BALAJI HARINATHAN

Mr. BALAJI HARINATHAN

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2024 in Asian Spine Journal
Verified
Journal Article
Open access
PDF file
BHBALAJI HARINATHAN
BALAJI HARINATHAN
DJDavidson Jebaseelan
Davidson Jebaseelan
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
AVAditya Vedantam
Aditya Vedantam
Study Design: This study employed a patient-specific finite element model.Purpose: To quantify the effect of anterior and posterior surgical approaches on adjacent segment biomechanics of the patient-specific spine and spinal cord.Overview of Literature: Adjacent segment degeneration (ASD) is a well-documented complication following cervical fusion, typically resulting from accelerated osteoligamentous deterioration and subsequent symptomatic neural compression. Despite the known impact of spinal fusion on adjacent segment biomechanics, comprehensive comparison between anterior and posterior surgical approaches remains elusive. Understanding these biomechanical changes is crucial for predicting and managing ASD, thereby aiding preoperative surgical planning.Methods: Patient-specific finite element modeling (FEM) of the cervical spine and spinal cord were created. Surgical simulation was performed for multi-segment anterior cervical discectomy fusion (ACDF) (C4–C7) and posterior cervical laminectomy with fusion (PCLF) (C5–6 laminectomy and C4–C7 fusion). Physiological motions were simulated by applying a 2 Nm moment and 75 N force.Results: At the superior adjacent segment, the ACDF model exhibited a higher range of motion (ROM) during neck flexion compared to PCLF. Conversely, in neck extension, PCLF showed a higher ROM than ACDF. At the superior adjacent segment, the ACDF model showed greater spinal cord stress during flexion. During extension, PCLF was associated with greater spinal cord stress. At the inferior adjacent segment, ACDF was associated with greater spinal cord stress than PCLF during flexion. At the superior adjacent segment, ACDF also led to increased intradiskal pressure and capsular ligament strain during flexion, whereas PCLF showed these increases during extension.Conclusions: Our findings indicate the differential effect of ACDF and PCLF on biomechanics at the cervical spine’s adjacent segments, with the patient-specific model with ACDF showing greater changes and potential for degeneration. This study highlights the utility of patient-specific FEMs in enhancing surgical decision-making through personalized medicine.

12 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MRMahmudur Rahman
Mahmudur Rahman
PPPeter Palmer
Peter Palmer
BHBALAJI HARINATHAN
BALAJI HARINATHAN
KDKarthik Banurekha Devaraj
Karthik Banurekha Devaraj
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
AVAditya Vedantam
Aditya Vedantam
Cervical laminoplasty is an established motion-preserving procedure for degenerative cervical myelopathy (DCM). However, patients with pre-existing cervical kyphosis often experience inferior outcomes compared to those with straight or lordotic spines. Limited dorsal spinal cord shift in kyphotic spines post-decompression and increased spinal cord tension may contribute to poor neurological recovery and spinal cord injury. This study aims to quantify the biomechanical impact of cervical sagittal alignment on spinal cord stress and strain post-laminoplasty using a validated 3D finite element model of the C2–T1 spine. Three models were created based on the C2–C7 Cobb angle: lordosis (20 degrees), straight (0 degrees), and kyphosis (−9 degrees). Open-door laminoplasty was simulated at C4, C5, and C6 levels, followed by physiological neck flexion and extension. The results showed that spinal cord stress and strain were highest in kyphotic curvature compared to straight and lordotic curvatures across all cervical segments, despite similar segmental ROM. In flexion, kyphotic spines exhibited 103.3% higher stress and 128.9% higher strain than lordotic spines and 16.7% higher stress and 26.8% higher strain than straight spines. In extension, kyphotic spines showed 135.4% higher stress and 241.7% higher strain than lordotic spines and 21.5% higher stress and 43.2% higher strain than straight spines. The study shows that cervical kyphosis leads to increased spinal cord stress and strain post-laminoplasty, underscoring the need to address sagittal alignment in addition to decompression for optimal patient outcomes.

