Xianqiang Bao

Dr. Xianqiang Bao

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Xianqiang BaoXianqiang Bao
Xianqiang Bao
Shuangyi WangShuangyi Wang
Shuangyi Wang
LZLingling Zheng
Lingling Zheng
James HousdenJames Housden
James Housden
JHJoseph V. Hajnal
Joseph V. Hajnal
Kawal RhodeKawal Rhode
Kawal Rhode
Medical ultrasound (US) is of increasing importance in medical diagnosis and intraoperative assistance and possesses great potential advantages when integrated with robotics. However, some concerns, including the operation efficiency, operation safety, image quality, and comfort of patients, remain after introducing robotics into medical ultrasound. In this article, an ultrasound robot integrating a force control mechanism, force/torque measurement mechanism, and online adjustment method is proposed to overcome the current limitations. The ultrasound robot can measure operating forces and torques, provide adjustable constant operating forces, eliminate great operating forces introduced by accidental operations, and achieve various scanning depths based on clinical requirements. The proposed ultrasound robot would potentially facilitate sonographers to find the targets quickly, improve operation safety and efficiency, and decrease patients’ discomfort. Simulations and experiments were carried out to evaluate the performance of the ultrasound robot. Experimental results show that the proposed ultrasound robot is able to detect operating force in the $z$ -direction and torques around the $x$ - and $y$ -directions with errors of 3.53%, 6.68%, and 6.11% F.S., maintain the constant operating force with errors of less than 0.57 N, and achieve various scanning depths for target searching and imaging. This proposed ultrasound robot has good performance and would potentially be used in medical ultrasound.

19 February 2018 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
Xianqiang BaoXianqiang Bao
Xianqiang Bao
SGShuoxin Gu
Shuoxin Gu
NXNan Xiao
Nan Xiao
YLYouxiang Li
Youxiang Li
CYCheng Yang
Cheng Yang
YJYuhua Jiang
Yuhua Jiang

7 April 2018 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
Xianqiang BaoXianqiang Bao
Xianqiang Bao
SGShuoxin Gu
Shuoxin Gu
NXNan Xiao
Nan Xiao
YLYouxiang Li
Youxiang Li
CYCheng Yang
Cheng Yang
KLKeyun Liu
Keyun Liu

19 January 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
Xianqiang BaoXianqiang Bao
Xianqiang Bao
SGShuoxin Gu
Shuoxin Gu
YGYangming Guo
Yangming Guo
CYCheng Yang
Cheng Yang
LSLiwei Shi
Liwei Shi
YJYuhua Jiang
Yuhua Jiang
Remote-controlled vascular interventional robots have great potential for use in minimally invasive vascular surgeries in recent years due to their ability to reduce the occupational risk of surgeons and improve the stability and accuracy of surgical procedures. However, blood vessels will suffer from the damage caused by collision with medical instruments to some extent even though the surgeries are very successful. Moreover, when surgeons perform unsafe operations, the unsafe operations will not only seriously affect surgical safety (or even cause serious complications) but also restrict the continuity of operation. In this article, a multilevel concept for operating force is first introduced into surgical procedures as a reference for the choice and design of operation strategies. Based on this concept, a novel multilevel operation strategy is first proposed to reduce blood vessel damage, ensure surgical safety, and allow for continuous operation. This strategy can remind surgeons about the operative conditions in real-time, reduce collision to blood vessels, and eliminate unsafe operations online. A prototype was fabricated and calibrated through calibration experiments and the performance of the multilevel operation strategy was validated through in vitro and ex vivo experiments. Experimental results demonstrate the engineering effectiveness of the proposed method and motivate the need for further in vivo studies to evaluate improvement on surgical safety.

16 August 2018 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
Xianqiang BaoXianqiang Bao
Xianqiang Bao
SGShuoxin Gu
Shuoxin Gu
NXNan Xiao
Nan Xiao
YLYouxiang Li
Youxiang Li
LSLiwei Shi
Liwei Shi

25 July 2019 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
CYCheng Yang
Cheng Yang
SGShuoxin Gu
Shuoxin Gu
Xianqiang BaoXianqiang Bao
Xianqiang Bao
NXNan Xiao
Nan Xiao
LSLiwei Shi
Liwei Shi
YJYuhua Jiang
Yuhua Jiang