The application of wearable magnetoencephalography using optically-pumped magnetometers has drawn extensive attention in the field of neuroscience. Electroencephalogram system can cover the whole head and reflect the overall activity of a large number of neurons. The efficacy of optically-pumped magnetometer in detecting event-related components can be validated through electroencephalogram results. Multivariate pattern analysis is capable of tracking the evolution of neurocognitive processes over time. In this paper, we adopted a classical Chinese semantic congruity paradigm and separately collected electroencephalogram and optically-pumped magnetometer signals. Then, we verified the consistency of optically-pumped magnetometer and electroencephalogram in detecting N400 using mutual information index. Multivariate pattern analysis revealed the difference in decoding performance of these two modalities, which can be further validated by dynamic/stable coding analysis on the temporal generalization matrix. The results from searchlight analysis provided a neural basis for this dissimilarity at the magnetoencephalography source level and the electroencephalogram sensor level. This study opens a new avenue for investigating the brain’s coding patterns using wearable magnetoencephalography and reveals the differences in sensitivity between the two modalities in reflecting neuron representation patterns.
26 March 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
The magnetoencephalogram (MEG) based on array optically pumped magnetometers (OPMs) has the potential of replacing conventional cryogenic superconducting quantum interference device. Phase synchronization is a common method for measuring brain oscillations and functional connectivity. Verifying the feasibility and fidelity of OPM-MEG in measuring phase synchronization will help its widespread application in the study of aforementioned neural mechanisms. The analysis method on source-level time series can weaken the influence of instantaneous field spread effect. In this paper, the OPM-MEG was used for measuring the evoked responses of 20Hz rhythmic and arrhythmic median nerve stimulation, and the inter-trial phase synchronization (ITPS) and inter-reginal phase synchronization (IRPS) of primary somatosensory cortex (SI) and secondary somatosensory cortex (SII) were analysed. The results find that under rhythmic condition, the evoked responses of SI and SII show continuous oscillations and the effect of resetting phase. The values of ITPS and IRPS significantly increase at the stimulation frequency of 20Hz and its harmonic of 40Hz, whereas the arrhythmic stimulation does not exhibit this phenomenon. Moreover, in the initial stage of stimulation, the ITPS and IRPS values are significantly higher at Mu rhythm in the rhythmic condition compared to arrhythmic. In conclusion, the results demonstrate the ability of OPM-MEG in measuring phase pattern and functional connectivity on source-level, and may also prove beneficial for the study on the mechanism of rhythmic stimulation therapy for rehabilitation.
The human brain undergoes tremendous changes during the first decade of life. The susceptibility of the immature central nervous system to factors such as adverse environments and genetic factors is attributed to its plasticity. Neurodevelopmental disorders (NDDs) occur once the immature brain veers off the typical developmental trajectory. However, little is known about the neurophysiological traits of atypically developing children because it is challenging for them to remain still during recording. Magnetoencephalography (MEG) is a noninvasive neuroimaging technique with high-spatiotemporal resolution. An ultralow magnetic field produced by neural electrical activity can be detected using a highly sensitive whole-head magnetometer array. Current cryogenic SQUID-MEG combined with individual MRI has shown great potential in reflecting neural activity under resting states and during tasks. MEG instrumentation for children is expected to be an effective tool for investigating brain dynamics, which provides neuropsychological evidence for atypical development in communication ability. In this paper, the advantages of pediatric MEG in neurodevelopmental disorder studies are discussed first and compared with those of several noninvasive functional imaging modalities. Existing commercial pediatric MEG systems are summarized based on their respective characteristics and parameters. State-of-the-art newly emerging sensing techniques based on spin-exchange relaxation-free (SERF) along with their application in detecting infants' brain responses are introduced. Recent discoveries on MEG biomarkers in children with NDDs are then summarized concerning disorders that have comorbidities in communication, such as specific language impairment (SLI), autism spectrum disorders (ASD), dyslexia and stuttering. Progress on multimodality research and total-field wearable SERF magnetometers offers insight into the neuropsychological substrates of communication disorders.
Multivariate pattern analysis (MVPA) has played an extensive role in interpreting brain activity, which has been applied in studies with modalities such as functional Magnetic Resonance Imaging (fMRI), Magnetoencephalography (MEG) and Electroencephalography (EEG). The advent of wearable MEG systems based on optically pumped magnetometers (OPMs), i.e., OP-MEG, has broadened the application of bio-magnetism in the realm of neuroscience. Nonetheless, it also raises challenges in temporal decoding analysis due to the unique attributes of OP-MEG itself. The efficacy of decoding performance utilizing multimodal fusion, such as MEG-EEG, also remains to be elucidated. In this regard, we investigated the impact of several factors, such as processing methods, models and modalities, on the decoding outcomes of OP-MEG. Our findings indicate that the number of averaged trials, dimensionality reduction (DR) methods, and the number of cross-validation folds significantly affect the decoding performance of OP-MEG data. Additionally, decoding results vary across modalities and fusion strategy. In contrast, decoder type, resampling frequency, and sliding window length exert marginal effects. Furthermore, we introduced mutual information (MI) to investigate how information loss due to OP-MEG data processing affect decoding accuracy. Our study offers insights for linear decoding research using OP-MEG and expand its application in the fields of cognitive neuroscience.
High temperature on the surface of the OPM-MEG array can introduce physiological noise in MEG measurement and overtemperature will result in scald to the skin of the epicranium. In this paper, an experimentally verified temperature field model of the OPM-MEG array is developed. The main heat sources and heat transmission of the system are analyzed, and temperature field distribution is obtained in detail by using the finite element method (FEM). A more efficient thermal management scheme was proposed which used a water-cooling design to control the sensor array temperature and verify better signal to noise ratio in auditory evoked experiments. The temperature at the bottom of sensor array can be reduced by 17.8°C roughly with water temperature of 15°C which falls within the scope of an acceptable sensible temperature. In auditory evoked experiment, the Euclidean distance between cortex where the N1m component is located and MEG signal positioning result is calculated.The location error is reduced by 9.5 %(left) and 66.9 %(right) due to the temperature control by using water cooling system. The method in this paper provides a theoretical basis for the future multi-channel MEG system design in thermal management.