Electromagnetic tracking (EMT) of surgical tools is used for image-guided navigation in minimally invasive interventions. Calibration of the tracker position and orientation is a fundamental task to correct systematic errors. This article explores the effect of metallic distortion on the open hardware Anser EMT system and describes a newly developed approach for volume calibration of the magnetic field model. The technique is also applied to effectively map the field in the presence of magnetic shields that can be used to reduce electromagnetic distortions passively. Unlike calibration techniques commonly found in literature, which aim to correct the tracking position error, our method can reconstruct an analytical magnetic field model starting from a reduced amount of scattered data. This way, a faster convergence of the solver algorithm is obtained, and EMT position and orientation errors are inherently corrected. The new modelling technique was applied to generate a new, undistorted magnetic field model for Anser EMT, to demonstrate the effectiveness of passive shielding, and to compensate for the distortion introduced by a commercial fluoroscopy C-arm. Furthermore, the concept of a real-time distortion compensation technique is expressed based on the modelling method presented in this article. For all the experiments, sub-millimeter errors were obtained after calibration, which may meet the needs of most endoscopic and surgical navigation tasks.
3 April 2024 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents a compact and low-cost on-chip sensor and readout circuit. The sensor achieves high-resolution 5-degrees-of-freedom (DoF) tracking (x, y, z, yaw, and pitch). With the help of an external wire wound sensor, it can also achieve high-resolution 6-degrees-of-freedom (DoF) tracking (x, y, z, yaw, pitch, and roll angles). The sensor uses low-frequency magnetic fields to detect the position and orientation of instruments, providing a viable alternative to using X-rays in image-guided surgery. To measure the local magnetic field, a highly miniaturised on-chip magnetic sensor capable of sensing the magnetic field has been developed incorporating an on-chip magnetic sensor coil, analog-front end, continuous-time ΔΣ analog-to-digital converter (ADC), LVDS transmitter, bandgap reference, and voltage regulator. The microchip is fabricated using 65 nm CMOS technology and occupies an area of 1.06 mm2, the smallest reported among similar designs to the best of our knowledge. The 5-DoF system accurately navigates with a precision of 1.1 mm within the volume-of-intrest (VOI) of 15×15×15 cm 3 . The 6-DoF system achieves a navigation accuracy of 0.8 mm and an angular error of 1.1 degrees in the same VOI. These results were obtained at a 20 Hz update rate in benchtop characterisation. The prototype sensor demonstrates accurate position tracking in real-life pre-clinical in-vivo settings within the porcine lung of a live swine, achieving a reported worst-case registration accuracy of 5.8 mm.
SignificanceConventional ultrasound-guided vascular access procedures are challenging due to the need for anatomical understanding, precise needle manipulation, and hand–eye coordination. Recently, augmented reality (AR)-based guidance has emerged as an aid to improve procedural efficiency and potential outcomes. However, its application in pediatric vascular access has not been comprehensively evaluated.AimWe developed an AR ultrasound application, HoloUS, using the Microsoft HoloLens 2 to display live ultrasound images directly in the proceduralist’s field of view. We presented our evaluation of the effect of using the Microsoft HoloLens 2 for point-of-care ultrasound (POCUS)-guided vascular access in 30 pediatric patients.ApproachA custom software module was developed on a tablet capable of capturing the moving ultrasound image from any ultrasound machine’s screen. The captured image was compressed and sent to the HoloLens 2 via a hotspot without needing Internet access. On the HoloLens 2, we developed a custom software module to receive, decompress, and display the live ultrasound image. Hand gesture and voice command features were implemented for the user to reposition, resize, and change the gain and the contrast of the image. We evaluated 30 (15 successful control and 12 successful interventional) cases completed in a single-center, prospective, randomized study.ResultsThe mean overall rendering latency and the rendering frame rate of the HoloUS application were 139.30 ms (σ=32.02 ms) and 30 frames per second, respectively. The average procedure completion time was 17.3% shorter using AR guidance. The numbers of puncture attempts and needle redirections were similar between the two groups, and the number of head adjustments was minimal in the interventional group.ConclusionWe presented our evaluation of the results from the first study using the Microsoft HoloLens 2 that investigates AR-based POCUS-guided vascular access in pediatric patients. Our evaluation confirmed clinical feasibility and potential improvement in procedural efficiency.
