Mitsue Miyazaki

Prof. Mitsue Miyazaki

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Drug Metabolism and Pharmacokinetics
Verified
Journal Article
Open access
YYYuki Yamaguchi
Yuki Yamaguchi
TATakeshi Akiyoshi
Takeshi Akiyoshi
GKGo Kawamura
Go Kawamura
AIAyuko Imaoka
Ayuko Imaoka
MMMitsue Miyazaki
Mitsue Miyazaki
HOHisakazu Ohtani
Hisakazu Ohtani
Cytochrome P450 (CYP) 3A4 is one of the major drug-metabolizing enzymes. Genetic variants of CYP3A4 with altered activity are one of the factors responsible for interindividual differences in drug metabolism. Azole antifungals inhibit CYP3A4 to cause clinically significant drug-drug interactions. In the present quantitative study, we investigated the inhibitory effects of three azole antifungals (ketoconazole, voriconazole, and fluconazole) on testosterone metabolism by recombinant CYP3A4 genetic variants (CYP3A4.1 (WT), CYP3A4.2, CYP3A4.7, CYP3A4.16, and CYP3A4.18) and compared them with those previously reported for itraconazole. The inhibition constants (Ki) of ketoconazole, voriconazole, and fluconazole for rCYP3A4.1 were 3.6 nM, 3.2 μM, and 16.1 μM, respectively. The Ki values of these azoles for rCYP3A4.16 were 13.9-, 13.6-, and 6.2-fold higher than those for rCYP3A4.1, respectively, whereas the Ki value of itraconazole for rCYP3A4.16 was 0.54-fold of that for rCYP3A4.1. The other genetic variants had similar effects on the Ki values of the three azoles, whereas a very different pattern was seen for itraconazole. In conclusion, itraconazole has unique characteristics that are distinct from those shared by the other azole anti-fungal drugs ketoconazole, voriconazole, and fluconazole with regard to the influence of genetic variations on the inhibition of CYP3A4.

1 January 2024 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
VMVadim Malis
Vadim Malis
WBWon C. Bae
Won C. Bae
AYAsako Yamamoto
Asako Yamamoto
LMLinda K. McEvoy
Linda K. McEvoy
MMMarin A. McDonald
Marin A. McDonald
MMMitsue Miyazaki
Mitsue Miyazaki
Purpose: Clearance of cerebrospinal fluid (CSF) is important for the removal of toxins from the brain, with implications for neurodegenerative diseases. Imaging evaluation of CSF outflow in humans has been limited, relying on venous or invasive intrathecal injections of contrast agents. The objective of this study was to introduce a novel spin-labeling MRI technique to detect and quantify the movement of endogenously tagged CSF, and then apply it to evaluate CSF outflow in normal humans of varying ages.Methods: This study was performed on a clinical 3-Tesla MRI scanner in 16 healthy subjects with an age range of 19–71 years with informed consent. Our spin-labeling MRI technique applies a tag pulse on the brain hemisphere, and images the outflow of the tagged CSF into the superior sagittal sinus (SSS). We obtained 3D images in real time, which was analyzed to determine tagged-signal changes in different regions of the meninges involved in CSF outflow. Additionally, the signal changes over time were fit to a signal curve to determine quantitative flow metrics. These were correlated against subject age to determine aging effects.Results: We observed the signal of the tagged CSF moving from the dura mater and parasagittal dura, and finally draining into the SSS. In addition, we observed a possibility of another pathway which is seen in some young subjects. Furthermore, quantitative CSF outflow metrics were shown to decrease significantly with age.Conclusion: We demonstrate a novel non-invasive MRI technique identifying two intrinsic CSF clearance pathways, and observe an age-related decline of CSF flow metrics in healthy subjects. Our work provides a new opportunity to better understand the relationships of these CSF clearance pathways during the aging process, which may ultimately provide insight into the age-related prevalence of neurodegenerative diseases.

