Iontronic pressure sensors are promising in robot haptics because they can achieve high sensing performance using nanoscale electric double layers (EDLs) for capacitive signal output. However, it is challenging to achieve both high sensitivity and high mechanical stability in these devices. Iontronic sensors need microstructures that offer subtly changeable EDL interfaces to boost sensitivity, while the microstructured interfaces are mechanically weak. Here, we embed isolated microstructured ionic gel (IMIG) in a hole array (28 × 28) of elastomeric matrix and cross-link the IMIGs laterally to achieve enhanced interfacial robustness without sacrificing sensitivity. The embedded configuration toughens and strengthens the skin by pinning cracks and by the elastic dissipation of the interhole structures. Furthermore, cross-talk between the sensing elements is suppressed by isolating the ionic materials and by designing a circuit with a compensation algorithm. We have demonstrated that the skin is potentially useful for robotic manipulation tasks and object recognition.
2 July 2024 in Proceedings of the National Academy of Sciences
Artificial skins or flexible pressure sensors that mimic human cutaneous mechanoreceptors transduce tactile stimuli to quantitative electrical signals. Conventional trial-and-error designs for such devices follow a forward structure-to-property routine, which is usually time-consuming and determines one possible solution in one run. Data-driven inverse design can precisely target desired functions while showing far higher productivity, however, it is still absent for flexible pressure sensors because of the difficulties in acquiring a large amount of data. Here, we report a property-to-structure inverse design of flexible pressure sensors, exhibiting a significantly greater efficiency than the conventional routine. We use a reduced-order model that analytically constrains the design scope and an iterative “jumping-selection” method together with a surrogate model that enhances data screening. As an exemplary scenario, hundreds of solutions that overcome the intrinsic signal saturation have been predicted by the inverse method, validating for a variety of material systems. The success in property design on multiple indicators demonstrates that the proposed inverse design is an efficient and powerful tool to target multifarious applications of flexible pressure sensors, which can potentially advance the fields of intelligent robots, advanced healthcare, and human–machine interfaces.
Implanted pressure sensors can provide pressure information to assess localized health conditions of specific tissues or organs, such as the intra-articular pressure within knee joints. However, the prerequisites for implanted sensors pose greater challenges than those for wearables or for robots: aside from biocompatibility and tissue-like softness, they must also exhibit humidity-insensitivity and high pressure-resolution across a broad pressure spectrum. Iontronic sensors can provide superior sensing properties, but they undergo property degradation in wet environments due to the hygroscopic nature of their active component, ionogels. Herein, we introduce a humidity-insensitive iontronic sensor array based on a hydrophobic and tough ionogel polymerized in a hydrophobicity transition yielding two hydrophobic phases: a soft liquid-rich phase enhancing ionic conductivity and ductility, and a stiff polymer-rich phase contributing to superior toughness. We demonstrate the in vivo implantation of these sensor arrays to monitor real-time intra-articular pressure distribution in a sheep model, while assessing knee flexion with angular resolution of 0.1° and level pressure resolution of 0.1%. We anticipate that this sensor array will find applications in various orthopedic surgeries and implantable medical devices.
Soil degradation threatens agricultural productivity and food supply, leading to hunger issues in some developing regions. To address this challenge, we developed a low-cost, highly efficient, and long-term stable soil improvement method. We chose polyvinyl alcohol (PVA), a commercially available polymer that is safe and non-degradable, to serve as a soil adhesive. We mixed PVA solution into the soil and applied a drying treatment to enhance the bonding between PVA and the soil, achieving highly water-stable soil. This PVA-stabilized soil exhibits low bulk density, high porosity, and high permeability, making it an ideal substrate for planting. In a germination test, the PVA-stabilized soil revealed a higher germination rate and growth rate compared to those of the non-treated soil. We believe this simple and efficient soil improvement method can restore degraded soil and contribute to sustainable agriculture.
A novel fingertip pulse sensor is developed based on an iontronic pressure sensor with high sensitivity and linearity over a wide range, which could be applied for assessing diverse cardiovascular status with high reliability.