Andreea-Ioana Nica

Ms. Andreea-Ioana Nica

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in Medicina
Verified
Journal Article
Open access
PDF file
Thomas Josef VoglThomas Josef Vogl
Thomas Josef Vogl
ANAndreea-Ioana Nica
Andreea-Ioana Nica
CBChristian Booz
Christian Booz
Leona S. AlizadehLeona S. Alizadeh
Leona S. Alizadeh
Sven BeckerSven Becker
Sven Becker
Hamzah AdwanHamzah Adwan
Hamzah Adwan
Background and Objectives: This study aimed to evaluate the tumor response relating to and survival benefit of transarterial chemoperfusion (TACP) and transarterial chemoembolization (TACE) in the treatment of patients with unresectable gynecologic tumors who are intolerant of or have a suboptimal response to chemotherapy and radiotherapy. Materials and Methods: Between January 2000 and October 2023, 75 patients diagnosed with gynecologic tumors underwent 213 TACP and 154 TACE procedures. Of these, 33 patients were treated with TACP, 20 were treated with TACE, and 22 received a combination of both therapies. A retrospective evaluation of local tumor response according to Response Evaluation Criteria in Solid Tumors (RECIST) was conducted, and survival rates were determined using the Kaplan–Meier estimator. Results: Of the total 75 patients, 50 (67%) maintained a stable course of disease until the completion of therapy, 10 (13%) had a partial response, 2 (3%) had a complete response following thermal ablation, and 13 (17%) experienced progression. Furthermore, a 6% reduction in the sum of the longest diameters and an 8% reduction in tumor volume were observed. The median overall survival was 16.15 months, while the median progression-free survival was 13.19 months. Conclusions: TACP and TACE are potential treatment options for local tumor control in patients with unresectable gynecologic tumors who are intolerant of or show a poor response to chemotherapy and radiotherapy. However, further investigation and adjustment of treatment protocols are required to improve therapy response and survival outcomes.

28 August 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
MDMirela Dimitrova
Mirela Dimitrova
LULea Barbara Uebelacker
Lea Barbara Uebelacker
TDTommaso D'Angelo
Tommaso D'Angelo
GBGiuseppe Mauro Bucolo
Giuseppe Mauro Bucolo
IYIbrahim Yel
Ibrahim Yel
DODaniel P. Overhoff
Daniel P. Overhoff
Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40–50 keV and 70–80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.

28 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ANAndreea-Ioana Nica
Andreea-Ioana Nica
CBChristian Booz
Christian Booz
GBGiuseppe Mauro Bucolo
Giuseppe Mauro Bucolo
Leona S. AlizadehLeona S. Alizadeh
Leona S. Alizadeh
Thomas Josef VoglThomas Josef Vogl
Thomas Josef Vogl
TDTommaso D'Angelo
Tommaso D'Angelo
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40–55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.