Afroditi Ntziouni

Dr. Afroditi Ntziouni

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Applied Spectroscopy
Verified
Journal Article
Closed access
ANAfroditi Ntziouni
Afroditi Ntziouni
JTJames Thomson
James Thomson
IXIoannis Xiarchos
Ioannis Xiarchos
XLXiang Li
Xiang Li
MBMiguel A. Bañares
Miguel A. Bañares
EDEnrique Lozano Diz
Enrique Lozano Diz
Over the past decades Raman spectroscopy has been extensively used both on an industrial and academic level. This has resulted in the development of numerous specialized Raman techniques and Raman active products, which in turn has led to the adoption and development of standards and norms pertaining to Raman unit’s calibration, performance validation, and interoperability. Purpose of the present review is to list, classify, and engage in a comprehensive analysis of the different standards, guides, and practices relating to Raman spectroscopy. Primary aim of the review is to consider the commonalities and conflicts between these standards and norms and to identify any missing aspects. Standardization in the field of Raman spectroscopy is dominated by the work of American institutions, namely, the American Society of Testing Materials (ASTM or ASTM International), with several active standards in place pertaining to terminology, calibration, multivariate analysis, and specific applications, and the National Institute of Standards and Technology (NIST), providing numerous certified reference materials, referred to as standard reference materials. The industrial application of Raman spectroscopy is dominated by the pharmaceutical industry. As such, pharmacopoeias provide not only important information in relation to pharmaceutical-related applications of Raman spectroscopy, but also invaluable insight, into the basic principles of Raman spectroscopy and important aspects that include calibration, validation, measurement, and chemometric analysis processes, usually by referring to ASTM and NIST standards. Given the fact that Raman spectroscopy is a modern and innovative field, the standardization processes are complex and constantly evolving. Despite the seemingly high number of existing standards, the standardization landscape is incomplete and has not been modernized according to the developments in Raman spectroscopy techniques in recent years. This is evident by the lack of protocols for numerous areas as well as by the fact that some of the existing standards have not been updated to reflect the advances in the technique. Therefore, it is important for the Raman community to actively engage in and contribute to a modernization process that will result in updating existing and introducing new terms, protocols, and guides. Indeed, the development of optimized common standards would be extremely beneficial and would further foster the development and application of Raman spectroscopy techniques, most notably those of surface enhanced Raman spectroscopy and low-resolution portable analyzers.

3 June 2023 in Carbon
Verified
Journal Article
Closed access
NANikolaos D. Adamopoulos
Nikolaos D. Adamopoulos
NTNikos G. Tsierkezos
Nikos G. Tsierkezos
ANAfroditi Ntziouni
Afroditi Ntziouni
FZFu Zhang
Fu Zhang
MTMauricio Terrones
Mauricio Terrones
Konstantinos KordatosKonstantinos Kordatos
Konstantinos Kordatos

11 February 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
NDNomxolisi R. Dywili
Nomxolisi R. Dywili
ANAfroditi Ntziouni
Afroditi Ntziouni
CIChinwe Ikpo
Chinwe Ikpo
MNMiranda Ndipingwi
Miranda Ndipingwi
NHNtuthuko W. Hlongwa
Ntuthuko W. Hlongwa
EIEmmanuel Iwuoha
Emmanuel Iwuoha
Graphene oxide (GO) decorated with silver (Ag), copper (Cu) or platinum (Pt) nanoparticles that are anchored on dodecylbenzene sulfonic acid (DBSA)-doped polyaniline (PANI) were prepared by a simple one-step method and applied as novel materials for high performance supercapacitors. High-resolution transmission electron microscopy (HRTEM) and high-resolution scanning electron microscopy (HRSEM) analyses revealed that a metal-decorated polymer matrix is embedded within the GO sheet. This caused the M/DBSA–PANI (M = Ag, Cu or Pt) particles to adsorb on the surface of the GO sheets, appearing as aggregated dark regions in the HRSEM images. The Fourier transform infrared (FTIR) spectroscopy studies revealed that GO was successfully produced and decorated with Ag, Cu or Pt nanoparticles anchored on DBSA–PANI. This was confirmed by the appearance of the GO signature epoxy C–O vibration band at 1040 cm−1 (which decreased upon the introduction of metal nanoparticle) and the PANI characteristic N–H stretching vibration band at 3144 cm−1 present only in the GO/M/DBSA–PANI systems. The composites were tested for their suitability as supercapacitor materials; and specific capacitance values of 206.4, 192.8 and 227.2 F·g−1 were determined for GO/Ag/DBSA–PANI, GO/Cu/DBSA–PANI and GO/Pt/DBSA–PANI, respectively. The GO/Pt/DBSA–PANI electrode exhibited the best specific capacitance value of the three electrodes and also had twice the specific capacitance value reported for Graphene/MnO2//ACN (113.5 F·g−1). This makes GO/Pt/DBSA–PANI a very promising organic supercapacitor material.