1 January 2024 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
MMMitsue Miyazaki
Mitsue Miyazaki
VMVadim Malis
Vadim Malis
AYAsako Yamamoto
Asako Yamamoto
JKJirach Kungsamutr
Jirach Kungsamutr
LMLinda K. McEvoy
Linda K. McEvoy
WBWon C Bae
Won C Bae
Purpose: Cerebrospinal fluid (CSF) clearance is essential for maintaining a healthy brain and cognition by removal of metabolic waste from the central nervous system. Physical exercise has been shown to improve human health; however, the effect of physical exercise on intrinsic CSF outflow in humans remains unexplored. The purpose of this study was to investigate intrinsic CSF outflow pathways and quantitative metrics of healthy individuals with active and sedentary lifestyles. In addition, the effect of exercise was investigated among the sedentary subjects before and after 3 weeks of physical activity.Methods: This study was performed on 18 healthy adults with informed consent, using a clinical 3-Tesla MRI scanner. We classified participants into two groups based on reported time spent sitting per day (active group: < 7 hours sitting per day and sedentary group: ≥ 7 hours sitting per day). To elucidate the effect of exercise, sedentary individuals increased their activity to 3.5 hours for 3 weeks.Results: We show that there are two intrinsic CSF egress pathways of the dura mater and lower parasagittal dura (PSD). The adults with an active lifestyle had greater intrinsic CSF outflow metrics than adults with a more sedentary lifestyle. However, after increased physical activity, the sedentary group showed improved CSF outflow metrics. This improvement was particularly notable at the lower PSD, where outflow metrics were highest among the active group.Conclusion: Our findings describe the relationship between physical activity and intrinsic CSF outflow and show a potential selective outflow pathway with increasing physical activity in the lower PSD pathway, potentially from the perivascular space or cortical venous subpial space.

25 June 2024 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
HOHideki Ota
Hideki Ota
YMYoshiaki Morita
Yoshiaki Morita
DVDiana Vucevic
Diana Vucevic
SHSatoshi Higuchi
Satoshi Higuchi
HTHidenobu Takagi
Hidenobu Takagi
MMMitsue Miyazaki
Mitsue Miyazaki

13 February 2020 in Journal of Cellular Physiology
Verified
Journal Article
Closed access
PDF file
TSTomohiko Sato
Tomohiko Sato
DVDiana Vargas
Diana Vargas
KMKakushin Miyazaki
Kakushin Miyazaki
KUKaoru Uchida
Kaoru Uchida
WAWinda Ariyani
Winda Ariyani
NSNoriaki Shimokawa
Noriaki Shimokawa

24 July 2024 in Computation
Verified
Journal Article
Open access
PDF file
DVDiana Vucevic
Diana Vucevic
VMVadim Malis
Vadim Malis
YYYuichi Yamashita
Yuichi Yamashita
AMAnya Mesa
Anya Mesa
TYTomosuke Yamaguchi
Tomosuke Yamaguchi
WBWon C. Bae
Won C. Bae
Isthmic spondylolysis is characterized by a stress injury to the pars interarticularis bones of the lumbar spines and is often missed by conventional magnetic resonance imaging (MRI), necessitating a computed tomography (CT) for accurate diagnosis. We compare MRI techniques suitable for producing CT-like images. Lumbar spines of asymptomatic and low back pain (LBP) subjects were imaged at 3-Tesla with multi-echo ultrashort echo time (UTE) and field echo (FE) sequences followed by simple post-processing of averaging and inverting to depict spinal bones with a CT-like appearance. The contrast-to-noise ratio (CNR) for bone was determined to compare UTE vs. FE and single-echo vs. multi-echo data. Visually, both sequences depicted cortical bone with good contrast; UTE-processed sequences provided a flatter contrast for soft tissues that made them easy to distinguish from bone, while FE-processed images had better resolution and bone–muscle contrast, which are important for fracture detection. Additionally, multi-echo images provided significantly (p = 0.03) greater CNR compared with single-echo images. Using these techniques, progressive spondylolysis was detected in an LBP subject. This study demonstrates the feasibility of using spine bone MRI to yield CT-like contrast. Through the employment of multi-echo UTE and FE sequences combined with simple processing, we observe sufficient enhancements in image quality and contrast to detect pars fractures.