James Housden

Dr. James Housden


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Xianqiang BaoXianqiang Bao
Xianqiang Bao
Shuangyi WangShuangyi Wang
Shuangyi Wang
LZLingling Zheng
Lingling Zheng
James HousdenJames Housden
James Housden
JHJoseph V. Hajnal
Joseph V. Hajnal
Kawal RhodeKawal Rhode
Kawal Rhode
Medical ultrasound (US) is of increasing importance in medical diagnosis and intraoperative assistance and possesses great potential advantages when integrated with robotics. However, some concerns, including the operation efficiency, operation safety, image quality, and comfort of patients, remain after introducing robotics into medical ultrasound. In this article, an ultrasound robot integrating a force control mechanism, force/torque measurement mechanism, and online adjustment method is proposed to overcome the current limitations. The ultrasound robot can measure operating forces and torques, provide adjustable constant operating forces, eliminate great operating forces introduced by accidental operations, and achieve various scanning depths based on clinical requirements. The proposed ultrasound robot would potentially facilitate sonographers to find the targets quickly, improve operation safety and efficiency, and decrease patients’ discomfort. Simulations and experiments were carried out to evaluate the performance of the ultrasound robot. Experimental results show that the proposed ultrasound robot is able to detect operating force in the $z$ -direction and torques around the $x$ - and $y$ -directions with errors of 3.53%, 6.68%, and 6.11% F.S., maintain the constant operating force with errors of less than 0.57 N, and achieve various scanning depths for target searching and imaging. This proposed ultrasound robot has good performance and would potentially be used in medical ultrasound.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RKRashed Karim
Rashed Karim
James HousdenJames Housden
James Housden
MBMayuragoban Balasubramaniam
Mayuragoban Balasubramaniam
ZCZhong Chen
Zhong Chen
DPDaniel Perry
Daniel Perry
Kawal RhodeKawal Rhode
Kawal Rhode
Late Gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging can be used to visualise regions of fibrosis and scarring in the left atrium (LA) myocardium. This can be important for treatment stratification of patients with atrial fibrillation (AF) and for assessment of treatment after radio frequency catheter ablation (RFCA). In this paper we present a standardised evaluation benchmarking framework for algorithms segmenting fibrosis and scar from LGE CMR images. The algorithms reported are the response to an open challenge that was put to the medical imaging community through an ISBI (IEEE International Symposium on Biomedical Imaging) workshop.

17 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
YNYohan Noh
Yohan Noh
JBJoao Bimbo
Joao Bimbo
SSSina Sareh
Sina Sareh
HWHelge Wurdemann
Helge Wurdemann
JFJan Fraś
Jan Fraś
Kawal RhodeKawal Rhode
Kawal Rhode
This paper presents a multi-axis force/torque sensor based on simply-supported beam and optoelectronic technology. The sensor’s main advantages are: (1) Low power consumption; (2) low-level noise in comparison with conventional methods of force sensing (e.g., using strain gauges); (3) the ability to be embedded into different mechanical structures; (4) miniaturisation; (5) simple manufacture and customisation to fit a wide-range of robot systems; and (6) low-cost fabrication and assembly of sensor structure. For these reasons, the proposed multi-axis force/torque sensor can be used in a wide range of application areas including medical robotics, manufacturing, and areas involving human–robot interaction. This paper shows the application of our concept of a force/torque sensor to flexible continuum manipulators: A cylindrical MIS (Minimally Invasive Surgery) robot, and includes its design, fabrication, and evaluation tests.

11 June 2013 in Medical Physics
Verified
Journal Article
Open access
YMYingLiang Ma
YingLiang Ma
NGNicolas Gogin
Nicolas Gogin
PCPascal Cathier
Pascal Cathier
James HousdenJames Housden
James Housden
GGGeert Gijsbers
Geert Gijsbers
Kawal RhodeKawal Rhode
Kawal Rhode
Purpose:: X‐ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X‐ray images have poor soft tissue contrast and, for this reason, overlay of a three‐dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods:: In this paper, the authors present a novel unified computational framework for image‐based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape‐constrained searching and model‐based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real‐time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x‐ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real‐time.Results:: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two‐dimensional (2D) detection errors of 0.50 ± 0.29, 0.92 ± 0.61, and 0.63 ± 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 ± 0.28, 0.64 ± 0.37, and 0.53 ± 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions:: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real‐time. The accuracy of the proposed methods is sub‐mm and the methods are robust toward low‐dose x‐ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.

13 October 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YNYohan Noh
Yohan Noh
SSSina Sareh
Sina Sareh
HWHelge Wurdemann
Helge Wurdemann
HLHongbin Liu
Hongbin Liu
JBJunghwan Back
Junghwan Back
Kaspar AlthoeferKaspar Althoefer
Kaspar Althoefer
This paper proposes a force/torque sensor structure that can be easily integrated into a flexible manipulator structure. The sensor's ring-like structure with its hollow inner section provides ample space for auxiliary components, such as cables and tubes, to be passed through and, hence, is very suitable for integration with tendon-driven and fluid-actuated manipulators. The sensor structure can also accommodate the wiring for a distributed sensor system as well as for diagnostic instruments that may be incorporated in the manipulator. Employing a sensing approach based on optical fibers as done here allows for the creation of sensors that are free of electrical currents at the point of sensing and immune to magnetic fields. These sensors are inherently safe when used in the close vicinity of humans and their measuring performance is not impaired when they are operated in or nearby machines, such as magnetic resonance imaging scanners. This type of sensor concept is particularly suitable for inclusion in instruments and robotic tools for minimally invasive surgery. This paper summarizes the design, integration challenges, and calibration of the proposed optical three-axis force sensor. The experimental results confirm the effectiveness of our optical sensing approach and show that after calibrating its stiffness matrix, force and momentum components can be determined accurately.

30 September 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
XWXianliang Wu
Xianliang Wu
James HousdenJames Housden
James Housden
YMYingLiang Ma
YingLiang Ma
BRBenjamin Razavi
Benjamin Razavi
Kawal RhodeKawal Rhode
Kawal Rhode
DRDaniel Rueckert
Daniel Rueckert
Echocardiography is a potential alternative to X-ray fluoroscopy in cardiac catheterization given its richness in soft tissue information and its lack of ionizing radiation. However, its small field of view and acoustic artifacts make direct automatic segmentation of the catheters very challenging. In this study, a fast catheter segmentation framework for echocardiographic imaging guided by the segmentation of corresponding X-ray fluoroscopic imaging is proposed. The complete framework consists of: 1) catheter initialization in the first X-ray frame; 2) catheter tracking in the rest of the X-ray sequence; 3) fast registration of corresponding X-ray and ultrasound frames; and 4) catheter segmentation in ultrasound images guided by the results of both X-ray tracking and fast registration. The main contributions include: 1) a Kalman filter-based growing strategy with more clinical data evaluation; 2) a SURF detector applied in a constrained search space for catheter segmentation in ultrasound images; 3) a two layer hierarchical graph model to integrate and smooth catheter fragments into a complete catheter; and 4) the integration of these components into a system for clinical applications. This framework is evaluated on five sequences of porcine data and four sequences of patient data comprising more than 3000 X-ray frames and more than 1000 ultrasound frames. The results show that our algorithm is able to track the catheter in ultrasound images at 1.3 s per frame, with an error of less than 2 mm. However, although this may satisfy the accuracy for visualization purposes and is also fast, the algorithm still needs to be further accelerated for real-time clinical applications.