Sahel Mohammadi Ghalehney

Dr. Sahel Mohammadi Ghalehney

Biomechanics, University of Nebraska at Omaha, Omaha, Nebraska, USA
orcid
Graduate Assistant, Biomechanics PhD Student, University of ...

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Vahid MohammadiVahid Mohammadi
Vahid Mohammadi
Mohammad TajdaniMohammad Tajdani
Mohammad Tajdani
MMMobina Masaei
Mobina Masaei
Sahel Mohammadi GhalehneySahel Mohammadi Ghalehney
Sahel Mohammadi Ghalehney
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Conventional passive ankle foot orthoses (AFOs) have not seen substantial advances or functional improvements for decades, failing to meet the demands of many stakeholders, especially the pediatric population with neurological disorders. Our objective is to develop the first comfortable and unobtrusive powered AFO for children with cerebral palsy (CP), the DE-AFO. CP is the most diagnosed neuromotor disorder in the pediatric population. The standard of care for ankle control dysfunction associated with CP, however, is an unmechanized, bulky, and uncomfortable L-shaped conventional AFO. These passive orthoses constrain the ankle’s motion and often cause muscle disuse atrophy, skin damage, and adverse neural adaptations. While powered orthoses could enhance natural ankle motion, their reliance on bulky, noisy, and rigid actuators like DC motors limits their acceptability. Our innovation, the DE-AFO, emerged from insights gathered during customer discovery interviews with 185 stakeholders within the AFO ecosystem as part of the NSF I-Corps program. The DE-AFO is a biomimetic robot that employs artificial muscles made from an electro-active polymer called dielectric elastomers (DEs) to assist ankle movements in the sagittal planes. It incorporates a gait phase detection controller to synchronize the artificial muscles with natural gait cycles, mimicking the function of natural ankle muscles. This device is the first of its kind to utilize lightweight, compact, soft, and silent artificial muscles that contract longitudinally, addressing traditional actuated AFOs’ limitations by enhancing the orthosis’s natural feel, comfort, and acceptability. In this paper, we outline our design approach and describe the three main components of the DE-AFO: the artificial muscle technology, the finite state machine (the gait phase detection system), and its mechanical structure. To verify the feasibility of our design, we theoretically calculated if DE-AFO can provide the necessary ankle moment assistance for children with CP—aligning with moments observed in typically developing children. To this end, we calculated the ankle moment deficit in a child with CP when compared with the normative moment of seven typically developing children. Our results demonstrated that the DE-AFO can provide meaningful ankle moment assistance, providing up to 69% and 100% of the required assistive force during the pre-swing phase and swing period of gait, respectively.

29 September 2024 in Actuators
Verified
Journal Article
Open access
PDF file
Vahid MohammadiVahid Mohammadi
Vahid Mohammadi
Sahel Mohammadi GhalehneySahel Mohammadi Ghalehney
Sahel Mohammadi Ghalehney
MTMohammad Tajdani
Mohammad Tajdani
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
The recent commercial availability of stacked dielectric elastomer actuators (SDEAs) has unlocked new opportunities for their application as “artificial skeletal muscles” in rehabilitation robots and powered exoskeletons. Composed of multiple layers of thin, elastic capacitors, these actuators present a lightweight, soft, and acoustically noiseless alternative to traditional DC motor actuators commonly used in rehabilitation robotics, thereby enhancing the natural feel of such systems. Building on our previous research, this study aimed to evaluate the most recent version of commercial SDEAs to assess their potential for mechanizing rehabilitation robots. We quantified the stress and strain behavior and stiffness of these actuators in both single and 1 × 3 configurations (with three SDEAs connected in series). The actuators demonstrated the capability to generate up to 25 N of force and 115 KPa, a value surpassing human biceps, with a longitudinal strain measured at about 11%. The significant increase in force generation from 10 N in the previous version to 25 N and displacement from 3.3% to 11% substantially enhances the applicability of this actuator in rehabilitation robotics. SDEAs’ high force generation capability, combined with their strain and stress characteristics comparable to that of human biological muscles, make them ideal alternative actuators for biomimetic robots and applications where actuators must operate in the vicinity of the human body.

11 October 2024 in Physica Scripta
Verified
Journal Article
Open access
Sahel Mohammadi GhalehneySahel Mohammadi Ghalehney
Sahel Mohammadi Ghalehney
MSMohammad Hossein Sadeghi
Mohammad Hossein Sadeghi
HBHamed Barati
Hamed Barati
HGHussain Gharehbaghi
Hussain Gharehbaghi
This study investigates the design and optimization of a porous hip implant to mitigate stress shielding. Initially, the focus was on determining the elastic modulus of a three-dimensional auxetic structure, primarily in the y-direction. Various methods—numerical, analytical, and experimental—were used to assess the elastic properties. Additive manufacturing was employed to create samples, which were then tested for their elastic properties through compression testing. The results revealed a strong correlation between the elastic modulus values obtained from simulations and experimental tests in the y-direction. To further enhance the implant’s performance and reduce stress shielding at the implant-bone interface, a gradient structure was introduced. This gradient design progressively increases the elastic modulus away from the bone contact surfaces, aligning closely with the bone’s modulus at the interface. The elastic modulus of this gradient structure was computed using Abaqus software and validated through analytical methods in MATLAB, with a minimal 4.8% difference between the two approaches, demonstrating high agreement. The application of a genetic algorithm enabled the creation of a porous hip implant tailored to minimize stress shielding throughout its structure. This innovative approach, integrating numerical, analytical, and experimental techniques with gradient structures, holds promise for improving hip implant performance and enhancing patient outcomes by reducing stress-shielding complications.

18 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Vahid MohammadiVahid Mohammadi
Vahid Mohammadi
Sahel Mohammadi GhalehneySahel Mohammadi Ghalehney
Sahel Mohammadi Ghalehney
MTMohammad Tajdani
Mohammad Tajdani
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
The recent commercial availability of stacked dielectric elastomer actuators (SDEAs) has unlocked new opportunities for their application as "artificial skeletal muscles" in rehabilitation robots and powered exoskeletons. Composed of multiple layers of thin, elastic capacitors, these actuators present a lightweight, soft, and acoustically noiseless alternative to traditional DC motor actuators commonly used in rehabilitation robotics, thereby enhancing the natural feel of such systems. Building on our previous research, this study aimed to evaluate the most recent version of commercial SDEAs to assess their potential for mechanizing rehabilitation robots. We quantified the stress and strain behavior and stiffness of these actuators in both single and 1x3 configurations (with three SDEAs connected in series). The actuators demonstrated the capability to generate up to 25 N of force, 103 KPa, a value closely resembling human biceps, with a longitudinal strain measured at about 11%. The significant increase in force generation from 10 N, in the previous version, to 25 N and displacement from 3.3% to 11% substantially enhances the applicability of this actuator rehabilitation robotics. SDEAs' high force generation capability, combined with their strain and stress characteristics comparable to that of human biological muscles make them ideal alternative actuators for biomimetic robots and applications where actuators must operate in the vicinity of the human body.