Electromagnetic tracking is essential in surgical navigation without line of sight and to reduce use of harmful radiation-based imaging. The inductive sensors used in current electromagnetic tracking systems are small, often less than a millimetre in diameter, but the need for a wired connection from the sensor to the control unit can cause obstructions and complicate the surgical field. This work introduces a novel wireless method of tracking electromagnetic sensors with immediate applications intended to streamline surgical workflows. Wireless electromagnetic 6 degree-of-freedom sensor nodes were designed and manufactured with an intended use as a patient mounted registration device. The battery-powered prototype device was shown to have a position and orientation trueness of 0.84 mm and 0.7∘, respectively, over a tracking volume of 40 × 40 × 35 cm. The sensor node performs analog and digital signal processing and uses Bluetooth low energy to transmit the sensor data at a 25 Hz refresh rate. The Bluetooth-based wireless electromagnetic sensors nodes developed in this work have comparable performance to standard wired sensors and were tested in both a static volume characterization and a dynamic ex-vivo lung model. The work in this paper is based on the open-source Anser electromagnetic tracking system, although the approach can be generalised to any tracking system. Wireless electromagnetic tracking offers the potential to introduce computer-assisted navigation in surgical procedures where wired sensors were previously infeasible.
29 June 2023 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Electromagnetic tracking (EMT) is beneficial in image-guided interventions to reduce the use of ionising radiation-based imaging techniques. Enabling wirelessly tracked sensors will increase the usability of these systems for catheter tracking and patient registration systems. This work introduces a novel method of wirelessly transmitting sensor data using a frequency modulation (FM) radio. Methods: The proposed technique was tested using the open-source Anser EMT system. An electromagnetic sensor was connected in parallel to an FM transmitter prototype and wired directly to the Anser system for comparison. The performance of the FM transmitter was evaluated on a grid of 125 test points using an optical tracking system as a gold standard. Results: An average position accuracy of 1.61 ± 0.68 mm and angular rotation accuracy of 0.04° for the FM transmitted sensor signal was obtained over a 30 cm × 30 cm × 30 cm volume, in comparison with the 1.14 ± 0.80 mm, 0.04° accuracy previously reported for the Anser system. The FM transmitted sensor signal had an average resolved position precision of 0.95 mm while the directly wired signal was found to have an average precision of 1.09 mm. A very low frequency ( $$\sim $$ 5 mHz) oscillation in the wirelessly transmitted signal was observed and compensated for by performing a dynamic scaling of the magnetic field model used for solving the sensor pose. Conclusions: We demonstrate that FM transmission of an electromagnetic sensor signal can be used to achieve similar tracking performance to a wired sensor. FM transmission for wireless EMT is a viable alternative to digital sampling and transmission over Bluetooth. Future work will create an integrated wireless sensor node using FM communication that is compatible with existing EMT systems.
Electromagnetic tracking (EMT) can benefit image-guided interventions in cases where line of sight is unavailable. However, EMT can suffer from electromagnetic distortion in the presence of metal instruments. Metal instruments are widely used in laparoscopic surgery, ENT surgery, arthroscopy and many other clinical applications. In this work, we investigate the feasibility of tracking such metal instruments by placing the inductive sensor within the instrument shaft. We propose a magnetostatic model of the field within the instrument, and verify the results experimentally for frequencies from 6 kHz to 60 kHz. The impact of the instrument’s dimensions, conductivity and transmitting field frequency is quantified for ranges representative of typical metal instruments used in image-guided interventions. We then performed tracking using the open-source Anser EMT system and quantify the error caused by the presence of the rod as a function of the frequency of the eight emitting coils for the system. The work clearly demonstrates why smaller tool diameters (less than 8 mm) are less susceptible to distortion, as well as identifying optimal frequencies (1 kHz to 2 kHz) for transmitter design to minimise for distortion in larger instruments.