Shuangyi Wang

Dr. Shuangyi Wang

1. Institute of Automation, Chinese Academy of Sciences, Beijing, China
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Xianqiang BaoXianqiang Bao
Xianqiang Bao
Shuangyi WangShuangyi Wang
Shuangyi Wang
LZLingling Zheng
Lingling Zheng
James HousdenJames Housden
James Housden
JHJoseph V. Hajnal
Joseph V. Hajnal
Kawal RhodeKawal Rhode
Kawal Rhode
Medical ultrasound (US) is of increasing importance in medical diagnosis and intraoperative assistance and possesses great potential advantages when integrated with robotics. However, some concerns, including the operation efficiency, operation safety, image quality, and comfort of patients, remain after introducing robotics into medical ultrasound. In this article, an ultrasound robot integrating a force control mechanism, force/torque measurement mechanism, and online adjustment method is proposed to overcome the current limitations. The ultrasound robot can measure operating forces and torques, provide adjustable constant operating forces, eliminate great operating forces introduced by accidental operations, and achieve various scanning depths based on clinical requirements. The proposed ultrasound robot would potentially facilitate sonographers to find the targets quickly, improve operation safety and efficiency, and decrease patients’ discomfort. Simulations and experiments were carried out to evaluate the performance of the ultrasound robot. Experimental results show that the proposed ultrasound robot is able to detect operating force in the $z$ -direction and torques around the $x$ - and $y$ -directions with errors of 3.53%, 6.68%, and 6.11% F.S., maintain the constant operating force with errors of less than 0.57 N, and achieve various scanning depths for target searching and imaging. This proposed ultrasound robot has good performance and would potentially be used in medical ultrasound.

6 November 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
Shuangyi WangShuangyi Wang
Shuangyi Wang
KWKehao Wang
Kehao Wang
RTRuijie Tang
Ruijie Tang
JQJingzhe Qiao
Jingzhe Qiao
HLHongbin Liu
Hongbin Liu
ZHZeng-Guang Hou
Zeng-Guang Hou
Nasopharyngeal (NP) swab sampling is an effective approach for the diagnosis of coronavirus disease 2019 (COVID-19). Medical staffs carrying out the task of collecting NP specimens are in close contact with the suspected patient, thereby posing a high risk of cross-infection. We propose a low-cost miniature robot that can be easily assembled and remotely controlled. The system includes an active end-effector, a passive positioning arm, and a detachable swab gripper with integrated force sensing capability. The cost of the materials for building this robot is 55 USD and the total weight of the functional part is 0.23kg. The design of the force sensing swab gripper was justified using Finite Element (FE) modeling and the performances of the robot were validated with a simulation phantom and three pig noses. FE analysis indicated a 0.5mm magnitude displacement of the gripper’s sensing beam, which meets the ideal detecting range of the optoelectronic sensor. Studies on both the phantom and the pig nose demonstrated the successful operation of the robot during the collection task. The average forces were found to be 0.35N and 0.68N, respectively. It is concluded that the proposed robot is promising and could be further developed to be used in vivo.

4 December 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LLLukas Lindenroth
Lukas Lindenroth
RHRichard James Housden
Richard James Housden
Shuangyi WangShuangyi Wang
Shuangyi Wang
JBJunghwan Back
Junghwan Back
Kawal RhodeKawal Rhode
Kawal Rhode
HLHongbin Liu
Hongbin Liu
Objective: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. Methods: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. Results: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of $\mathbf {1.18\pm 0.29}$ mm in position and $\mathbf {0.92\pm 0.47^{\circ }}$ in orientation. The derived controller is, with an average position error of 0.39 mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. Conclusion: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. Significance: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks.

9 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shuangyi WangShuangyi Wang
Shuangyi Wang
James HousdenJames Housden
James Housden
YNYohan Noh
Yohan Noh
ASAnisha Singh
Anisha Singh
LLLukas Lindenroth
Lukas Lindenroth
Kawal RhodeKawal Rhode
Kawal Rhode
Robotic systems have great potential to assist ultrasound (US) examination. Currently, the safety management method to limit the force that a US robot can apply mostly relies on force sensing and software-based algorithms. This causes the concern that the potential failure of sensors, electrical systems, or software could lead to patient injuries. In this paper, we investigated a customized spring-loaded ball clutch joint designed for a newly developed US robot to passively limit the force applied. The working mechanism of the clutch was modelled and the kinematic-based analysis was performed to understand the variation of the limited force at different postures of the robot. The triggering torque of the clutch was found to be 3928 N·mm, which results in the mean limited force 22.10 ± 1.76 N at the US probe end based on potential postures. The real measurement of the implemented design indicated that the limited force could be set between 17 and 24 N at the neutral posture depending on the preload. With the maximum preload, the mean limited force was found to be 21.98 ± 0.96 N based on 30 repeated measurements. The practically measured results meet the expectation from the theoretical calculation, and the resulting small variation has indicated a good repeatability of the clutch. Based on this evidence, it is concluded that the proposed clutch meets the design aim that it can limit the force applied within a safe range while at the same time ensuring that the required force is applied at different postures.

1 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JHJames Housden
James Housden
Shuangyi WangShuangyi Wang
Shuangyi Wang
Xianqiang BaoXianqiang Bao
Xianqiang Bao
JZJia Zheng
Jia Zheng
ESEmily Skelton
Emily Skelton
Kawal RhodeKawal Rhode
Kawal Rhode
Standardized acquisitions and diagnoses using robots and AI would potentially increase the general usability and reliability of medical ultrasound. Working towards this prospect, this letter presents the recent developments of a standardized acquisition workflow using a novel dual-probe ultrasound robot, for a project known as intelligent Fetal Imaging and Diagnosis (iFIND). The workflow includes an abdominal surface mapping step to obtain a non-parametric spline surface, a rule-based end-point calculation method to position each individual joint, and a motor synchronization method to achieve a smooth motion towards a target point. The design and implementation of the robot are first presented in this letter and the proposed workflow is then explained in detail with simulation and volunteer experiments performed and analyzed. The closed-form analytical solution to the specific motion planning problem has demonstrated a reliable performance controlling the robot to move towards the expected scanning areas and the calculated proximity of the robot to the surface shows that the robot maintains a safe distance while moving around the abdomen. The volunteer study has successfully demonstrated the reliable working and controllability of the robot in terms of acquiring desired ultrasound views. Our future work will focus on improving the motion planning, and on integrating the proposed standardized acquisition workflow with newly-developed ultrasound image processing methods to obtain diagnostic results in an accurate and consistent way.

17 July 2019
Verified
Book Chapter
Closed access
PDF file
Shuangyi WangShuangyi Wang
Shuangyi Wang
JHJames Housden
James Housden
YNYohan Noh
Yohan Noh
DSDavinder Singh
Davinder Singh
ASAnisha Singh
Anisha Singh
KRKawal Rhode
Kawal Rhode