Lumbar spine Magnetic Resonance Imaging (MRI) is commonly used for intervertebral disc (IVD) and vertebral body (VB) evaluation during low back pain. Segmentation of these tissues can provide useful quantitative information such as shape and volume. The objective of the study was to determine the performances of Segment Anything Model (SAM) and medical SAM (MedSAM), two “zero-shot” deep learning models, in segmenting lumbar IVD and VB from MRI images and compare against the nnU-Net model. This cadaveric study used 82 donor spines. Manual segmentation was performed to serve as ground truth. Two readers processed the spine MRI using SAM and MedSAM by placing points or drawing bounding boxes around regions of interest (ROI). The outputs were compared against ground truths to determine Dice score, sensitivity, and specificity. Qualitatively, results varied but overall, MedSAM produced more consistent results than SAM, but neither matched the performance of nnU-Net. Mean Dice scores for MedSAM were 0.79 for IVDs and 0.88 for VBs, and significantly higher (each p < 0.001) than those for SAM (0.64 for IVDs, 0.83 for VBs). Both were lower compared to nnU-Net (0.99 for IVD and VB). Sensitivity values also favored MedSAM. These results demonstrated the feasibility of “zero-shot” DL models to segment lumbar spine MRI. While performance falls short of recent models, these zero-shot models offer key advantages in not needing training data and faster adaptation to other anatomies and tasks. Validation of a generalizable segmentation model for lumbar spine MRI can lead to more precise diagnostics, follow-up, and enhanced back pain research, with potential cost savings from automated analyses while supporting the broader use of AI and machine learning in healthcare.
Isthmic spondylolysis results in fracture of pars interarticularis of the lumbar spine, found in as many as half of adolescent athletes with persistent low back pain. While computed tomography (CT) is the gold standard for the diagnosis of spondylolysis, the use of ionizing radiation near reproductive organs in young subjects is undesirable. While magnetic resonance imaging (MRI) is preferable, it has lowered sensitivity for detecting the condition. Recently, it has been shown that ultrashort echo time (UTE) MRI can provide markedly improved bone contrast compared to conventional MRI. To take UTE MRI further, we developed supervised deep learning tools to generate (1) CT-like images and (2) saliency maps of fracture probability from UTE MRI, using ex vivo preparation of cadaveric spines. We further compared quantitative metrics of the contrast-to-noise ratio (CNR), mean squared error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) between UTE MRI (inverted to make the appearance similar to CT) and CT and between CT-like images and CT. Qualitative results demonstrated the feasibility of successfully generating CT-like images from UTE MRI to provide easier interpretability for bone fractures thanks to improved image contrast and CNR. Quantitatively, the mean CNR of bone against defect-filled tissue was 35, 97, and 146 for UTE MRI, CT-like, and CT images, respectively, being significantly higher for CT-like than UTE MRI images. For the image similarity metrics using the CT image as the reference, CT-like images provided a significantly lower mean MSE (0.038 vs. 0.0528), higher mean PSNR (28.6 vs. 16.5), and higher SSIM (0.73 vs. 0.68) compared to UTE MRI images. Additionally, the saliency maps enabled quick detection of the location with probable pars fracture by providing visual cues to the reader. This proof-of-concept study is limited to the data from ex vivo samples, and additional work in human subjects with spondylolysis would be necessary to refine the models for clinical use. Nonetheless, this study shows that the utilization of UTE MRI and deep learning tools could be highly useful for the evaluation of isthmic spondylolysis.
Isthmic spondylolysis is characterized by a stress injury to the pars interarticularis bones of the lumbar spines and is often missed by conventional magnetic resonance imaging (MRI), necessitating a computed tomography (CT) for accurate diagnosis. We compare MRI techniques suitable for producing CT-like images. Lumbar spines of asymptomatic and low back pain (LBP) subjects were imaged at 3-Tesla with multi-echo ultrashort echo time (UTE) and field echo (FE) sequences followed by simple post-processing of averaging and inverting to depict spinal bones with a CT-like appearance. The contrast-to-noise ratio (CNR) for bone was determined to compare UTE vs. FE and single-echo vs. multi-echo data. Visually, both sequences depicted cortical bone with good contrast; UTE-processed sequences provided a flatter contrast for soft tissues that made them easy to distinguish from bone, while FE-processed images had better resolution and bone–muscle contrast, which are important for fracture detection. Additionally, multi-echo images provided significantly (p = 0.03) greater CNR compared with single-echo images. Using these techniques, progressive spondylolysis was detected in an LBP subject. This study demonstrates the feasibility of using spine bone MRI to yield CT-like contrast. Through the employment of multi-echo UTE and FE sequences combined with simple processing, we observe sufficient enhancements in image quality and contrast to detect pars fractures.
Intrinsic cerebrospinal fluid (CSF) dynamics in the brain have been extensively studied, particularly the egress sites of tagged intrinsic CSF in the meninges. Although spinal CSF recirculates within the central nervous system (CNS), we hypothesized that CSF outflows from the lumbar spinal canal. We aimed to visualize and semi-quantify the outflow using non-contrast MRI techniques. We utilized a 3 Tesla clinical MRI with a 16-channel spine coil, employing time–spatial labeling inversion (Time-SLIP) with tag-on and tag-off acquisitions, T2-weighted coronal 2D fluid-attenuated inversion recovery (FLAIR) and T2-weighted coronal 3D centric ky-kz single-shot FSE (cSSFSE). Images were acquired using time–spatial labeling inversion pulse (Time-SLIP) with tag-on and tag-off acquisitions with varying TI periods. Ten healthy volunteers with no known spinal diseases participated. Variations in tagged CSF outflow were observed across different thoracolumbar nerve root segments in all participants. We quantified CSF outflow at all lumbar levels and the psoas region. There was no significant difference among the ROIs for signal intensity. The tagged CSF outflow from the spinal canal is small but demonstrates egress to surrounding tissues. This finding may pave the way for exploring intrathecal drug delivery, understanding of CSF-related pathologies and its potential as a biomarker for peripheral neuropathy and radiculopathy.
Background: Computed tomography (CT) is the preferred imaging modality for bone evaluation of the knee, while MRI of the bone is actively being developed. We present three techniques using short-interval delta ultrashort echo time (δUTE), field echo (FE), and FE with high resolution–deep learning reconstruction (HR–DLR) for direct bone MRI. Methods: Knees of healthy volunteers (n = 5, 3 females, 38 ± 17.2 years old) were imaged. CT-like images were generated by averaging images from multiple echoes and inverting. The bone signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined. Results: The δUTE depicted a cortical bone with high signal intensity but could not resolve trabeculae. In contrast, both the FE and FE HR–DLR images depicted cortical and trabecular bone with high signal. Quantitatively, while δUTE had a good bone SNR of ~100 and CNR of ~40 for the cortical bone, the SNR for the FE HR–DLR was significantly higher (p < 0.05), at over 400, and CNR at over 200. Conclusions: For 3D rendering of the bone surfaces, the δUTE provided better image contrast and separation of bone from ligaments and tendons than the FE sequences. While there still is no MRI technique that provides a perfect CT-like contrast, continued advancement of MRI techniques may provide benefits for specific use cases.
Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) × 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel’s signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p > 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p > 0.2) or vessel width (averaging 4.1 to 4.9 mm; p > 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p < 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.