Electromagnetic tracking (EMT) can benefit image-guided interventions in cases where line of sight is unavailable. However, EMT can suffer from electromagnetic distortion in the presence of metal instruments. Metal instruments are widely used in laparoscopic surgery, ENT surgery, arthroscopy and many other clinical applications. In this work, we investigate the feasibility of tracking such metal instruments by placing the inductive sensor within the instrument shaft. We propose a magnetostatic model of the field within the instrument, and verify the results experimentally for frequencies from 6 kHz to 60 kHz. The impact of the instrument’s dimensions, conductivity and transmitting field frequency is quantified for ranges representative of typical metal instruments used in image-guided interventions. We then performed tracking using the open-source Anser EMT system and quantify the error caused by the presence of the rod as a function of the frequency of the eight emitting coils for the system. The work clearly demonstrates why smaller tool diameters (less than 8 mm) are less susceptible to distortion, as well as identifying optimal frequencies (1 kHz to 2 kHz) for transmitter design to minimise for distortion in larger instruments.
Flexible medical devices require accurate realtime shape feedback during minimally invasive procedures. Conventional fluoroscopic imaging, while used, is limited to 2-D views and exposes users to ionizing radiation. Fiber Bragg grating (FBG) sensing provides a radiation-free alternative but demands complex and costly systems. A purely electromagnetic approach is introduced that uses three uniaxial inductive sensors connected in series, which reduces wiring complexity by requiring only two conductors, regardless of sensor count. This series-connected sensor configuration substantially reduces wiring complexity and acquisition hardware demands; however, it necessitates greater field generation requirements and incurs longer solver runtimes. A lumped parameter model for series-connected sensors is introduced and validated experimentally through impedance measurements, demonstrating minimal amplitude and phase distortion below 10 kHz. The open-source Anser electromagnetic tracking (EMT) platform is extended by using three planar field generators (totaling 24 coils) and implementing a novel objective function that simultaneously estimates the position and orientation of three series sensors. Static accuracy evaluations conducted over a volume of 200 mm × 200 mm × 100 mm yielded mean errors (MEs) below 2.2 mm, while MEs in dynamic assessments were below 1.2 mm. These results constitute an initial step toward compact and accurate shape sensing for flexible catheters in endovascular interventions.