17 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMahmudur Rahman
Mahmudur Rahman
KDKarthik Banurekha Devaraj
Karthik Banurekha Devaraj
OCOmkar Chauhan
Omkar Chauhan
BHBALAJI HARINATHAN
BALAJI HARINATHAN
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
AVAditya Vedantam
Aditya Vedantam
Degenerative cervical myelopathy (DCM) is characterized by progressive neurological dysfunction, yet the contribution of intramedullary stress and strain during neck motion remains unclear. This study used patient-specific finite element models (FEMs) of the cervical spine and spinal cord to examine the relationship between spinal cord biomechanics and neurological dysfunction. Twenty DCM patients (mean age 62.7 ± 11.6 years; thirteen females) underwent pre-surgical MRI-based modeling to quantify von Mises stress and maximum principal strains at the level of maximum spinal cord compression during simulated neck flexion and extension. Pre-surgical functional assessments included hand sensation, dexterity, and balance. During flexion, the mean intramedullary stress and strain at the level of maximum compression were 7.6 ± 3.7 kPa and 4.3 ± 2.0%, respectively. Increased intramedullary strain during flexion correlated with decreased right-hand sensation (r = −0.58, p = 0.014), impaired right-hand dexterity (r = −0.50, p = 0.048), and prolonged dexterity time (r = 0.52, p = 0.039). Similar correlations were observed with intramedullary stress. Patients with severe DCM exhibited significantly greater stress during flexion than those with mild/moderate disease (p = 0.03). These findings underscore the impact of dynamic spinal cord biomechanics on neurological dysfunction and support their potential utility in improving DCM diagnosis and management.

30 August 2024 in International Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
MBMohamad Bakhaidar
Mohamad Bakhaidar
BHBALAJI HARINATHAN
BALAJI HARINATHAN
KDKarthik Banurekha Devaraj
Karthik Banurekha Devaraj
ADAndrew DeGroot
Andrew DeGroot
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
SSSaman Shabani
Saman Shabani
Background Expandable transforaminal lumbar interbody fusion (TLIF) cages could offer an alternative to anterior lumbar interbody fusion (ALIF). Bilateral cage insertion enhances endplate coverage, potentially improving stability and fusion rates and maximizing segmental lordosis. This study aims to compare the biomechanical properties of bilateral expandable TLIF cages to ALIF cages using finite element modeling. Methods We used a validated 3-dimensional finite element model of the lumbar spine. ALIF and TLIF cages were created based on available product data. Our focus was on analyzing spinal motion in the sagittal plane, evaluating forces transmitted through the vertebrae, and comparing an ALIF model with various TLIF cage models. Results The largest TLIF cage model exhibited a 407.9% increase in flexion motion and a 42.1% decrease in extension motion compared with the ALIF cage. The second largest TLIF cages resulted in more flexion motion and less extension motion compared with ALIF, while smaller cages were inferior to ALIF. ALIF cages were associated with increased adjacent segment motion compared with TLIF cages, primarily in extension. Endplate stress analysis revealed higher stress in the ALIF cage model with a more uniform stress distribution. Conclusion ALIF cages excel in stabilizing L5 to S1 during flexion, while largest TLIF cages offer superior stability in extension. Large bilateral TLIF cages may provide biomechanical stability comparable to ALIF, especially in extension and could potentially reduce the risk of adjacent segment disease with lower adjacent segment motion. Level of Evidence 5.

3 October 2023 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Closed access
PDF file
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
BHBALAJI HARINATHAN
BALAJI HARINATHAN
AVAditya Vedantam
Aditya Vedantam

21 November 2024 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Closed access
PDF file
NYNarayan (Narayan Yoganandan
Narayan (Narayan Yoganandan
KSKarthik Somasundaram
Karthik Somasundaram
BHBALAJI HARINATHAN
BALAJI HARINATHAN
KDKarthik Banurekha Devaraj
Karthik Banurekha Devaraj
ASAlok Shah
Alok Shah
BMB. Joseph McEntire
B. Joseph McEntire