, Physics