26 August 2025 in Inorganics
Verified
Journal Article
Open access
PDF file
AZAdamantia Zourou
Adamantia Zourou
ANAfroditi Ntziouni
Afroditi Ntziouni
AKAlexandra Karagianni
Alexandra Karagianni
NANiyaz AlizadehKordestani
Niyaz AlizadehKordestani
NANikolaos Argirusis
Nikolaos Argirusis
Christos ArgirusisChristos Argirusis
Christos Argirusis
Carbon dots (CDs), a rapidly emerging class of zero-dimensional (0-D) nanomaterials with small particle sizes (<10 nm), have garnered significant scientific interest owing to their exceptional physicochemical properties, non-toxicity, low-cost synthesis, and versatile applications. In recent years, the combination of various inorganic photocatalysts (e.g., metal oxides, metal chalcogenides, metal oxyhalides, MXenes, non-metallic semiconductors) with CDs has gained momentum as a promising strategy to enhance their photocatalytic efficiency. By incorporating CDs, researchers have addressed fundamental challenges in photocatalytic systems, including limited light absorption range, rapid electron–hole recombination rate, low quantum efficiency, etc. The present review is focused on the most recent developments in CDs-based heterostructures for advanced photocatalytic applications, particularly in the field of environmental remediation, providing a comprehensive overview of emerging strategies, synthesis approaches, and the resulting enhancements in photocatalytic water treatment applications.

24 April 2025 in Applied Spectroscopy
Verified
Journal Article
Open access
DLDirk Lellinger
Dirk Lellinger
JTJames Thomson
James Thomson
NCNicolas Coca-Lopez
Nicolas Coca-Lopez
ANAfroditi Ntziouni
Afroditi Ntziouni
NNNikolaos Nikoloudakis
Nikolaos Nikoloudakis
EDEnrique Lozano Diz
Enrique Lozano Diz
Raman spectroscopy is a powerful characterization technique with increasing applications that would greatly benefit from data harmonization. Several standards deal with calibration in Raman spectroscopy, but no detailed procedure covers the complete calibration of an instrument, including both spectral axes, from reference material spectra generation to data processing. Moreover, the type of reference materials, the quality of the recorded spectra and the choice of the fitting functions are critical for obtaining precise and reliable reference data for calibration. This report describes the challenges and importance of peak fitting for Raman signal calibration based on an interlaboratory study with 10 different instruments. Spectra of neon emission, silicon, calcite, and polystyrene were fitted using common peak shapes, observing that Gaussian, Pearson IV, Voigt, and Voigt shapes are preferred for these materials, respectively. An analysis of the effect on the fitting of the signal-to-noise ratio (S/N) recommends a minimum value of 100 for a Raman peak if it should be used to calibrate a Raman instrument. Some factors that might affect the peak shape of the Raman signal, such as the physical and chemical properties of the sample, the nature of the electronic transitions, the instrument response and the spectral resolution are discussed. The results highlight the role of peak fitting analysis in improving the quality and reliability of Raman spectra calibration and, thus, enhancing data transfer and comparability, especially for handheld and portable Raman analyzers, as well as applications based on quantification, multivariate data analysis, and other complex processing steps.

1 November 2021 in Ceramics International
Verified
Journal Article
Closed access
GKGeorgios Konstantopoulos
Georgios Konstantopoulos
EFEleni Fotou
Eleni Fotou
ANAfroditi Ntziouni
Afroditi Ntziouni
Konstantinos KordatosKonstantinos Kordatos
Konstantinos Kordatos
CCCostas A. Charitidis
Costas A. Charitidis