Kristina Hallam

Dr. Kristina Hallam

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Heechul YoonHeechul Yoon
Heechul Yoon
KHKristina Hallam
Kristina Hallam
Changhan YoonChanghan Yoon
Changhan Yoon
SEStanislav Emelianov
Stanislav Emelianov
Super-resolution imaging with moving microbubbles has shown potential in identifying fine details of deep-lying vascular compartments. To image the extravascular targets, the current study has employed nanometer-sized, optically triggered perfluorohexane nanodroplets (PFHnDs). In response to pulsed laser irradiation, the PFHnDs repeatedly vaporize and stochastically recondense, resulting in random changes of ultrasound signals. Our previous study has shown that the stochastic recondensation of the PFHnDs can be used to isolate individual PFHnDs for super-resolution imaging. This study introduces an improved method for super-resolution imaging with ultrafast ultrasound imaging of PFHnDs. The previous method was based on subtraction of two consecutive ultrasound images to detect signals from recondensed, isolated droplets whereas our current method compounds respective multiple pre- and post-recondensation ultrafast ultrasound images prior to subtraction to improve the spatial resolution further. To evaluate the axial and lateral resolutions of our method, we repeatedly imaged a phantom containing PFHnDs using a programmable ultrasound system synchronized with a pulsed laser system. As a result, our method improved the lateral and axial resolutions by 54% and 68%, respectively, over the previous super-resolution imaging approach, indicating that it can be used for localizing extravascular molecular targets with superior accuracy.

29 August 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
KHKristina Hallam
Kristina Hallam
EDEleanor M. Donnelly
Eleanor M. Donnelly
AKAndrei B. Karpiouk
Andrei B. Karpiouk
RHRobin K. Hartman
Robin K. Hartman
SEStanislav Emelianov
Stanislav Emelianov
A major obstacle in the monitoring and treatment of neurological diseases is the blood brain barrier (BBB), a semipermeable barrier that prevents the delivery of many therapeutics and imaging contrast agents to the brain. In this work, we explored the possibility of laser-activated perfluorocarbon nanodroplets (PFCnDs) to open the BBB and deliver agents to the brain tissue. Specifically, near infrared (NIR) dye-loaded PFCnDs comprised of a perfluorocarbon (PFC) core with a boiling point above physiological temperature were repeatedly vaporized and recondensed from liquid droplet to gas bubble under pulsed laser excitation. As a result, this pulse-to-pulse repeated behavior enabled the recurring interaction of PFCnDs with the endothelial lining of the BBB, allowing for a BBB opening and extravasation of dye into the brain tissue. The blood brain barrier opening and delivery of agents to tissue was confirmed on the macro and the molecular level by evaluating Evans Blue staining, ultrasound-guided photoacoustic (USPA) imaging, and histological tissue analysis. The demonstrated PFCnD-assisted pulsed laser method for BBB opening, therefore, represents a tool that has the potential to enable non-invasive, cost-effective, and efficient image-guided delivery of contrast and therapeutic agents to the brain.

1 May 2025 in Radiology
Verified
Journal Article
Closed access
FKFernando U. Kay
Fernando U. Kay
ACArzu Canan
Arzu Canan
VKVishal Kukkar
Vishal Kukkar
KHKeith Hulsey
Keith Hulsey
ASAngelo Scanio
Angelo Scanio
RPRonald M. Peshock
Ronald M. Peshock
On-premises artificial intelligence was accurate in ruling out obstructive coronary artery disease at coronary CT angiography and achieved substantial to near-perfect agreement with human experts based on Coronary Artery Disease Reporting and Data System 2.0 categories for stenosis severity and plaque burden.

6 June 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
KHKristina Hallam
Kristina Hallam
SEStanislav Emelianov
Stanislav Emelianov
The blood brain barrier (BBB), a component of the brain’s natural defense system, is often a roadblock for the monitoring and treatment of neurological disorders. Recently, we introduced a technique to open the blood brain barrier through the use of laser-activated perfluorohexane nanodroplets (PFHnDs), a phase-change nanoagent that undergoes repeated vaporization and recondensation when excited by a pulsed laser. Laser-activated PFHnDs were shown to enable noninvasive and localized opening of the BBB, allowing extravasation of various sized agents into the brain tissue. In this current work, the laser-activated PFHnD-induced BBB opening is further explored. In particular, laser fluence and the number of laser pulses used for the PFHnD-induced BBB opening are examined and evaluated both qualitatively and quantitatively to determine the effect of these parameters on BBB opening. The results of these studies show trends between increased laser fluence and an increased BBB opening as well as between an increased number of laser pulses and an increased BBB opening, however, with limitations on the extent of the BBB opening after a certain number of pulses. Overall, the results of these studies serve as a guideline to choosing suitable laser parameters for safe and effective BBB opening.

1 April 2026 in Radiology
Verified
Journal Article
Closed access
PSPooyan Sahbaee
Pooyan Sahbaee
CDChelsea Dunning
Chelsea Dunning
APAndrew N. Primak
Andrew N. Primak
ESElisabeth Shanblatt
Elisabeth Shanblatt
KHKristina Hallam
Kristina Hallam
JRJuan Carlos Ramirez-Giraldo
Juan Carlos Ramirez-Giraldo
Insights from 458 peer-reviewed clinical publications indicate that photon-counting CT enhances diagnostic accuracy, reader confidence, and dose efficiency in cardiac, thoracic, neurovascular, abdominal, musculoskeletal, and pediatric imaging, with additional benefits for workflow and disease management.

1 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AAAfrouz Ataei
Afrouz Ataei
VVVasantha Vasan
Vasantha Vasan
TSTodd C. Soesbe
Todd C. Soesbe
CBCecelia C. Brewington
Cecelia C. Brewington
ZZZhongxing Zhou
Zhongxing Zhou
LRLiqiang Ren
Liqiang Ren
Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.