Mobina Masaei

Ms. Mobina Masaei

Biomechanics, University of Nebraska at Omaha, Omaha, Nebraska, USA
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Vahid MohammadiVahid Mohammadi
Vahid Mohammadi
Mohammad TajdaniMohammad Tajdani
Mohammad Tajdani
MMMobina Masaei
Mobina Masaei
Sahel Mohammadi GhalehneySahel Mohammadi Ghalehney
Sahel Mohammadi Ghalehney
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Conventional passive ankle foot orthoses (AFOs) have not seen substantial advances or functional improvements for decades, failing to meet the demands of many stakeholders, especially the pediatric population with neurological disorders. Our objective is to develop the first comfortable and unobtrusive powered AFO for children with cerebral palsy (CP), the DE-AFO. CP is the most diagnosed neuromotor disorder in the pediatric population. The standard of care for ankle control dysfunction associated with CP, however, is an unmechanized, bulky, and uncomfortable L-shaped conventional AFO. These passive orthoses constrain the ankle’s motion and often cause muscle disuse atrophy, skin damage, and adverse neural adaptations. While powered orthoses could enhance natural ankle motion, their reliance on bulky, noisy, and rigid actuators like DC motors limits their acceptability. Our innovation, the DE-AFO, emerged from insights gathered during customer discovery interviews with 185 stakeholders within the AFO ecosystem as part of the NSF I-Corps program. The DE-AFO is a biomimetic robot that employs artificial muscles made from an electro-active polymer called dielectric elastomers (DEs) to assist ankle movements in the sagittal planes. It incorporates a gait phase detection controller to synchronize the artificial muscles with natural gait cycles, mimicking the function of natural ankle muscles. This device is the first of its kind to utilize lightweight, compact, soft, and silent artificial muscles that contract longitudinally, addressing traditional actuated AFOs’ limitations by enhancing the orthosis’s natural feel, comfort, and acceptability. In this paper, we outline our design approach and describe the three main components of the DE-AFO: the artificial muscle technology, the finite state machine (the gait phase detection system), and its mechanical structure. To verify the feasibility of our design, we theoretically calculated if DE-AFO can provide the necessary ankle moment assistance for children with CP—aligning with moments observed in typically developing children. To this end, we calculated the ankle moment deficit in a child with CP when compared with the normative moment of seven typically developing children. Our results demonstrated that the DE-AFO can provide meaningful ankle moment assistance, providing up to 69% and 100% of the required assistive force during the pre-swing phase and swing period of gait, respectively.

14 October 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
MMMobina Masaei
Mobina Masaei
NZNicole Zahradka
Nicole Zahradka
Khushboo VermaKhushboo Verma
Khushboo Verma
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Progressive gait impairments remain a major challenge for children with cerebral palsy (CP), often limiting independence and quality of life. Although neuromuscular electrical stimulation (NMES) has shown promise for improving gait, most NMES-assisted gait studies in children with CP have targeted only a single muscle. In this exploratory study, we characterized acute biomechanical responses of six children with CP to seven NMES protocols during treadmill walking. The protocols comprised multi-muscle stimulation, single-muscle stimulation, and an individualized physical therapist-derived (PT-derived) condition. Each protocol was compared with a no-stimulation baseline and typically developing (TD) reference data. The primary and secondary outcomes were the Gait Deviation Index (GDI) and Coefficient of Variation (CV), complemented by the targeted outcome measures, including lower-limb joint kinematics using phase-by-phase Dynamic Time Warping (DTW), maximum knee extension, and stride length. We found that the comparison between multi-muscle and single-muscle conditions did not identify a statistically significant difference in GDI. CV analyses showed smaller distances from TD reference values for multi-muscle conditions, although not significant. Stimulation conditions significantly affected maximum knee extension and DTW during loading response at the ankle and pre-swing at the hip; however, no individual condition differed significantly from no stimulation after false discovery rate correction. The PT-derived condition showed favorable directional changes in selected outcomes, but no consistent advantage over the other protocols. These preliminary observations characterize acute response patterns and generate hypotheses for future studies; they do not establish the comparative efficacy of multi-muscle, single-muscle, or individualized NMES protocols.

17 September 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MMMobina Masaei
Mobina Masaei
NZNicole Zahradka
Nicole Zahradka
Khushboo VermaKhushboo Verma
Khushboo Verma
SLSamuel Lee
Samuel Lee
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Progressive gait impairments remain a major challenge for children with cerebral palsy (CP), often limiting independence and quality of life. While neuromuscular electrical stimulation (NMES) shows promise for improving gait, prior studies in this population have largely targeted only a single muscle. To address this gap, we examined multi-muscle versus single-muscle NMES during treadmill walking in six children with CP, comparing seven protocols, including an individualized physical-therapist-derived (PT-derived) protocol against a no-stimulation baseline and typically developing controls. Gait quality was assessed using the Gait Deviation Index (GDI) as the primary outcome, alongside the Coefficient of Variation (CV) and targeted kinematic measures. Results were mixed: group-level GDI differences were not significant, though CV analyses showed multi-muscle conditions produced more consistently favorable gait patterns than single-muscle stimulation. Stimulation condition significantly affected maximum knee extension and Dynamic Time Warping during ankle loading response and hip pre-swing; however, after correction for multiple comparisons, no protocol differed significantly from baseline. The PT-derived condition showed favorable directional trends across several outcomes, though not consistently significant. These preliminary findings suggest multi-muscle, individualized NMES strategies may produce phase- and joint-specific biomechanical effects, but larger studies with better gait-phase detection and longer exposure are needed before drawing clinical conclusions.