Anya Mesa

Ms. Anya Mesa


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in Computation
Verified
Journal Article
Open access
PDF file
DVDiana Vucevic
Diana Vucevic
VMVadim Malis
Vadim Malis
YYYuichi Yamashita
Yuichi Yamashita
AMAnya Mesa
Anya Mesa
TYTomosuke Yamaguchi
Tomosuke Yamaguchi
WBWon C. Bae
Won C. Bae
Isthmic spondylolysis is characterized by a stress injury to the pars interarticularis bones of the lumbar spines and is often missed by conventional magnetic resonance imaging (MRI), necessitating a computed tomography (CT) for accurate diagnosis. We compare MRI techniques suitable for producing CT-like images. Lumbar spines of asymptomatic and low back pain (LBP) subjects were imaged at 3-Tesla with multi-echo ultrashort echo time (UTE) and field echo (FE) sequences followed by simple post-processing of averaging and inverting to depict spinal bones with a CT-like appearance. The contrast-to-noise ratio (CNR) for bone was determined to compare UTE vs. FE and single-echo vs. multi-echo data. Visually, both sequences depicted cortical bone with good contrast; UTE-processed sequences provided a flatter contrast for soft tissues that made them easy to distinguish from bone, while FE-processed images had better resolution and bone–muscle contrast, which are important for fracture detection. Additionally, multi-echo images provided significantly (p = 0.03) greater CNR compared with single-echo images. Using these techniques, progressive spondylolysis was detected in an LBP subject. This study demonstrates the feasibility of using spine bone MRI to yield CT-like contrast. Through the employment of multi-echo UTE and FE sequences combined with simple processing, we observe sufficient enhancements in image quality and contrast to detect pars fractures.

6 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WBWon C. Bae
Won C. Bae
VMVadim Malis
Vadim Malis
YYYuichi Yamashita
Yuichi Yamashita
AMAnya Mesa
Anya Mesa
DVDiana Vucevic
Diana Vucevic
MMMitsue Miyazaki
Mitsue Miyazaki
Background: Computed tomography (CT) is the preferred imaging modality for bone evaluation of the knee, while MRI of the bone is actively being developed. We present three techniques using short-interval delta ultrashort echo time (δUTE), field echo (FE), and FE with high resolution–deep learning reconstruction (HR–DLR) for direct bone MRI. Methods: Knees of healthy volunteers (n = 5, 3 females, 38 ± 17.2 years old) were imaged. CT-like images were generated by averaging images from multiple echoes and inverting. The bone signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined. Results: The δUTE depicted a cortical bone with high signal intensity but could not resolve trabeculae. In contrast, both the FE and FE HR–DLR images depicted cortical and trabecular bone with high signal. Quantitatively, while δUTE had a good bone SNR of ~100 and CNR of ~40 for the cortical bone, the SNR for the FE HR–DLR was significantly higher (p < 0.05), at over 400, and CNR at over 200. Conclusions: For 3D rendering of the bone surfaces, the δUTE provided better image contrast and separation of bone from ligaments and tendons than the FE sequences. While there still is no MRI technique that provides a perfect CT-like contrast, continued advancement of MRI techniques may provide benefits for specific use cases.

9 September 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
WBWon C. Bae
Won C. Bae
LHLewis Hahn
Lewis Hahn
VMVadim Malis
Vadim Malis
AMAnya Mesa
Anya Mesa
DVDiana Vucevic
Diana Vucevic
MMMitsue Miyazaki
Mitsue Miyazaki
Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) × 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel’s signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p > 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p > 0.2) or vessel width (averaging 4.1 to 4.9 mm; p > 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p < 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.

6 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
WBWon C. Bae
Won C. Bae
AMAnya Mesa
Anya Mesa
VMVadim Malis
Vadim Malis
YKYoshiki Kuwatsuru
Yoshiki Kuwatsuru
KNKatsumi Nakamura
Katsumi Nakamura
MMMitsue Miyazaki
Mitsue Miyazaki
Background: Peripheral artery disease (PAD) is a manifestation of atherosclerosis that affects the extremities, leading to reduced perfusion and functional impairment. Non-contrast magnetic resonance angiography (NC-MRA) provides a safe and quantitative approach for early detection of PAD without the risks associated with contrast agents. The purpose of this study was to demonstrate the application of standard and centric ky-kz FBI techniques for rapid three-station NC-MRA of the entire lower extremity. Methods: This prospective cross-sectional study compared standard three-station fresh blood imaging (sFBI) with centric ky-kz ordered fresh blood imaging (cFBI) sequences in 10 healthy subjects and 3 patients with PAD (age range: 23–79 years; 7 females) using a 3-Tesla magnetic resonance imaging (MRI) system. Both sequences were acquired at the iliac, femoral, and tibial stations. Image quality (0–4 scale), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. Statistical analysis was performed using repeated-measures analysis of variance (ANOVA) with significance set at α = 0.05. Results: Image quality did not differ significantly between sFBI and cFBI (p = 1.0). The iliac station exhibited lower image quality than the femoral station (p < 0.01). In a PAD patient with an iliac stent, cFBI preserved good image quality in the femoral and tibial stations, whereas sFBI was affected by N/2 aliasing artifacts. Both methods failed to visualize the stented iliac segment. Compared to sFBI, cFBI yielded significantly lower SNR (p < 0.01) and CNR (p < 0.001) but reduced total scan time by approximately 40% (468 s vs. 291 s). Conclusions: Three-station non-contrast FBI MRA of the peripheral arteries is feasible. The cFBI sequence substantially shortens scan time without compromising diagnostic image quality, offering practical advantages for clinical implementation, improved patient comfort, and reduced motion artifacts.