Zsombor Márton Mohácsi

Mr. Zsombor Márton Mohácsi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
AMAndras Marton
Andras Marton
ZMZsombor Márton Mohácsi
Zsombor Márton Mohácsi
DBDecsi Balázs
Decsi Balázs
BCBalázs Csillag
Balázs Csillag
JBJulia Balog
Julia Balog
György Tibor BaloghGyörgy Tibor Balogh
György Tibor Balogh
Background: Building extensive drug candidate libraries as early in the development pipeline as possible, with high-throughput in vitro absorption, distribution, metabolism, and excretion (ADME) profiling, is crucial for the selection of lead compounds to guide subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high-throughput LC-MS/MS (liquid chromatography tandem mass spectrometry) techniques to meet with the lead profiling demands. Laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS) is a quick and efficient technique for characterizing complex biological samples without laborious sample preparation. Objective: In this study, using an automated LA-REIMS well plate reader, achieving an 8 s per sample measurement time, the oxidative metabolic stability of active drug agents was assessed using biomimetic metalloporphyrin-based oxidative model reactions. Results: The results obtained using the novel LA-REIMS-based protocol were compared to and corroborated by those obtained using conventional HPLC-UV-MS (high performance liquid chromatography with ultra-violet detection coupled with mass spectrometry) measurements. Conclusions: LA-REIMS emerges as a promising technique, demonstrating potential suitability for semi-quantitative high-throughput metabolic stability in an optimized solvent environment.

12 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
AMAndras Marton
Andras Marton
ZMZsombor Márton Mohácsi
Zsombor Márton Mohácsi
DBDecsi Balázs
Decsi Balázs
BCBalázs Csillag
Balázs Csillag
JBJulia Balog
Julia Balog
György Tibor BaloghGyörgy Tibor Balogh
György Tibor Balogh
It is an utmost importance to characterize drug candidates as early in the development pipeline as possible. Appropriate application of the emerging high throughput analytical techniques unlocks the opportunities to obtain experimental data for in vitro absorption, distribution, metabolism and elimination (ADME) profiling of large compound libraries which is crucial for selection of lead compounds. In an usual scenario, only one drug candidate will be selected from thousands of early compounds based on several stability and screening results. A high to medium throughput screening approaches could significantly accelerates the subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high throughput LC-MS/MS techniques to meet with the lead profiling demands. In this study presented an innovative experimental approach that can offer a refreshing alternative. Laser Assisted Rapid Evaporative Ionization Mass Spectrometry (LA-REIMS) is a quick and efficient method for characterizing complex biological samples without laborious sample preparation and chemical separation. Therefore, using an automated LA-REIMS well plate reader as fast as 8 seconds per sample, we assessed the oxidative metabolic stability of active agents using biomimetic metalloporphyrin-based oxidative model reactions at various pH for commercially available drug substances and compared stability measurements with traditional HPLC-DAD-MS results.

27 November 2025 in Molecular Catalysis
Verified
Journal Article
Closed access
SSSára Spátay
Sára Spátay
VHVencel Hahn
Vencel Hahn
DSDorka Szegedi
Dorka Szegedi
BÁBálint Árpád Ádám
Bálint Árpád Ádám
ZMZsombor Márton Mohácsi
Zsombor Márton Mohácsi
AGAdam Golcs
Adam Golcs